This describes the Z-Wave device WT00Z-1, manufactured by Linear Corp with the thing type UID of linear_wt00z1_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The WT00Z-1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Radio Frequency (RF) Controlled, 120 VAC, Wall Mounted Transmitter
Tap either the top or bottom of the WT00Z-1 once.
You must first “RESET UNIT” with your controller to remove it from the network. Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. If removed from a group, it functions as a repeater (only). “RESET UNIT” removes it completely from the network.
The following table summarises the channels available for the WT00Z-1 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 18 configuration parameters available in the WT00Z-1. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Dim Start Level | Set Ignore Start Level Bit When Transmitting Dim Commands |
2 | Suspend Group 4 | Suspend Group 4 |
3 | Night Light | Relationship between LED and status of devices in Group 1 |
4 | Invert Switch | Setting the relationship between the top of the transmitter to ON or OFF |
5 | Ignore start level when recieving dim commands | Ignore start level when recieving dim commands |
7 | ON/OFF dim rate | dim step parameter valid values: 1-99 |
8 | ON/OFF dim rate | dim timer parameter valid values: 1-255 |
9 | Local control dim rate | dim step parameter valid values: 1-99 |
10 | Local control dim rate | dim timer parameter valid values: 1-255 |
11 | ALL ON/ ALL OFF dim rate | dim step parameter valid values: 1-99 |
12 | ALL ON/ ALL OFF dim rate | dim timer parameter valid values: 1-255 |
13 | Disable group 4 during a dim command | Disable group 4 during a dim command |
14 | Enable Shade Control Group 2 | The switch can control shade control devices if this parameter is set to 1. |
15 | Enable Shade Control Group 3 | The switch can control shade control devices if this parameter is set to 1. |
16 | Enable Shade Control Group 1 | The switch can control shade control devices if this parameter is set to 1. |
19 | LED Transmission Indication | LED Transmission Indication |
20 | Poll: minutes | Frequency that WT00Z-1 will poll first node in Group 1 |
21 | Poll first node in group 1 | Activate/Deactivate polling of first node in Group 1 |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Set Ignore Start Level Bit When Transmitting Dim Commands The WT00Z-1 can send Dim commands to Z-Wave enabled dimmers.The Dim command has a start level embedded in it. A dimmer receivingthis command will start dimming from that start level. However, thecommand can be sent so that the dimmer ignores the start level andinstead starts dimming from its current level. By default, the WT00Z-1sends the command so that the dimmer will start dimming from itscurrent dim level rather than the start level embedded in the command.To change this, simply set the configuration parameter to 0.
**• Parameter No: 1• **
**Length: 1 Byte• **
Valid Values = 0 or 1 (default 1)
NOTE:
Any ACT Z-Wave enabled dimmers have the configuration optionto ignore the start level no matter how you configure the WT00Z-1 The following option values may be configured -:
Value | Description |
---|---|
0 | Use Start Level |
1 | Ignore Start Level |
The manufacturer defined default value is 1
(Ignore Start Level).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Suspend Group 4 You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “un-associating” those devices from the group. Setting parameter 2 to the value of 1 will stop the WT00Z-1 from transmitting to devices that are “associated” into Group 4.
• Parameter No: 2•
** Length: 1 **
Byte• Valid Values = 0 or 1 (default 0 The following option values may be configured -:
Value | Description |
---|---|
0 | Enable Group 4 |
1 | Disable Group 4 |
The manufacturer defined default value is 0
(Enable Group 4).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Relationship between LED and status of devices in Group 1 The LED on the WT00Z-1 will by default, turn ON when the status of the devices in Group 1 is ON. To make the LED turn ON when the status of Group 1 is OFF set this parameter to a value of 1.
**Parameter No: 3• **
**Length: 1 Byte• **
Valid Values = 0 or 1 (default 0 The following option values may be configured -:
Value | Description |
---|---|
0 | On when load is on |
1 | On when load is off |
The manufacturer defined default value is 0
(On when load is on).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Setting the relationship between the top of the transmitter to ON or OFF To change the top of the transmitter to OFF and the bottom of the transmitter to ON, set parameter 4 to 1.
To change back to original settings, set this parameter to the value of 0.
Parameter No: 4
Length: 1 Byte
Valid Values = 0 or 1 (default 0) The following option values may be configured -:
Value | Description |
---|---|
0 | Top-ON, Bottom-OFF |
1 | Bottom-ON, Top-OFF |
The manufacturer defined default value is 0
(Top-ON, Bottom-OFF ).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Ignore start level when recieving dim commands The WT00Z-1 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded in it. A dimmer receiving this command will start dimming from that start level. However, the command can be sent so that the dimmer ignores the start level and instead start dimming from its current level. By default, the WT00Z-1 sends the command so that the dimmer will start dimming from its current dim level rather then the start level embedded in the command. To change this, simply set the configuration parameter to 0.
Parameter No: 5•
Length: 1 Byte
Valid Values = 0 or 1 (default 1 The following option values may be configured -:
Value | Description |
---|---|
0 | Use start level |
1 | Ignore start level |
The manufacturer defined default value is 1
(Ignore start level).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
dim step parameter valid values: 1-99
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
dim timer parameter valid values: 1-255
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
dim step parameter valid values: 1-99
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
dim timer parameter valid values: 1-255
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
dim step parameter valid values: 1-99
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
dim timer parameter valid values: 1-255
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Disable group 4 during a dim command After the WT00Z-1 is commanded to stop dimming when dimming because of the DIM START command, it will then command the Z-Wave devices that are in Group 4 to its new level. To prevent the WT00Z-1 from commanding the Z-Wave devices in Group 4 during this particular occurrence, set Parameter 13 to the value of 1.
Parameter 13
Length: 1 Byte
Valid Values = 0 or 1 (default 0 The following option values may be configured -:
Value | Description |
---|---|
0 | Enable |
1 | Disable |
The manufacturer defined default value is 0
(Enable).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
The switch can control shade control devices if this parameter is set to 1.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
The switch can control shade control devices if this parameter is set to 1.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
The switch can control shade control devices if this parameter is set to 1.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
LED Transmission Indication The WT00Z-1 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the WT00Z-1 is set to flicker for only 1 second.
Parameter 19
Length: 1 Byte
Valid Values = 0 , 1, 2 (default 2) The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Flicker |
1 | Flicker while transmitting |
2 | Flicker for 1 second |
The manufacturer defined default value is 2
(Flicker for 1 second).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Frequency that WT00Z-1 will poll first node in Group 1 The WT00Z-1 will poll the first node in Group 1 in order to keep itself synchronized with the group if this configuration parameter is set to 1. How often it will poll is configured using this parameter.
Parameter 20
Length: 1 Byte
Valid Values = 1 through 255 (default: 2) Values in the range 1 to 255 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Activate/Deactivate polling of first node in Group 1 The WT00Z-1 will poll the first node in Group 1 in order to keep itself synchronized with the group if this configuration parameter is set to 1.
Parameter 21
Length: 1 Byte
Valid Values = 0 , 1 (default 0) The following option values may be configured -:
Value | Description |
---|---|
0 | Do not poll first node in group |
1 | Poll first node in group |
The manufacturer defined default value is 0
(Do not poll first node in group).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The WT00Z-1 supports 4 association groups.
Nodes in this group are turned ON by tapping the top of the paddle or OFF by tapping the bottom of the paddle. Nodes associated into this group are dimmed by pressing and holding the bottom of the paddle until the desired dim level is reached or brightened by pressing and holding the top of the paddle until the desired level is reached. The LED on the WT00Z-1 will indicate the status of this group ONLY.
Association group 1 supports 5 nodes.
Nodes in this group are turned ON by tapping the top of the paddle twice or OFF by tapping the bottom of the paddle twice. Nodes associated into this group are dimmed by tapping the bottom of the paddle once and then pressing and holding the bottom of the paddle until the desired dim level is reached or brightened by tapping the top of the paddle once then pressing and holding the top of the paddle until the desire level is reached
Association group 2 supports 5 nodes.
Nodes in this group are turned ON by tapping the top of the paddle three times or OFF by tapping the bottom of the paddle three times. Nodes associated into this group are dimmed by tapping the bottom of the paddle twice and then pressing and holding the bottom of the paddle until the desired dim level is reached or brightened by tapping the top of the paddle twice then pressing and holding the top of the paddle until the desired level is reached
Association group 3 supports 5 nodes.
Nodes in this group are turned ON or OFF or set to a specific dim level when the WT00Z-1 is controlled remotely. You can place up to 5 nodes in each group. If controlling dimmers, for best results, associate the dimmers into the group first
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |