PSC234ZW Metering Plug switching 16A

This describes the Z-Wave device *PSC234ZW *, manufactured by permundo GmbH with the thing type UID of permundo_psc234zw_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

PSC234ZW  product image

The PSC234ZW supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the PSC234ZW -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the PSC234ZW . Detailed information on each parameter can be found in the sections below.

Param Name Description
31 LocalControlOff Disable local control of plug

Parameter 31: LocalControlOff

Disable local control of plug 31d Size:1 Default: 00d

Bit 0:

        1=LocalControlOff

        0=LocalControlOn

Bit 1-7: 0 (siehe auch CC_PROTECTION) 

LocalControlOff: In der Werkseinstellung (LocalControlOff=0) ändert das Gerät den Zustand des Ausgangs bei Betätigung des TouchButtons. Durch das Setzen von LocalControlOff=1 kann der Ausgang des Geräts nur noch über Z-Wave+ gesteuert werden.

LocalControlOff wird entweder über Parameter 31 der CC_CONFIGURATION oder über CC_PROTECTION, PROTECTION_SET konfiguriert.  The following option values may be configured -:

Value Description
1 Disable Local Control

The manufacturer defined default value is 0.

This parameter has the configuration ID config_31_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PSC234ZW supports 1 association group.

Group 1: Reports

Reports triggered by change of relay state, meter values or time Assoziationsgruppe Gruppe 1 (lifeline): 5 Events/Notifications:

(1) Sendet COMMAND_CLASS_BASIC, BASIC_REPORT und COMMAND_CLASS_SWITCH_BINARY, BINARY_REPORT jeweils nach Änderung des RelaisStatus.

(2) Sendet COMMAND_CLASS_METER_V2, METER_REPORT_V2 jeweils nach Änderung der Messwerte Energie oder Leistung entweder um einen Minimalbetrag, oder nach Ablauf einer Maximalzeit. Ebenso wird nach jedem Report eine Mindestzeit gewartet, bevor ein nächster Report gesendet wird. Zeiten für Werte Energie/Leistung:

Mindestzeit zwischen 2 Reports: 1s PSC234ZW RC2.05 G3 DE 7

Maximalzeit bis zum nächsten Report: 15min. Trigger bei Abweichung seit letzter Messung: 4% Leistung (mind. 2W) oder 1Wh Energie 

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_CONFIGURATION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2