Skip to content

Files

Latest commit

4e2ca97 · Dec 15, 2018

History

History
314 lines (209 loc) · 10.3 KB

mhs513_0_0.md

File metadata and controls

314 lines (209 loc) · 10.3 KB
layout title
documentation
MH-S513 - ZWave

{% include base.html %}

MH-S513 Touch Panel Switch 3-Way

This describes the Z-Wave device MH-S513, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_mhs513_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

MH-S513 product image

The MH-S513 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Touch Panel Switch is a wall panel built-in with Z-Wave Plus module. With its stylish design and stable performance, the panel can be used to control house-hold electrical appliances like lamp, motor, coffee machine, TV set etc. It supports basic command class,multi channel command class and multi channel association command class, also works as a repeater in a Z-Wave network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.

Inclusion Information

INCLUDING the device into Z-Wave network:

  1. Set controller into INCLUSION mode. Follow instructions provided by controller manufacturer.

  2. Press and hold any key on the panel for 8 seconds or 3 clicks in quick succession.

Note: If inclusion is successful, all INDICATION LEDs on the panel will flash 4 times. 

Exclusion Information

EXCLUDING the device from Z-Wave network:

  1. Set controller into EXCLUSION mode. Follow instructions provided by controller manufacturer.

  2. Press and hold any key on the panel for 8 seconds or 3 clicks in quick succession.

Note: If the exclusion is successful, all INDICATION LEDs on the panel will flash 4 times. The exclusion will delete all association data.

Channels

The following table summarises the channels available for the MH-S513 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number Number
Switch 1 switch_binary1 Switch Switch
Switch 2 switch_binary2 Switch Switch
Switch 3 switch_binary3 Switch Switch

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Switch 3

Switch the power on and off.

The switch_binary3 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the MH-S513. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Switch state saved or not when power failure Switch state saved or not when power failure
3 ALL ON/ALL OFF ALL ON/ALL OFF
4 LED Backlit brightness level LED Backlit brightness level
5 Key Mode Key Mode
6 Key On duration Key On duration
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 2: Switch state saved or not when power failure

Switch state saved or not when power failure 0=not saved,switch will be off when powered again 1=saved,switch will keep the same state when powered again Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: ALL ON/ALL OFF

ALL ON/ALL OFF

0=forbid ALL ON, forbid ALL OFF

  <p>
    1=forbid ALL ON, allow ALL OFF
  </p>
  
  <p>
    2=allow ALL ON, forbid ALL OFF
  </p>
  
  <p>
    255=allow ALL ON, allow ALL OFF
  </p>
</td>
Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: LED Backlit brightness level

LED Backlit brightness level 0 LED disabled 1-10 Min level-Max level >10 same level as 10 Values in the range 0 to 10 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Key Mode

Key Mode 0=single click to switch on/off status

1=Key default as off state. When it is turned on, then it will be turned off automatically after a time period , which can be set in item 5

2=Key default as on state. When it is turned off, then it will be turned on automatically after a time period , which can be set in item 5

3=hold >3s then key is on, and off once released

4=single click to switch on/off status +hold >3s then key is on, and off once released Values in the range 0 to 4 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Key On duration

Key On duration 0x00 infinite

1~65535 unit "sec" Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MH-S513 supports 4 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Associate with gateway Send unsolicited reports to the gateway

Association group 1 supports 1 node.

Group 2: Associate with Key 1

Associate with Key 1 send Basic Set Command to associated devices

Association group 2 supports 5 nodes.

Group 5: Associate with Key 2 if any

Associate with Key 2 if any send Basic Set Command to associated devices

Association group 5 supports 5 nodes.

Group 8: Associate with Key 3 if any

Associate with Key 3 if any send Basic Set Command to associated devices

Association group 8 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.