This describes the Z-Wave device ZMNHLA, manufactured by Goap with the thing type UID of qubino_zmnhla_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The ZMNHLA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the ZMNHLA -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Electric meter (watts) | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Thermostat mode | thermostat_mode | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature |
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
The following table provides a summary of the 32 configuration parameters available in the ZMNHLA. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Input 1 switch type | Input 1 switch type |
2 | Input 2 switch type | Input 2 switch type |
3 | Input 3 switch type | Input 3 switch type |
4 | Input 1 contact type | Input 1 contact type |
5 | Input 2 contact type | Input 2 contact type |
6 | Input 3 contact type | Input 3 contact type |
10 | Activate / deactivate functions ALL ON/ALL OFF | Respond to ALL ON/ALL OFF |
11 | I1 Functionality Selection | Default Value = 1. 65535 – Input I1 does not influence on the heat/cool process. 1 - Input I1 changes the mode of the thermostat between OFF and AUTO. In this case function on flood sensor (if connected) is disabled. 2 - inpu |
12 | I2 Functionality Selection | Default = 65535, 65535 - I2 does not influence on the heat/cool process, From From 0 to 990 - Temperature set point from 0.0 C to 99.0 C. When I2 is pressed, the temperature set point is automatically set to value defined here. In |
13 | I3 Functionality Selection | Default Value = 65535. 65535 – Input I3 does not influence on the heat/cool process. 1 - Input I3 changes the mode of the thermostat between OFF and AUTO. In this case function on window sensor is disabled. 2 - input I3 influ |
40 | Power reporting in Watts on power change | Default Value = 0. 0 – Reporting Disabled 1 - 100 = 1% - 100% Reporting enabled. Power report is sent (pushed) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in |
42 | Power reporting in Watts by timer interval | Default Value = 300. 0 – Reporting Disabled 1 - 32767 = 1 second - 32767 seconds Reporting enabled. Power report is sent with time interval set by entered value. |
45 | Antifreeze | Set value at which temperature the device will be turned on even if the termpearture was manually set to off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 C to 12.7 C and from 128 to 254 means from -0.1 C to -12.6 C |
50 | PWM Maximum Value | 2 - 100 = 2% - 100%, step is 1% Max PWM set by entered value. Default = 100. The Maximum level may not be lower than the minimum level. |
51 | PWM Minimum Value | 1 - 99 = 1% - 99%, step is 1% Minimum PWM set by entered value. Default = 0. The Minimum level may exceed the maximum level. |
52 | PWM Cycle Duration | 1 - 127 = 1-127 seconds, step is 1s PWM Cycle Duration set by entered value. Default = 10. NOTE:PWM Cycle duration defines the summary of all ON plus OFF time periods. For example if Output is set to 70% with PWM cycle duration of 20s, |
53 | PID Value Inside Deadband | When value is set to ZERO PID inside deadband is forced to zero. LAST VALUE means PID remains on same level as was before entering into deadband. |
54 | PID Deadband | 0 - 127 = 0.0C - 12.7C step is 0.1 C This parameter defines the zone where PID is not active. If the temperature difference between actual and setpoint is bigger than PID deadband, then the PID will start to regulate the system, otherw |
55 | Integral Sampling Time | 0 - 127 = 0s -127s step is 1s Parameter defines the time between samples. On each sample the controller captures difference between SP-act. |
56 | P Parameter | 0 - 1000 P value step is 1. Default = 100 |
57 | I Parameter | 0 - 1000 - 0s I value step is 1. Default = 1 |
58 | D Parameter | 0 - 1000 - 0s D value step is 1. Default = 1 |
59 | Thermostat Mode | |
60 | Too low temperature limit | 1 - 1000 = 0.1 C - 100.0 C step is 0.1 C Too low temperature limit is set by entered value. In case measured temperature is below set value, module sends BasicSet value. Default = 50 |
61 | Too high temperature limit | 1 - 1000 = 0.1 C - 100.0 C step is 0.1 C Too high temperature limit is set by entered value. In case measured temperature is higher than set value, module sends BasicSet value. Default = 700 |
63 | Output Switch Selection | |
70 | Input 1 Status on delay | 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2! |
71 | Input 1 Status off delay | 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2! |
72 | Input 2 Status on delay | 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000! |
73 | Input 2 Status off delay | 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000! |
74 | Input 3 Status on delay | 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2! |
75 | Input 3 Status off delay | 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2! |
Input 1 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Input 2 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Input 3 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Input 1 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Input 2 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Input 3 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Respond to ALL ON/ALL OFF Flush PWM thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:
Value | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255
(ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Default Value = 1. 65535 – Input I1 does not influence on the heat/cool process. 1 - Input I1 changes the mode of the thermostat between OFF and AUTO. In this case function on flood sensor (if connected) is disabled. 2 - inpu
Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
Default = 65535, 65535 - I2 does not influence on the heat/cool process, From From 0 to 990 - Temperature set point from 0.0 C to 99.0 C. When I2 is pressed, the temperature set point is automatically set to value defined here. In
Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 65535
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Default Value = 65535. 65535 – Input I3 does not influence on the heat/cool process. 1 - Input I3 changes the mode of the thermostat between OFF and AUTO. In this case function on window sensor is disabled. 2 - input I3 influ
Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 65535
.
This parameter has the configuration ID config_13_2
and is of type INTEGER
.
Default Value = 0. 0 – Reporting Disabled 1 - 100 = 1% - 100% Reporting enabled. Power report is sent (pushed) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Default Value = 300. 0 – Reporting Disabled 1 - 32767 = 1 second - 32767 seconds Reporting enabled. Power report is sent with time interval set by entered value.
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
Set value at which temperature the device will be turned on even if the termpearture was manually set to off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 C to 12.7 C and from 128 to 254 means from -0.1 C to -12.6 C
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_45_1
and is of type INTEGER
.
2 - 100 = 2% - 100%, step is 1% Max PWM set by entered value. Default = 100. The Maximum level may not be lower than the minimum level.
Values in the range 2 to 100 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_50_1
and is of type INTEGER
.
1 - 99 = 1% - 99%, step is 1% Minimum PWM set by entered value. Default = 0. The Minimum level may exceed the maximum level.
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_51_1
and is of type INTEGER
.
1 - 127 = 1-127 seconds, step is 1s PWM Cycle Duration set by entered value. Default = 10. NOTE:PWM Cycle duration defines the summary of all ON plus OFF time periods. For example if Output is set to 70% with PWM cycle duration of 20s,
Values in the range 1 to 127 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_52_1
and is of type INTEGER
.
When value is set to ZERO PID inside deadband is forced to zero. LAST VALUE means PID remains on same level as was before entering into deadband.
The following option values may be configured -:
Value | Description |
---|---|
0 | PID value equals ZERO |
1 | PID value set to LAST VALUE |
The manufacturer defined default value is 0
(PID value equals ZERO).
This parameter has the configuration ID config_53_1
and is of type INTEGER
.
0 - 127 = 0.0C - 12.7C step is 0.1 C This parameter defines the zone where PID is not active. If the temperature difference between actual and setpoint is bigger than PID deadband, then the PID will start to regulate the system, otherw
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_54_1
and is of type INTEGER
.
0 - 127 = 0s -127s step is 1s Parameter defines the time between samples. On each sample the controller captures difference between SP-act.
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_55_1
and is of type INTEGER
.
0 - 1000 P value step is 1. Default = 100
Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_56_2
and is of type INTEGER
.
0 - 1000 - 0s I value step is 1. Default = 1
Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_57_2
and is of type INTEGER
.
0 - 1000 - 0s D value step is 1. Default = 1
Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_58_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Heat Mode |
1 | Cool Mode |
The manufacturer defined default value is 0
(Heat Mode).
This parameter has the configuration ID config_59_1
and is of type INTEGER
.
1 - 1000 = 0.1 C - 100.0 C step is 0.1 C Too low temperature limit is set by entered value. In case measured temperature is below set value, module sends BasicSet value. Default = 50
Values in the range 1 to 1000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_60_2
and is of type INTEGER
.
1 - 1000 = 0.1 C - 100.0 C step is 0.1 C Too high temperature limit is set by entered value. In case measured temperature is higher than set value, module sends BasicSet value. Default = 700
Values in the range 1 to 1000 may be set.
The manufacturer defined default value is 700
.
This parameter has the configuration ID config_61_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | When system is turned off the output is 0V (NC) |
1 | When system is turned off the output is 230V (NO) |
The manufacturer defined default value is 0
(When system is turned off the output is 0V (NC)
).
This parameter has the configuration ID config_63_1
and is of type INTEGER
.
1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2!
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_70_2
and is of type INTEGER
.
1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2!
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_71_2
and is of type INTEGER
.
1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000!
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_72_2
and is of type INTEGER
.
1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000!
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_73_2
and is of type INTEGER
.
1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2!
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_74_2
and is of type INTEGER
.
1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2!
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_75_2
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHLA supports 6 association groups.
Association group 1 supports 16 nodes.
Association group 2 supports 16 nodes.
Association group 3 supports 16 nodes.
Association group 4 supports 16 nodes.
Association group 5 supports 16 nodes.
Association group 6 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |