layout | title |
---|---|
documentation |
PAN04 - ZWave |
{% include base.html %}
This describes the Z-Wave device PAN04, manufactured by Philio Technology Corp with the thing type UID of philio_pan04_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The PAN04 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This in-wall dual relay switch module is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration.
There are many kind of application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light.
This in-wall switch module is able to detect Instant power wattage (51500W) and overload wattage (16001700W) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 4 minute during which the node information of explorer frame will be emitted once every 5 seconds. Unlike "inclusion" function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices.
- No node ID
- The Z-Wave Controller does not allocate a node ID to the Switch
- LED Indication: 2-second on, 2-second off
- Inclusion
- Description
- Have Z-Wave Controller entered inclusion mode.
- Pressing INCLUDE_BUTTON three times within 1.5 seconds will enter inclusion mode
- LED Indication: One press one flash
- Description
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices.
- Exclusion
- Description
- Have Z-Wave Controller entered exclusion mode.
- Pressing INCLUDE_BUTTON three times within 1.5 seconds will enter exclusion mode.
- LED Indication: One press one flash
- Description
- Node ID has been excluded
- 2-second on, 2-second off
The following table summarises the channels available for the PAN04 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Electric meter (power factor) 1 | meter_powerfactor1 | meter_powerfactor | Energy | Number |
Electric meter (amps) 1 | meter_current1 | meter_current | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
Electric meter (volts) 1 | meter_voltage1 | meter_voltage | Energy | Number |
Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Electric meter (power factor) 2 | meter_powerfactor2 | meter_powerfactor | Energy | Number |
Electric meter (amps) 2 | meter_current2 | meter_current | Energy | Number |
Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
Electric meter (volts) 2 | meter_voltage2 | meter_voltage | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
Switch 3 | switch_binary3 | switch_binary | Switch | Switch |
Electric meter (power factor) 3 | meter_powerfactor3 | meter_powerfactor | Energy | Number |
Electric meter (amps) 3 | meter_current3 | meter_current | Energy | Number |
Electric meter (kWh) 3 | meter_kwh3 | meter_kwh | Energy | Number |
Electric meter (volts) 3 | meter_voltage3 | meter_voltage | Energy | Number |
Electric meter (watts) 3 | meter_watts3 | meter_watts | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power factor.
The meter_powerfactor1
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current1
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh1
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage1
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts1
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power factor.
The meter_powerfactor2
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current2
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh2
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage2
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts2
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary3
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power factor.
The meter_powerfactor3
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current3
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh3
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage3
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts3
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 10 configuration parameters available in the PAN04. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | W meter report period | Period for reporting W meter |
2 | kWh meter report period | Period for reporting kWh meter |
3 | Selected endpoint | Which endpoint is addressed by the BASIC command class |
4 | Switch mode | Change the external switch mode |
5 | Threshold of Watt for Load Caution | If threshold of wattage is reached, a meter report will be generated |
6 | Threshold of kWh for Load Caution | If threshold of kWh is reached, a Meter Report will be generated |
7 | Restore switch state mode | Restore switch state mode |
8 | Auto Off Timer | Auto Off Timer |
9 | RF off command mode | RF off command mode |
10 | Endpoint 3 | Endpoint 3 |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Period for reporting W meter If the setting is configured for 1 hour (value = 720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 seconds Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
Period for reporting kWh meter If the setting is configured for 1 hour (value = 6), the device will report its total power consumption every 1 hour to Z-Wave Controller.
Unit: 10 minutes Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Which endpoint is addressed by the BASIC command class If the Controller is not using Multi_Channel command class to access the endpoint of PAN04, you may configure the endpoint value to react the Basic Command Class The following option values may be configured -:
Value | Description |
---|---|
1 | Relay 1 |
2 | Relay 2 |
3 | Relay 1 + 2 |
The manufacturer defined default value is 1
(Relay 1).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Change the external switch mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Edge mode |
2 | Pulse mode |
3 | Edge-Toggle mode |
The manufacturer defined default value is 1
(Edge mode).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
If threshold of wattage is reached, a meter report will be generated
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 750
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
If threshold of kWh is reached, a Meter Report will be generated
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 10000
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
Restore switch state mode Restores the switch state setting in case the device was disconnected from the power source. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch Off |
1 | Last State |
2 | Switch On |
The manufacturer defined default value is 1
(Last State).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Auto Off Timer Whenever the device switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
RF off command mode Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch Off |
1 | Ignore |
2 | Switch Toggle |
3 | Switch On |
The manufacturer defined default value is 1
(Ignore).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Endpoint 3 Multi-Channel Command is a good way to control relay1 and relay2 of PAN04 individually. The endpoint3 of PAN04 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. The following option values may be configured -:
Value | Description |
---|---|
1 | Exists |
2 | Doesn't Exist |
The manufacturer defined default value is 1
(Exists).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PAN04 supports 3 association groups.
Association group 1 supports 1 node.
Association group 2 supports 1 node.
Association group 3 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V3 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.