This describes the Z-Wave device ASP-3-1, manufactured by ID-RF with the thing type UID of nodon_asp31_00_000
.
The ASP-3-1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Press on the Smart Plug button during 2 seconds until the LED becomes red. Release the button, the LED will then glow in red. The Smart Plug is in “Learning mode”. To add or to remove the Smart Plug from a Z-Wave® network, follow “INCLUSION” or “EXCLUSION” procedures below.
If the Smart Plug is not added or removed from a network within 30 seconds (or if the button is pushed during learning mode), the Smart Plug will automatically exit learning mode.
To perform a factory reset, press on the Smart Plug button during 5 seconds until the LED becomes orange. Release the button, the LED will blink red/green. Factory Reset clears the Smart Plug’s memory and set parameters to default value.
Please use this procedure only when the primary controller is missing or otherwise inoperable. Resetting the Smart Plug does not mean it has been removed from Z-Wave network controller’s memory. Use the primary controller to remove the Smart Plug from its Z-Wave network (follow “EXCLUSION” procedures below), before doing a Factory Reset.
To add the Smart Plug into a Z-Wave network:
- Plug the Smart Plug.
- Put the Smart Plug in “Learning mode”.
- Within 30 seconds put the Z-Wave Controller in “Learning mode” (See the Controller user guide for its own Inclusion procedure).
- The Smart Plug will confirm the Inclusion procedure by blinking its LED in Green.
To remove the Smart Plug from a Z-Wave network:
- Make sure the Smart Plug is plugged.
- Put the Smart Plug in “Learning mode”.
- Within 30 seconds put the Z-Wave Controller in “Learning mode” (See the Controller user guide for its own Exclusion procedure).
- The Smart Plug will confirm the Exclusion procedure by blinking its LED in Red.
The following table summarises the channels available for the ASP-3-1 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Alarm (system) | alarm_system | Switch | |
Alarm (power) | alarm_power | Door | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
DELETE ME (alarm_system seems to be unsupported)
Indicates if a system alarm is triggered.
The alarm_system
channel supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a power alarm is triggered.
The alarm_power
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 4 configuration parameters available in the ASP-3-1. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Default State | |
2 | Power Failure | |
3 | Follow State | |
4 | Always On | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Status of the Smart Plug after a Power Failure or after being plugged The following option values may be configured, in addition to values in the range 0 to 63 -:
Value | Description |
---|---|
0 | Off |
1 | On |
2 | Status before Power Failure |
The manufacturer defined default value is 2
(Status before Power Failure).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
This parameter is to set-up the Power Failure / Recover notification and the associated group (Groups 4, 5, 6, 7, 8).
The value may be a sum of available values. For example, if you want to activate Power Failure and enable group 4 & 5, the parameter value should be 1+2+4=7. The following option values may be configured, in addition to values in the range 0 to 63 -:
Value | Description |
---|---|
0 | Power Failure detection disable |
1 | Power Failure enable (report to Lifeline only) |
2 | Enable group 4 |
4 | Enable group 5 |
8 | Enable group 6 |
16 | Enable group 7 |
32 | Enable group 8 |
The manufacturer defined default value is 0
(Power Failure detection disable).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable group 2 & 3 |
1 | Enable group 2 |
2 | Enable group 3 |
3 | Enable group 2 & 3 |
The manufacturer defined default value is 3
(Enable group 2 & 3).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Always ON disabled |
1 | Always ON enabled |
The manufacturer defined default value is 0
(Always ON disabled).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ASP-3-1 supports 8 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. This group is generally used to report information of the Smart Plug to the Main Controller of the network.
Association group 1 supports 5 nodes.
When the Smart Plug is switched ON (respectively OFF) using the local button, it will send ON (respectively OFF) command to the associated devices. No command is sent if the Smart Plug is switched ON or OFF wirelessly.
Association group 2 supports 5 nodes.
When the Smart Plug is switched ON (respectively OFF) using the local button, it will send OFF (respectively ON) command to the associated devices. No command is sent if the Smart Plug is switched ON or OFF wirelessly.
Association group 3 supports 5 nodes.
When the Smart Plug detects a power failure or recovers from a power failure, it sends the notification report to the associated devices.
The notification sent is “Notification Report: Power Management – AC Disconnected / Re-connected”.
Association group 4 supports 5 nodes.
When the Smart Plug detects a Power Failure, it will switch ON the associated devices.
Association group 5 supports 5 nodes.
When the Smart Plug detects a Power Failure, it will switch OFF the associated devices.
Association group 6 supports 5 nodes.
When the Smart Plug detects a Power Recover, it will switch ON the associated devices.
Association group 7 supports 5 nodes.
When the Smart Plug detects a Power Recover, it will switch OFF the associated devices.
Association group 8 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.