layout title
documentation
ED2.0 - ZWave

{% include base.html %}

ED2.0 Eneco Meter Adapter

This describes the Z-Wave device ED2.0, manufactured by Prodrive Technologies with the thing type UID of prodrive_ed20_00_000.

The ED2.0 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The meter adapter measures gas and electricity usage of analog and digital meters. Analog meters are read by means of optical sensors that can be placed on the meter to monitor the rotating disc or the blinking LED. In case of a digital meter, the meter adapter can be connected to the digital meter by means of a P1 digital communication interface. The meter adapter measures the cumulative and instantaneous gas and electricity consumption and sends this information to a Z-Wave enabled display (ED2.0 Display).

Inclusion Information

Press Button

Channels

The following table summarises the channels available for the ED2.0 -:

Channel Channel Id Category Item Type
Clock Time Offset time_offset Temperature Number
Gas meter (cubic meters) meter_gas_cubic_meters1 Energy Number
Electric meter (kWh) meter_kwh2 Energy Number
Electric meter (kWh) meter_kwh3 Energy Number
Electric meter (kWh) meter_kwh4 Energy Number
Electric meter (kWh) meter_kwh5 Energy Number
Electric meter (kWh) meter_kwh6 Energy Number

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel supports the Number item and is in the Temperature category.

Gas meter (cubic meters)

Indicates the gas use in cubic meters.

The meter_gas_cubic_meters1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Single-E import

Indicates the energy consumption (kWh).

The meter_kwh2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Twin-E day import

Indicates the energy consumption (kWh).

The meter_kwh3 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

<td>
   
</td>
Twin-E day export

Indicates the energy consumption (kWh).

The meter_kwh4 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

<td>
   
</td>
Twin-E night import

Indicates the energy consumption (kWh).

The meter_kwh5 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

<td>
   
</td>
Twin-E night export

Indicates the energy consumption (kWh).

The meter_kwh6 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the ED2.0. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Gas Metering Enable and disable gas metering
1 Gas Meter resolution The resolution of the analog gas meter
2 Electricity metering Enable and disable Electricity metering
3 Electricity meter resolution The resolution of the analog electricity meter

Parameter 0: Gas Metering

Enable and disable gas metering

The following option values may be configured -:

Value Description
0 disable gas metering
1 enable gas metering

The manufacturer defined default value is 1 (enable gas metering).

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 1: Gas Meter resolution

The resolution of the analog gas meter The resolution of the analog gas meter (revolutions per m³) in unsigned Q14.2 notation. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 400.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: Electricity metering

Enable and disable Electricity metering

The following option values may be configured -:

Value Description
0 disable electricity metering
1 enable electricity metering

The manufacturer defined default value is 1 (enable electricity metering).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Electricity meter resolution

The resolution of the analog electricity meter The resolution of the analog electricity meter (revolutions per kWh) in unsigned Q14.2 notation. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 400.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_METER_TBL_CONFIG_V1
COMMAND_CLASS_METER_TBL_MONITOR_V1
COMMAND_CLASS_METER_TBL_PUSH_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_TIME_PARAMETERS_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_METER_TBL_MONITOR_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_METER_TBL_MONITOR_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_METER_TBL_MONITOR_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1

Endpoint 4

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_METER_TBL_MONITOR_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1

Endpoint 5

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_METER_TBL_MONITOR_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1

Endpoint 6

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_METER_TBL_MONITOR_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.