Smart Plug 16A Smart Plug

This describes the Z-Wave device Smart Plug 16A, manufactured by Goap with the thing type UID of qubino_smartplug_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

Smart Plug 16A product image

The Smart Plug 16A supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This Z-Wave module is used for switching and energy measurements in single-phase electrical power networks and can be used in residential, industrial and utility applications.

Power supply: 230V +/- 10%, 50 Hz

Power load: 15A resistive max.

Overload protection >16 A

Power consumption <1W

Inclusion Information

Auto inclusion (first time usage)

  • start inclusion mode of z-wave controller
  • plug device into power outlet (5 seconds auto inclusion)

Manual inclusion

  • plug device into power outlet
  • start inclusion mode of z-wave controller
  • press the service button (S) 3 times within 3 seconds

Exclusion Information

  • plug device into power outlet
  • ensure device is within maximum 1 meter (3 feet) of the main controller
  • enable exclusion mode on main controller
  • press service button (S) on module 3 times within 3 seconds (please note: configuration parameters will not be reset!)

Channels

The following table summarises the channels available for the Smart Plug 16A -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (volts) meter_voltage Energy Number
Electric meter (amps) meter_current Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number
Alarm (power) alarm_power Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the Smart Plug 16A. Detailed information on each parameter can be found in the sections below.

Param Name Description
10 Activate / deactivate functions ALL ON / ALL OFF
11 Automatic turning OFF relay after set time When the relay is turned ON, it automatically turns OFF after the defined time
12 On automatically with timer Turn Smart plug On Automatically with Timer
15 Timer Settings Unit Set Timer Units to Seconds or Milliseconds
30 Restore state ofter power failure Restore on/off status for Smart plug 16A after power failure
40 Treshold Change in Power for reporting Change of power consumption [Watt] reporting threshold
41 Treshold time for power reporting Treshold time for power reporting [Watt]
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 10: Activate / deactivate functions ALL ON / ALL OFF

The following option values may be configured -:

Value Description
0 ALL ON disabled, ALL of disabled
1 ALL ON disabled, AL OFF active
2 ALL ON active, ALL OFF disabled
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Automatic turning OFF relay after set time

When the relay is turned ON, it automatically turns OFF after the defined time The timer is reset each time, the module receives an ON command (from push button/main controller/association).

  • 0 = Auto OFF disabled
  • 1 - 32535 = 1 second to 32535 seconds delay. Auto OFF is enabled with defined time. Step is 1s. The following option values may be configured, in addition to values in the range 0 to 32535 -:
Value Description
0 Auto OFF disabled

The manufacturer defined default value is 0 (Auto OFF disabled).

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: On automatically with timer

Turn Smart plug On Automatically with Timer If Smart plug 16A is OFF, you can schedule it to turn ON automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an OFF command, either remotely (from the gateway (hub) or associated device) or locally from the switch.

  • 0 - Auto ON Disabled
  • 1 - 32535 = 1 - 32535 seconds (or milliseconds – see Parameter no. 15) Auto ON timer enabled- for a given amount of seconds (or milliseconds). The following option values may be configured -:
Value Description
0 Auto ON Disabled
0 please delete this option

The manufacturer defined default value is 0 (please delete this option).

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 15: Timer Settings Unit

Set Timer Units to Seconds or Milliseconds Choose if you want to set the timer in seconds or milliseconds in parameters 11 and 12. Please note that the value for this parameter applies to settings for Smart plug 16A in all of the above parameters (timer on / timer off). The following option values may be configured -:

Value Description
0 timer set in seconds
1 timer set in milliseconds

The manufacturer defined default value is 0 (timer set in seconds).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 30: Restore state ofter power failure

Restore on/off status for Smart plug 16A after power failure

The following option values may be configured -:

Value Description
0 Restore state after power failure
1 Do not restore state after power failure

The manufacturer defined default value is 0 (Restore state after power failure).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 40: Treshold Change in Power for reporting

Change of power consumption [Watt] reporting threshold Choose by how much power consumption needs to increase or decrease to be reported. Values correspond to percentages, so if 20 is set (by default), the device will report any power consumption changes of 20% or more compared to the last reading.

  • 0 - Power consumption reporting disabled
  • 1 - 100 = 1% - 100% Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible).

NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported, REGARDLESS of percentage set in this parameter.

NOTE: When reporting Watts, module will automatically report also [V] (Voltage) and [A] (Amperes) Values in the range 0 to 100 may be set.

The manufacturer defined default value is 20.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 41: Treshold time for power reporting

Treshold time for power reporting [Watt] Set value refers to the time interval with which power consumption in Watts is reported (0 – 32535 seconds). If 300 is entered (by default), energy consumption reports will be sent to the gateway (hub) every 300 seconds (or 5 minutes).

  • 0 - Power consumption reporting disabled
  • 30 - 32535 = 30 - 32535 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here.

The device is reporting the following values (if there was a change): Power [W], Voltage [V] and Current [A] Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_41_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Smart Plug 16A supports 5 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Reserved for communication with main controller

Association group 1 supports 1 node.

Group 2: Status on/off

Send control command BASIC_SET 0x00/0xFF This group is assigned to the Smart Plug status On/Off. It allows sending the control command BASIC_SET 0x00/0xFF to associated devices whenevert the Smart Plug is turned On or Off.

Association group 2 supports 5 nodes.

Group 3: Load dependent

sending control commands BASIC_SET 0x00/0xFF depending on current load This groups allows to send control commands BASIC_SET 0x00/0xFF to associated devices depending on the current load. This association group is configured through the parameters no. 50, 51 and 52.

Association group 3 supports 5 nodes.

Group 4: Secure Status On/Off

Send control command BASIC_SET 0x00/0xFF This group is equivalent to association group 2, except commands are sent securily encapsulated.

Association group 4 supports 5 nodes.

Group 5: Secure Load dependent

sending control commands BASIC_SET 0x00/0xFF depending on current load This group is equivalent to association group 3, except commands are sent securily encapsulated.

Association group 5 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V5
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1