This describes the Z-Wave device ZMNHOD, manufactured by Goap with the thing type UID of qubino_zmnhod_00_000
.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The ZMNHOD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the ZMNHOD -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Blinds control | blinds_control | Blinds | Rollershutter |
Binary Sensor | sensor_binary | Door | Switch |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Electric meter (watts) | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Switch 1 | switch_binary1 | Switch | Switch |
Blinds control 1 | blinds_control1 | Blinds | Rollershutter |
Electric meter (watts) 1 | meter_watts1 | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | Energy | Number |
Sensor (temperature) 2 | sensor_temperature2 | Temperature | Number:Temperature |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Provides start / stop control of blinds.
The blinds_control
channel supports the Rollershutter
item and is in the Blinds
category.
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
Provides start / stop control of blinds.
The blinds_control1
channel supports the Rollershutter
item and is in the Blinds
category.
Indicates the instantaneous power consumption.
The meter_watts1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current temperature.
The sensor_temperature2
channel supports the Number:Temperature
item and is in the Temperature
category.
The following table provides a summary of the 14 configuration parameters available in the ZMNHOD. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
10 | Activate/deactivate functions ALL ON / ALL OFF | Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. |
40 | Power reporting in Watts on power change for Q1 or Q2 | Set value 0 – 100 as percentage. |
Available configuration parameters. |
-
0 = Reporting Disabled
-
1–100 = 1% - 100% Reporting enabled Power report is sent only when actual power (in Watts) in real | | 42 | Power reporting in Watts by time interval for Q1 or Q2 | Set value determines interval in seconds, when power report is send.
Available configuration parameters. -
default value 300 = 300s
-
0 – Reporting Disabled
-
1 – 32767 = 1 second – 32767 seconds | | 71 | Operating modes | This parameter defines selection between two available operating modes.
NOTE: When setting parameter, module needs to be excluded and included again! Please check detailed description in this manual. | | 72 | Slats tilting full turn time | This parameter defines the time necessary for slats to make full turn (180 degrees)
NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining. -
default value 15 | | 73 | Slats position | This parameter defines slats position after up/down movement through Z-wave or push-buttons. | | 74 | Motor moving up/down time | This parameter defines shutter motor moving time of complete opening or complete closing.
NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining. -
defau | | 76 | Motor operation detection | Power threshold to be interpreted when motor reaches the limit switch.
-
default value 6 = 0,6W
-
5 - 100 (0,5W - 10W), step is 0,1W.
-
The value 0 means reaching a limit switch will not be detected | | 78 | Forced Shutter DC calibration | Setting value 0 or 1 a Shutter DC module enters the calibration mode.
When calibration process is finished, completing full cycle - up, down and up, set parameter 78 back to default of 0. | | 85 | Power consumption max delay time | This parameter defines the max time before motor power consumption is read after one of the relays is switched ON.
If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, mo | | 86 | Power consumption at limit switch delay time | This parameter defines the max time at limit switch, when power consumption is below power threshold.
If the power consumption during this time is below power threshold (par. 76), the active output will switch off, means that limit sw | | 90 | Time delay for next motor movement | This parameter defines the minimum time delay between next motor movemen.
(minimum time between switching motor off and on again) -
default value 5 = 500ms
-
1 – 30 = 0,1seconds – 3seconds (100ms resolution) | | 110 | Temperature sensor offset settings | Set value is added or subtracted to actual measured value by sensor. default value 32536 32536 – offset is 0.0C From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature. | | 120 | Digital temperature sensor reporting | If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.
-
Default value 5 = 0,5°C
-
32536 – offset is 0.0C
-
0 – Reporting disabled | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
The following option values may be configured -:
Value | Description |
---|---|
0 | ALL ON is not active, ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON is not active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255
(ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Set value 0 – 100 as percentage.
Available configuration parameters.
- 0 = Reporting Disabled
- 1–100 = 1% - 100% Reporting enabled Power report is sent only when actual power (in Watts) in real
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Set value determines interval in seconds, when power report is send.
Available configuration parameters.
- default value 300 = 300s
- 0 – Reporting Disabled
- 1 – 32767 = 1 second – 32767 seconds
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
This parameter defines selection between two available operating modes.
NOTE: When setting parameter, module needs to be excluded and included again! Please check detailed description in this manual.
The following option values may be configured -:
Value | Description |
---|---|
0 | Shutter mode. |
1 | Venetian mode (up/down and slate rotation) |
The manufacturer defined default value is 0
(Shutter mode.).
This parameter has the configuration ID config_71_1
and is of type INTEGER
.
This parameter defines the time necessary for slats to make full turn (180 degrees)
NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.
- default value 15
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 150
.
This parameter has the configuration ID config_72_2
and is of type INTEGER
.
This parameter defines slats position after up/down movement through Z-wave or push-buttons.
The following option values may be configured -:
Value | Description |
---|---|
0 | Slats return to previously set position only in case of Z-wave control |
1 | Slats return to previously set position in case of Z-wave control, pus |
The manufacturer defined default value is 1
(Slats return to previously set position in case of Z-wave control, pus).
This parameter has the configuration ID config_73_1
and is of type INTEGER
.
This parameter defines shutter motor moving time of complete opening or complete closing.
NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.
- defau
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_74_2
and is of type INTEGER
.
Power threshold to be interpreted when motor reaches the limit switch.
- default value 6 = 0,6W
- 5 - 100 (0,5W - 10W), step is 0,1W.
- The value 0 means reaching a limit switch will not be detected
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_76_1
and is of type INTEGER
.
Setting value 0 or 1 a Shutter DC module enters the calibration mode.
When calibration process is finished, completing full cycle - up, down and up, set parameter 78 back to default of 0.
The following option values may be configured -:
Value | Description |
---|---|
0 | Default |
1 | Start calibration process. |
The manufacturer defined default value is 0
(Default).
This parameter has the configuration ID config_78_1
and is of type INTEGER
.
This parameter defines the max time before motor power consumption is read after one of the relays is switched ON.
If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, mo
Values in the range 3 to 50 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_85_1
and is of type INTEGER
.
This parameter defines the max time at limit switch, when power consumption is below power threshold.
If the power consumption during this time is below power threshold (par. 76), the active output will switch off, means that limit sw
Values in the range 3 to 50 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_86_1
and is of type INTEGER
.
This parameter defines the minimum time delay between next motor movemen.
(minimum time between switching motor off and on again)
- default value 5 = 500ms
- 1 – 30 = 0,1seconds – 3seconds (100ms resolution)
Values in the range 1 to 30 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
Set value is added or subtracted to actual measured value by sensor. default value 32536 32536 – offset is 0.0C From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature.
Values in the range 1 to 32536 may be set.
The manufacturer defined default value is 32536
.
This parameter has the configuration ID config_110_2
and is of type INTEGER
.
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.
- Default value 5 = 0,5°C
- 32536 – offset is 0.0C
- 0 – Reporting disabled
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_120_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHOD supports 9 association groups.
Association group 1 supports 1 node.
Triggered at change of the input I1 state and reflecting its state
Association group 2 supports 16 nodes.
Triggered at change of the input I2 state and reflecting its state
Association group 3 supports 16 nodes.
Triggered at sensing moving direction of roller up=FF, down=0
Association group 4 supports 16 nodes.
Triggered at reaching roller position bottom=FF, top=0
Association group 5 supports 16 nodes.
Triggered at reaching roller position bottom=FF, not bottom=0
Association group 6 supports 16 nodes.
triggered at changes of value of the Flush Shutter DC position
Association group 7 supports 16 nodes.
Triggered at changes of value of slats tilting position
Association group 8 supports 16 nodes.
Triggered at change of temperature sensor
Association group 9 supports 16 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |