ZMNHAA Flush 1 relay

This describes the Z-Wave device ZMNHAA, manufactured by Goap with the thing type UID of qubino_zmnhaa_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

The ZMNHAA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZMNHAA -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Sensor (temperature) sensor_temperature Temperature Number:Temperature
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number
Binary Sensor 1 sensor_binary1 Door Switch
Binary Sensor 2 sensor_binary2 Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number:Temperature item and is in the Temperature category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Binary Sensor 1

Indicates if a sensor has triggered.

The sensor_binary1 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Binary Sensor 2

Indicates if a sensor has triggered.

The sensor_binary2 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the ZMNHAA. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input 1 switch type Input 1 switch type
2 Input 2 contact type Input 2 contact type
3 Input 3 contact type Input 3 contact type
10 Activate / deactivate functions ALL ON/ALL OFF Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
11 Automatic turning off relay after set time 0 - Auto OFF disabled 1 – 65535 = 0,01second – 655,35 seconds Auto OFF enabled with define time, step is 10mseconds
30 Saving the state of the relay after a power failure Saving the state of the relay after a power failure
40 Power reporting in Watts on power change 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power chan
42 Power reporting in Watts on power change default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value.

Parameter 1: Input 1 switch type

Input 1 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Input 2 contact type

Input 2 contact type

The following option values may be configured -:

Value Description
0 NO (normaly open) input type
1 NC (normaly close) input type

The manufacturer defined default value is 0 (NO (normaly open) input type).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Input 3 contact type

Input 3 contact type

The following option values may be configured -:

Value Description
0 NO (normaly open) input type
1 NC (normaly close) input type

The manufacturer defined default value is 0 (NO (normaly open) input type).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 10: Activate / deactivate functions ALL ON/ALL OFF

Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

The following option values may be configured -:

Value Description
0 ALL ON is not active ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Automatic turning off relay after set time

0 - Auto OFF disabled 1 – 65535 = 0,01second – 655,35 seconds Auto OFF enabled with define time, step is 10mseconds

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 30: Saving the state of the relay after a power failure

Saving the state of the relay after a power failure

The following option values may be configured -:

Value Description
0 Flush 1relay module saves its state before power failure (it returns t
1 Flush 1relay module does not save the state after a power failure, it

The manufacturer defined default value is 0 (Flush 1relay module saves its state before power failure (it returns t).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 40: Power reporting in Watts on power change

0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power chan

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 42: Power reporting in Watts on power change

default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value.

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHAA supports 4 association groups.

Group 1: basic on/off (triggered at change of the output

Q state and reflecti

Association group 1 supports 4 nodes.

Group 2: basic on/off (triggered at change of the input I2

state and reflect

Association group 2 supports 4 nodes.

Group 3: basic on/off (triggered at change of the input I3

state and reflect

Association group 3 supports 4 nodes.

Group 4: Controller Updates

Association group 4 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V3
COMMAND_CLASS_METER_V3
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC

Documentation Links