FT132 Dual Nano Switch with Energy Metering

This describes the Z-Wave device FT132, manufactured by Fantem with the thing type UID of oomi_ft132_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

FT132 product image

The FT132 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Fantech Dual Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. 
In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. 
It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch. 
The Dual Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.

Inclusion Information

If you want your In-Wall Smart Switch (Dual) as a non-secure device in your Z-Wave network,press the Action Button once on In-Wall Smart Switch (Dual) when you pair it to your gateway. Ifinclusion is successful, the green LED will be on for 2 seconds, and then return to a solidindication. If inclusion is unsuccessful, the red LED will be on for 2 seconds and then return to acolourful gradient.

Exclusion Information

If at some stage, your primary controller is missing or inoperable, you may wish to reset all ofyour In-Wall Smart Switch (Dual)’s settings to their factory defaults. To do this, press and holdthe Action Button for 20 seconds and then release it. Your In-Wall Smart Switch (Dual) will nowbe reset to its original settings, and the green LED will be solid for 2 seconds and then remain thecolourful gradient status as a confirmation.

Channels

The following table summarises the channels available for the FT132 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Scene Number scene_number Number
Electric meter (watts) meter_watts Energy Number
Electric meter (volts) meter_voltage Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (amps) meter_current Energy Number
Alarm (power) alarm_power Energy Switch
Alarm (heat) alarm_heat Fire Switch
Clock Time Offset time_offset Temperature Number
Switch 1 switch_binary1 Switch Switch
Electric meter (watts) 1 meter_watts1 Energy Number
Electric meter (volts) 1 meter_voltage1 Energy Number
Electric meter (kWh) 1 meter_kwh1 Energy Number
Electric meter (amps) 1 meter_current1 Energy Number
Switch 2 switch_binary2 Switch Switch
Electric meter (watts) 2 meter_watts2 Energy Number
Electric meter (volts) 2 meter_voltage2 Energy Number
Electric meter (kWh) 2 meter_kwh2 Energy Number
Electric meter (amps) 2 meter_current2 Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (heat)

Indicates if a heat alarm is triggered.

The alarm_heat channel supports the Switch item and is in the Fire category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel supports the Number item and is in the Temperature category.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 1

Indicates the instantaneous voltage.

The meter_voltage1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 1

Indicates the instantaneous current consumption.

The meter_current1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 2

Indicates the instantaneous voltage.

The meter_voltage2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 2

Indicates the instantaneous current consumption.

The meter_current2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 22 configuration parameters available in the FT132. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Current Overload Protection. Current Overload Protection.
4 Overheat protection Overheat protection
20 Configure the output status after re-power on it. Configure the output status after re-power on it.
80 Group 1 notifications To set which notification would be sent to the associated devices (Group 1)
81 Group 3 notifications To set which notification would be sent to association group 3
82 Group 4 notifications To set which notification would be sent to association group 4
90 Enables/disables parameter 91 and 92 below: Enables/disables parameter 91 and 92 below:
91 Set the threshold value of wattage. Set the threshold value of wattage.
92 Set the threshold value of wattage. Set the threshold value of wattage.
100 Set parameter 101-103 to default value Reset the parameter 101-103
101 Set group 1 reports To set which reports need to be sent in Report group 1
102 To set which reports need to be sent in Report group 2. To set which reports need to be sent in Report group 2.
103 To set which reports need to be sent in Report group 3 To set which reports need to be sent in Report group 3.
110 Set parameter 111-113 to default value. Set parameter 111-113 to default value.
111 Set the interval of automatic report for Report group 1. Set the interval of automatic report for Report group 1.
112 Set the interval of automatic report for Report group 2 Set the interval of automatic report for Report group 2.
113 Set the interval of automatic report for Report group 2. Set the interval of automatic report for Report group 2.
120 Configure the external switch mode for S1 Configure the external switch mode for S1
121 Configure the external switch mode for S2. Configure the external switch mode for S2.
122 Set the control destination for external switch Set the control destination for external switch
252 Lock/unlock configuration parameters Lock/unlock configuration parameters
255 Reset the Dual Nano Switch Reset the Dual Nano Switch
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Current Overload Protection.

Current Overload Protection.

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 1 (Enable).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Overheat protection

Overheat protection

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 20: Configure the output status after re-power on it.

Configure the output status after re-power on it.

The following option values may be configured -:

Value Description
0 Last status
1 Always on
2 Always off

The manufacturer defined default value is 0 (Last status).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 80: Group 1 notifications

To set which notification would be sent to the associated devices (Group 1)

The following option values may be configured -:

Value Description
0 Send Nothing
1 Send Hail CC
2 Send Basic CC report
3 Send Hail CC when using the manual switch

The manufacturer defined default value is 0 (Send Nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 81: Group 3 notifications

To set which notification would be sent to association group 3

The following option values may be configured -:

Value Description
0 Send Nothing
1 Send Basic Set CC

The manufacturer defined default value is 1 (Send Basic Set CC).

This parameter has the configuration ID config_81_1 and is of type INTEGER.

Parameter 82: Group 4 notifications

To set which notification would be sent to association group 4

The following option values may be configured -:

Value Description
0 Send Nothing
1 Send Basic Set CC

The manufacturer defined default value is 1 (Send Basic Set CC).

This parameter has the configuration ID config_82_1 and is of type INTEGER.

Parameter 90: Enables/disables parameter 91 and 92 below:

Enables/disables parameter 91 and 92 below:

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Set the threshold value of wattage.

Set the threshold value of wattage.

Values in the range 0 to 60000 may be set.

The manufacturer defined default value is 25.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Set the threshold value of wattage.

Set the threshold value of wattage.

