This describes the Z-Wave device ZMNHAA, manufactured by Goap with the thing type UID of qubino_zmnhaa_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZMNHAA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the ZMNHAA -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Electric meter (kWh) | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
Binary Sensor 1 | sensor_binary1 | Door | Switch |
Binary Sensor 2 | sensor_binary2 | Door | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if a sensor has triggered.
The sensor_binary1
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if a sensor has triggered.
The sensor_binary2
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
The following table provides a summary of the 8 configuration parameters available in the ZMNHAA. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Input 1 switch type | Input 1 switch type |
2 | Input 2 contact type | Input 2 contact type |
3 | Input 3 contact type | Input 3 contact type |
10 | Activate / deactivate functions ALL ON/ALL OFF | Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. |
11 | Automatic turning off relay after set time | 0 - Auto OFF disabled 1 – 65535 = 0,01second – 655,35 seconds Auto OFF enabled with define time, step is 10mseconds |
30 | Saving the state of the relay after a power failure | Saving the state of the relay after a power failure |
40 | Power reporting in Watts on power change | 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power chan |
42 | Power reporting in Watts on power change | default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. |
Input 1 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Input 2 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normaly open) input type |
1 | NC (normaly close) input type |
The manufacturer defined default value is 0
(NO (normaly open) input type).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Input 3 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normaly open) input type |
1 | NC (normaly close) input type |
The manufacturer defined default value is 0
(NO (normaly open) input type).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
The following option values may be configured -:
Value | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255
(ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
0 - Auto OFF disabled 1 – 65535 = 0,01second – 655,35 seconds Auto OFF enabled with define time, step is 10mseconds
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
Saving the state of the relay after a power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | Flush 1relay module saves its state before power failure (it returns t |
1 | Flush 1relay module does not save the state after a power failure, it |
The manufacturer defined default value is 0
(Flush 1relay module saves its state before power failure (it returns t).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power chan
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHAA supports 4 association groups.
Q state and reflecti
Association group 1 supports 4 nodes.
state and reflect
Association group 2 supports 4 nodes.
state and reflect
Association group 3 supports 4 nodes.
Association group 4 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |