This describes the Z-Wave device ZMNHAD, manufactured by Goap with the thing type UID of qubino_zmnhad_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZMNHAD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This Z-Wave module is used for switching on or off the electrical device (e.g. light or fan). The module can be controlled either through Z-wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of electrical device and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. Supported switches Module supports mono-stable switches (push button) and bi-stable switches. The module is factory set to operate with bi-stable switches.
Module Inclusion (Adding to Z-Wave network)
- Connect module to power supply (with temperature sensor connected -if purchased)
- Enable add/remove mode on main controller
- Auto-inclusion (works forabout 5 seconds after connected to power supply) or
- Press push button I1 three times within 3s (3 times change switch state within 3 seconds) or
- Press service button S (only applicable for 24 V SELV supply voltage) for more than 2 seconds.
NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.
NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module.
Module Exclusion/Reset (Removing from Z-Wavenetwork)
- Connect module to power supply
- Bring module within maximum 1 meter (3 feet) of the main controller,
- Enable add/remove mode on main controller,
- Press push button **I1 **five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
- Press service button **S **(only applicable for 24 V SELV supply voltage) for more than 6 seconds.
By this function all parameters of the module are set to default values and own ID is deleted.
If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.
The following table summarises the channels available for the ZMNHAD -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Binary Sensor | sensor_binary | Door | Switch |
Electric meter (watts) | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Alarm (power) | alarm_power | Door | Switch |
Switch 1 | switch_binary1 | Switch | Switch |
Electric meter (watts) 1 | meter_watts1 | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | Energy | Number |
Binary Sensor I2 | sensor_binary2 | Door | Switch |
Alarm (power) 2 | alarm_power2 | Door | Switch |
Binary Sensor I3 | sensor_binary3 | Door | Switch |
Sensor (temperature) | sensor_temperature3 | Temperature | Number:Temperature |
Sensor (temperature) | sensor_temperature4 | Temperature | Number:Temperature |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if a power alarm is triggered.
The alarm_power
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if a sensor has triggered.
The sensor_binary2
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if a power alarm is triggered.
The alarm_power2
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a sensor has triggered.
The sensor_binary3
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current temperature.
The sensor_temperature3
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current temperature.
The sensor_temperature4
channel supports the Number:Temperature
item and is in the Temperature
category.
The following table provides a summary of the 15 configuration parameters available in the ZMNHAD. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Input 1 switch type | Input 1 switch type |
2 | Input 2 contact type | Input 2 contact type |
3 | Input 3 contact type | Input 3 contact type |
10 | Activate / deactivate functions ALL ON/ALL OFF | Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. |
11 | Automatic turning off relay after set time | When relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). 0 - Auto OFF disabled. 1 |
12 | Automatic turning on relay after set time | When relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). 0 - Auto ON disabled. 1 – |
15 | Automatic turning off / on seconds or milliseconds selection | NOTE: Parameter is the same for turning OFF or ON. |
30 | Saving the state of the relay after a power failure | Saving the state of the relay after a power failure |
40 | Power reporting in Watts on power change | 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: If power chan |
42 | Power reporting in Watts on power change | Set value means time interval (0 – 32535) in seconds, when power report is send. Default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 32535 = 1second – 32535 seconds. Reporting enabled. Power report is send with time |
63 | Output Switch selection | Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC). |
100 | Enable / Disable Endpoints I2 or select Notification Type and Event | Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec |
101 | Enable / Disable Endpoints I3 or select Notification Type and Event | Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec |
110 | Temperature sensor offset settings | Set value is added or subtracted to actual measured value by sensor. 32536 – offset is 0.0C From 1 to 100–value from 0.1°C to 10.0°C is added to actual measured temperature. From 1001 to 1100 – value from -0.1 °C to -10.0 °C is subtracted to actual mea |
120 | Digital temperature sensor reporting | If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.0 – Reporting disabled1- 127 = 0,1°C – 12,7°C, step is 0,1°C |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Input 1 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Input 2 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normaly open) input type |
1 | NC (normaly close) input type |
The manufacturer defined default value is 0
(NO (normaly open) input type).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Input 3 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normaly open) input type |
1 | NC (normaly close) input type |
The manufacturer defined default value is 0
(NO (normaly open) input type).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
The following option values may be configured -:
Value | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255
(ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
When relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). 0 - Auto OFF disabled. 1
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
When relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). 0 - Auto ON disabled. 1 –
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
NOTE: Parameter is the same for turning OFF or ON.
The following option values may be configured -:
Value | Description |
---|---|
0 | Seconds selected |
1 | Milliseconds selected |
The manufacturer defined default value is 0
(Seconds selected).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Saving the state of the relay after a power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | Flush 1relay module saves its state before power failure (it returns t |
1 | Flush 1relay module does not save the state after a power failure, it |
The manufacturer defined default value is 0
(Flush 1relay module saves its state before power failure (it returns t).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: If power chan
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Set value means time interval (0 – 32535) in seconds, when power report is send. Default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 32535 = 1second – 32535 seconds. Reporting enabled. Power report is send with time
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC).
The following option values may be configured -:
Value | Description |
---|---|
0 | When system is turned off the output is 0V (NC). |
1 | When system is turned off the output is 230V or 24V (NO). |
The manufacturer defined default value is 0
(When system is turned off the output is 0V (NC).).
This parameter has the configuration ID config_63_1
and is of type INTEGER
.
Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec
The following option values may be configured -:
Value | Description |
---|---|
0 | Endpoint, I2 disabled |
1 | Home Security; Motion Detection, unknown loc. |
2 | Carbon Monoxide; Carbon Monoxide detected, unknown location. |
3 | Carbon Dioxide; Carbon Dioxide detected, unknown location. |
4 | Water Alarm; Water Leak detected, unknown lo.. |
5 | Heat Alarm; Overheat detected, unknown loc. |
6 | Smoke Alarm; Smoke detected, unknown loc. |
9 | Sensor binary. |
The manufacturer defined default value is 1
(Home Security; Motion Detection, unknown loc.).
This parameter has the configuration ID config_100_1
and is of type INTEGER
.
Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec
The following option values may be configured -:
Value | Description |
---|---|
0 | Endpoint, I3 disabled |
1 | Home Security; Motion Detection, unknown loc. |
2 | Carbon Monoxide; Carbon Monoxide detected, unknown location. |
3 | Carbon Dioxide; Carbon Dioxide detected, unknown location. |
4 | Water Alarm; Water Leak detected, unknown lo.. |
5 | Heat Alarm; Overheat detected, unknown loc. |
6 | Smoke Alarm; Smoke detected, unknown loc. |
9 | Sensor binary. |
The manufacturer defined default value is 1
(Home Security; Motion Detection, unknown loc.).
This parameter has the configuration ID config_101_1
and is of type INTEGER
.
Set value is added or subtracted to actual measured value by sensor. 32536 – offset is 0.0C From 1 to 100–value from 0.1°C to 10.0°C is added to actual measured temperature. From 1001 to 1100 – value from -0.1 °C to -10.0 °C is subtracted to actual mea
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 32536
.
This parameter has the configuration ID config_110_2
and is of type INTEGER
.
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.0 – Reporting disabled1- 127 = 0,1°C – 12,7°C, step is 0,1°C
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_120_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHAD supports 9 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline group (reserved for communication with the main controller
Association group 1 supports 1 node.
state and reflectin
Association group 2 supports 16 nodes.
state and reflecti
Association group 3 supports 16 nodes.
state and r
Association group 4 supports 16 nodes.
state and reflect
Association group 5 supports 16 nodes.
state and reflecti
Association group 6 supports 16 nodes.
state and re
Association group 7 supports 16 nodes.
state and r
Association group 8 supports 16 nodes.
Association group 9 supports 16 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |