layout | title |
---|---|
documentation |
005206 - ZWave |
{% include base.html %}
This describes the Z-Wave device 005206, manufactured by Popp & Co with the thing type UID of popp_005206_00_000
.
The 005206 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The 005206 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The 005206 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The following table summarises the channels available for the 005206 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Door | Switch |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Sensor (relative humidity) | sensor_relhumidity | Humidity | Number |
Sensor (barometric pressure) | sensor_barpressure | Number | |
Sensor (velocity) | sensor_velocity | Number | |
Sensor (dew point) | sensor_dewpoint | Temperature | Number |
Sensor (luminance) | sensor_luminance | Number | |
Electric meter (pulses) | meter_pulse | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Battery Level | battery-level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the barometric pressure.
The sensor_barpressure
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates the current velocity.
The sensor_velocity
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates the dewpoint.
The sensor_dewpoint
channel supports the Number
item and is in the Temperature
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current light reading.
The sensor_luminance
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates the pulse count.
The meter_pulse
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 2 configuration parameters available in the 005206. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Wind Speed Action Threshold | Available Parameters: 0 - Off 1 - 30 in milliseconds Default = 6 m/s |
2 | Twilight Action Threshold | Set from 0 - 100 % Default = 37% (street lighting) |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Available Parameters: 0 - Off 1 - 30 in milliseconds Default = 6 m/s
Values in the range 0 to 30 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Set from 0 - 100 % Default = 37% (street lighting)
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 37
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 005206 supports 4 association groups.
Association group 1 supports 1 node.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V6 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_LANGUAGE_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CMD_V1 | |
COMMAND_CLASS_ASSOCIATION_COMMAND_CONFIGURATION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.