PAN04 - ZWave

{% include base.html %}

PAN04 In Wall Dual Relay(1 Way) Switch Module 2x 1.5kW with power meter

This describes the Z-Wave device PAN04, manufactured by Philio Technology Corp with the thing type UID of philio_pan04_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

PAN04 product image

The PAN04 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This in-wall dual relay switch module is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration.

There are many kind of application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. 

This in-wall switch module is able to detect Instant power wattage (51500W) and overload wattage (16001700W) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.

Inclusion Information

Adding to Z-WaveTM Network

In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices.

Auto Inclusion

The function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power.

Note: Auto inclusion timeout is 4 minute during which the node information of explorer frame will be emitted once every 5 seconds. Unlike "inclusion" function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.

The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices.

  • No node ID
    • The Z-Wave Controller does not allocate a node ID to the Switch
    • LED Indication: 2-second on, 2-second off
  • Inclusion
    • Description
      1. Have Z-Wave Controller entered inclusion mode.
      2. Pressing INCLUDE_BUTTON three times within 1.5 seconds will enter inclusion mode
    • LED Indication: One press one flash

Exclusion Information

The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices.

  • Exclusion
    • Description
      1. Have Z-Wave Controller entered exclusion mode.
      2. Pressing INCLUDE_BUTTON three times within 1.5 seconds will enter exclusion mode.
    • LED Indication: One press one flash
  • Node ID has been excluded
    • 2-second on, 2-second off

Channels

The following table summarises the channels available for the PAN04 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Alarm alarm_general alarm_general Alarm Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (power factor) 1 meter_powerfactor1 meter_powerfactor Energy Number
Electric meter (amps) 1 meter_current1 meter_current Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (power factor) 2 meter_powerfactor2 meter_powerfactor Energy Number
Electric meter (amps) 2 meter_current2 meter_current Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (volts) 2 meter_voltage2 meter_voltage Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Switch 3 switch_binary3 switch_binary Switch Switch
Electric meter (power factor) 3 meter_powerfactor3 meter_powerfactor Energy Number
Electric meter (amps) 3 meter_current3 meter_current Energy Number
Electric meter (kWh) 3 meter_kwh3 meter_kwh Energy Number
Electric meter (volts) 3 meter_voltage3 meter_voltage Energy Number
Electric meter (watts) 3 meter_watts3 meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor) 1

Indicates the instantaneous power factor.

The meter_powerfactor1 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 1

Indicates the instantaneous current consumption.

The meter_current1 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 1

Indicates the instantaneous voltage.

The meter_voltage1 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor) 2

Indicates the instantaneous power factor.

The meter_powerfactor2 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 2

Indicates the instantaneous current consumption.

The meter_current2 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 2

Indicates the instantaneous voltage.

The meter_voltage2 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 3

Switch the power on and off.

The switch_binary3 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor) 3

Indicates the instantaneous power factor.

The meter_powerfactor3 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 3

Indicates the instantaneous current consumption.

The meter_current3 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 3

Indicates the energy consumption (kWh).

The meter_kwh3 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 3

Indicates the instantaneous voltage.

The meter_voltage3 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 3

Indicates the instantaneous power consumption.

The meter_watts3 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the PAN04. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 W meter report period Period for reporting W meter
2 kWh meter report period Period for reporting kWh meter
3 Selected endpoint Which endpoint is addressed by the BASIC command class
4 Switch mode Change the external switch mode
5 Threshold of Watt for Load Caution If threshold of wattage is reached, a meter report will be generated
6 Threshold of kWh for Load Caution If threshold of kWh is reached, a Meter Report will be generated
7 Restore switch state mode Restore switch state mode
8 Auto Off Timer Auto Off Timer
9 RF off command mode RF off command mode
10 Endpoint 3 Endpoint 3
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: W meter report period

Period for reporting W meter If the setting is configured for 1 hour (value = 720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 seconds Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: kWh meter report period

Period for reporting kWh meter If the setting is configured for 1 hour (value = 6), the device will report its total power consumption every 1 hour to Z-Wave Controller. 

Unit: 10 minutes Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Selected endpoint

Which endpoint is addressed by the BASIC command class If the Controller is not using Multi_Channel command class to access the endpoint of PAN04, you may configure the endpoint value to react the Basic Command Class The following option values may be configured -:

Value Description
1 Relay 1
2 Relay 2
3 Relay 1 + 2

The manufacturer defined default value is 1 (Relay 1).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Switch mode

Change the external switch mode

The following option values may be configured -:

Value Description
1 Edge mode
2 Pulse mode
3 Edge-Toggle mode

The manufacturer defined default value is 1 (Edge mode).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Threshold of Watt for Load Caution

If threshold of wattage is reached, a meter report will be generated

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 750.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Threshold of kWh for Load Caution

If threshold of kWh is reached, a Meter Report will be generated

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Restore switch state mode

Restore switch state mode Restores the switch state setting in case the device was disconnected from the power source. The following option values may be configured -:

Value Description
0 Switch Off
1 Last State
2 Switch On

The manufacturer defined default value is 1 (Last State).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Auto Off Timer

Auto Off Timer Whenever the device switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: RF off command mode

RF off command mode Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands. The following option values may be configured -:

Value Description
0 Switch Off
1 Ignore
2 Switch Toggle
3 Switch On

The manufacturer defined default value is 1 (Ignore).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Endpoint 3

Endpoint 3 Multi-Channel Command is a good way to control relay1 and relay2 of PAN04 individually. The endpoint3 of PAN04 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. The following option values may be configured -:

Value Description
1 Exists
2 Doesn't Exist

The manufacturer defined default value is 1 (Exists).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN04 supports 3 association groups.

Group 1: Relay 1 + 2

Association group 1 supports 1 node.

Group 2: Relay 1

Association group 2 supports 1 node.

Group 3: Relay 2

Association group 3 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.