50x5xx Roller shutter push-button

This describes the Z-Wave device 50x5xx, manufactured by Merten with the thing type UID of merten_50x5xx_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

50x5xx product image

The 50x5xx supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The roller shutter push-button contains a radio receiver for the Merten CONNECT radio system. If you use the blind control inserts 580699 or 580698, you can operate the connected roller shutter drive remotely using a Merten CONNECT radio transmitter. You can also operate the roller shutters using the rocker on the roller shutter push-button.

You can use the Merten CONNECT radio button, the Merten CONNECT radio remote control or the Merten CONNECT radio central unit as the transmitter.

Inclusion Information

Program (transmits Node info frame)

Triple click on operating surface. Used for include/exclude the device by the primary  

Exclusion Information

Reset to the factory settings; exclude  

Triple click on operating surface. Used for include/exclude the device by the primary  

Channels

The following table summarises the channels available for the 50x5xx -:

Channel Channel Id Category Item Type
Blinds Control blinds_control Blinds Rollershutter
Sensor (luminance) sensor_luminance Number
Dimmer 1 switch_dimmer1 DimmableLight Dimmer
Sensor (luminance) 1 sensor_luminance1 Number
Dimmer 2 switch_dimmer2 DimmableLight Dimmer

Blinds Control

Provides start / stop control of blinds.

The blinds_control channel supports the Rollershutter item and is in the Blinds category.

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Dimmer 1

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel supports the Dimmer item and is in the DimmableLight category.

Sensor (luminance) 1

Indicates the current light reading.

The sensor_luminance1 channel supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Dimmer 2

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer2 channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the 50x5xx. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Switching/dimming/shutters
4 Switching single-surface
176 Break (motor protection) Changeover delay (motor protection) Input (0 - 255) * 0.1 s
177 Travel time UP, Byte 1 Input 1 (0 - 255)
178 Travel time UP, Byte 2 Input 2 (0 - 255)
179 Travel time DOWN, Byte 1 Input 1 (0 - 255)
180 Travel time DOWN, Byte 2 Input 2 (0 - 255)

Parameter 0: Switching/dimming/shutters

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 4: Switching single-surface

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 176: Break (motor protection)

Changeover delay (motor protection) Input (0 - 255) * 0.1 s

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_176_1 and is of type INTEGER.

Parameter 177: Travel time UP, Byte 1

Input 1 (0 - 255) Raising time
(256 * Input 1 + input 2) * 0.1 s   Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_177_1 and is of type INTEGER.

Parameter 178: Travel time UP, Byte 2

Input 2 (0 - 255) Raising time
(256 * Input 1 + input 2) * 0.1 s   Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_178_1 and is of type INTEGER.

Parameter 179: Travel time DOWN, Byte 1

Input 1 (0 - 255) Lowering time
(256 * Input 1 + input 2) * 0.1 s   Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_179_1 and is of type INTEGER.

Parameter 180: Travel time DOWN, Byte 2

Input 2 (0 - 255) Lowering time
(256 * Input 1 + input 2) * 0.1 s   Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_180_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 50x5xx supports 1 association group.

Group 1: Other device to be switched

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1 Linked to BASIC
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_SENSOR_CONFIGURATION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1 Linked to BASIC
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_SENSOR_CONFIGURATION_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1 Linked to BASIC
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.