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 100: Set parameter 101-103 to default value

Reset the parameter 101-103

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_100_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 101: Set group 1 reports

To set which reports need to be sent in Report group 1

The following option values may be configured -:

Value Description
1 Send Meter Report of energy (kWh)
2 Send Meter Report of wattage (W)
4 Send Meter Report of voltage (V)
8 Send Meter Report of current (A)
256 Send Multi Channel Meter Report of wattage (W) on Channel 1
512 Send Multi Channel Meter Report of wattage (W) on Channel 2
2048 Send Multi Channel Meter Report of energy (kWh) on Channel 1
4096 Send Multi Channel Meter Report of energy (kWh) on Channel 2
65536 Send Multi Channel Meter Report of voltage (V) on Channel 1
131072 Send Multi Channel Meter Report of voltage (V) on Channel 2
524288 Send Multi Channel Meter Report of current (A) on Channel 1
1048576 Send Multi Channel Meter Report of current (A) on Channel 2

The manufacturer defined default value is 0.

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: To set which reports need to be sent in Report group 2.

To set which reports need to be sent in Report group 2.

The following option values may be configured -:

Value Description
1 Send Meter Report of energy (kWh)
2 Send Meter Report of wattage (W)
4 Send Meter Report of voltage (V)
8 Send Meter Report of current (A)
256 Send Multi Channel Meter Report of wattage (W) on Channel 1
512 Send Multi Channel Meter Report of wattage (W) on Channel 2
2048 Send Multi Channel Meter Report of energy (kWh) on Channel 1
4096 Send Multi Channel Meter Report of energy (kWh) on Channel 2
65536 Send Multi Channel Meter Report of voltage (V) on Channel 1
131072 Send Multi Channel Meter Report of voltage (V) on Channel 2
524288 Send Multi Channel Meter Report of current (A) on Channel 1
1048576 Send Multi Channel Meter Report of current (A) on Channel 2

The manufacturer defined default value is 0.

This parameter has the configuration ID config_102_1 and is of type INTEGER.

Parameter 103: To set which reports need to be sent in Report group 3

To set which reports need to be sent in Report group 3.

The following option values may be configured -:

Value Description
1 Send Meter Report of voltage (V)
2 Send Meter Report of current (A)
4 Send Meter Report of wattage (W)
8 Send Meter Report of energy (kWh)
256 Send Multi Channel Meter Report of wattage (W) on Channel 1
512 Send Multi Channel Meter Report of wattage (W) on Channel 2
2048 Send Multi Channel Meter Report of energy (kWh) on Channel 1
4096 Send Multi Channel Meter Report of energy (kWh) on Channel 2
65536 Send Multi Channel Meter Report of voltage (V) on Channel 1
131072 Send Multi Channel Meter Report of voltage (V) on Channel 2
524288 Send Multi Channel Meter Report of current (A) on Channel 1
1048576 Send Multi Channel Meter Report of current (A) on Channel 2

The manufacturer defined default value is 0.

This parameter has the configuration ID config_103_1 and is of type INTEGER.

Parameter 110: Set parameter 111-113 to default value.

Set parameter 111-113 to default value.

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_110_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 111: Set the interval of automatic report for Report group 1.

Set the interval of automatic report for Report group 1.

Values in the range 1 to 2147483647 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Set the interval of automatic report for Report group 2

Set the interval of automatic report for Report group 2.

Values in the range 1 to 2147483647 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Set the interval of automatic report for Report group 2.

Set the interval of automatic report for Report group 2.

Values in the range 1 to 2147483647 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Parameter 120: Configure the external switch mode for S1

Configure the external switch mode for S1

The following option values may be configured -:

Value Description
0 Enter automatic identification mode
1 2-state switch mode
2 3 way switch mode
3 Momentary push button mode

The manufacturer defined default value is 0 (Enter automatic identification mode).

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Parameter 121: Configure the external switch mode for S2.

Configure the external switch mode for S2.

The following option values may be configured -:

Value Description
0 Enter automatic identification mode
1 2-state switch mode
2 3 way switch mode
3 Momentary push button mode

The manufacturer defined default value is 0 (Enter automatic identification mode).

This parameter has the configuration ID config_121_1 and is of type INTEGER.

Parameter 122: Set the control destination for external switch

Set the control destination for external switch

The following option values may be configured -:

Value Description
1 control the output loads of itself.
2 control the other nodes
3 control the output loads of itself and other nodes.

The manufacturer defined default value is 3 (control the output loads of itself and other nodes.).

This parameter has the configuration ID config_122_1 and is of type INTEGER.

Parameter 252: Lock/unlock configuration parameters

Lock/unlock configuration parameters

The following option values may be configured -:

Value Description
0 Unlock
1 Lock

The manufacturer defined default value is 0 (Unlock).

This parameter has the configuration ID config_252_1 and is of type INTEGER.

Parameter 255: Reset the Dual Nano Switch

Reset the Dual Nano Switch

The following option values may be configured -:

Value Description
0 (Default) Reset all configuration parameters

The manufacturer defined default value is 0 ((Default) Reset all configuration parameters).

This parameter has the configuration ID config_255_4 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The FT132 supports 4 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. When the load state of Dual Nano Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group.

Association group 1 supports 5 nodes.

Group 2: Forward the Basic Set

Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. (E.g. Send/forward Basic Set to control the other nodes in association Group

Association group 2 supports 5 nodes.

Group 3: Send Basic Set

(configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated. Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 0x78 should be

Association group 3 supports 5 nodes.

Group 4: Send Basic Set

Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated. Note: The Switch Mode of external switch S2 should be identified successfully, which means that the value of Configuration parameter

Association group 4 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.