ZMNHOD Flush Shutter DC

This describes the Z-Wave device ZMNHOD, manufactured by Goap with the thing type UID of qubino_zmnhod_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

ZMNHOD product image

The ZMNHOD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZMNHOD -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Blinds control blinds_control Blinds Rollershutter
Binary Sensor sensor_binary Door Switch
Sensor (temperature) sensor_temperature Temperature Number:Temperature
Electric meter (watts) meter_watts Energy Number
Electric meter (kWh) meter_kwh Energy Number
Switch 1 switch_binary1 Switch Switch
Blinds control 1 blinds_control1 Blinds Rollershutter
Electric meter (watts) 1 meter_watts1 Energy Number
Electric meter (kWh) 1 meter_kwh1 Energy Number
Sensor (temperature) 2 sensor_temperature2 Temperature Number:Temperature

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Blinds control

Provides start / stop control of blinds.

The blinds_control channel supports the Rollershutter item and is in the Blinds category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number:Temperature item and is in the Temperature category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Blinds control 1

Provides start / stop control of blinds.

The blinds_control1 channel supports the Rollershutter item and is in the Blinds category.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel supports the Number:Temperature item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 14 configuration parameters available in the ZMNHOD. Detailed information on each parameter can be found in the sections below.

Param Name Description
10 Activate/deactivate functions ALL ON / ALL OFF Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
40 Power reporting in Watts on power change for Q1 or Q2 Set value 0 – 100 as percentage.
Available configuration parameters.
  • 0 = Reporting Disabled

  • 1–100 = 1% - 100% Reporting enabled Power report is sent only when actual power (in Watts) in real | | 42 | Power reporting in Watts by time interval for Q1 or Q2 | Set value determines interval in seconds, when power report is send.
    Available configuration parameters.

  • default value 300 = 300s

  • 0 – Reporting Disabled

  • 1 – 32767 = 1 second – 32767 seconds | | 71 | Operating modes | This parameter defines selection between two available operating modes.
    NOTE: When setting parameter, module needs to be excluded and included again! Please check detailed description in this manual. | | 72 | Slats tilting full turn time | This parameter defines the time necessary for slats to make full turn (180 degrees)
    NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.

  • default value 15 | | 73 | Slats position | This parameter defines slats position after up/down movement through Z-wave or push-buttons. | | 74 | Motor moving up/down time | This parameter defines shutter motor moving time of complete opening or complete closing.
    NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.

  • defau | | 76 | Motor operation detection | Power threshold to be interpreted when motor reaches the limit switch.

  • default value 6 = 0,6W

  • 5 - 100 (0,5W - 10W), step is 0,1W.

  • The value 0 means reaching a limit switch will not be detected | | 78 | Forced Shutter DC calibration | Setting value 0 or 1 a Shutter DC module enters the calibration mode.
    When calibration process is finished, completing full cycle - up, down and up, set parameter 78 back to default of 0. | | 85 | Power consumption max delay time | This parameter defines the max time before motor power consumption is read after one of the relays is switched ON.
    If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, mo | | 86 | Power consumption at limit switch delay time | This parameter defines the max time at limit switch, when power consumption is below power threshold.
    If the power consumption during this time is below power threshold (par. 76), the active output will switch off, means that limit sw | | 90 | Time delay for next motor movement | This parameter defines the minimum time delay between next motor movemen.
    (minimum time between switching motor off and on again)

  • default value 5 = 500ms

  • 1 – 30 = 0,1seconds – 3seconds (100ms resolution) | | 110 | Temperature sensor offset settings | Set value is added or subtracted to actual measured value by sensor. default value 32536 32536 – offset is 0.0C From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature. | | 120 | Digital temperature sensor reporting | If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.

  • Default value 5 = 0,5°C

  • 32536 – offset is 0.0C

  • 0 – Reporting disabled | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |

Parameter 10: Activate/deactivate functions ALL ON / ALL OFF

Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

The following option values may be configured -:

Value Description
0 ALL ON is not active, ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON is not active ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 40: Power reporting in Watts on power change for Q1 or Q2

Set value 0 – 100 as percentage.
Available configuration parameters.

  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporting enabled Power report is sent only when actual power (in Watts) in real

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 42: Power reporting in Watts by time interval for Q1 or Q2

Set value determines interval in seconds, when power report is send.
Available configuration parameters.

  • default value 300 = 300s
  • 0 – Reporting Disabled
  • 1 – 32767 = 1 second – 32767 seconds

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 71: Operating modes

This parameter defines selection between two available operating modes.
NOTE: When setting parameter, module needs to be excluded and included again! Please check detailed description in this manual.

The following option values may be configured -:

Value Description
0 Shutter mode.
1 Venetian mode (up/down and slate rotation)

The manufacturer defined default value is 0 (Shutter mode.).

This parameter has the configuration ID config_71_1 and is of type INTEGER.

Parameter 72: Slats tilting full turn time

This parameter defines the time necessary for slats to make full turn (180 degrees)
NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.

  • default value 15

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 150.

This parameter has the configuration ID config_72_2 and is of type INTEGER.

Parameter 73: Slats position

This parameter defines slats position after up/down movement through Z-wave or push-buttons.

The following option values may be configured -:

Value Description
0 Slats return to previously set position only in case of Z-wave control
1 Slats return to previously set position in case of Z-wave control, pus

The manufacturer defined default value is 1 (Slats return to previously set position in case of Z-wave control, pus).

This parameter has the configuration ID config_73_1 and is of type INTEGER.

Parameter 74: Motor moving up/down time

This parameter defines shutter motor moving time of complete opening or complete closing.
NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.

  • defau

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_74_2 and is of type INTEGER.

Parameter 76: Motor operation detection

Power threshold to be interpreted when motor reaches the limit switch.

  • default value 6 = 0,6W
  • 5 - 100 (0,5W - 10W), step is 0,1W.
  • The value 0 means reaching a limit switch will not be detected

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_76_1 and is of type INTEGER.

Parameter 78: Forced Shutter DC calibration

Setting value 0 or 1 a Shutter DC module enters the calibration mode.
When calibration process is finished, completing full cycle - up, down and up, set parameter 78 back to default of 0.

The following option values may be configured -:

Value Description
0 Default
1 Start calibration process.

The manufacturer defined default value is 0 (Default).

This parameter has the configuration ID config_78_1 and is of type INTEGER.

Parameter 85: Power consumption max delay time

This parameter defines the max time before motor power consumption is read after one of the relays is switched ON.
If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, mo

Values in the range 3 to 50 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_85_1 and is of type INTEGER.

Parameter 86: Power consumption at limit switch delay time

This parameter defines the max time at limit switch, when power consumption is below power threshold.
If the power consumption during this time is below power threshold (par. 76), the active output will switch off, means that limit sw

Values in the range 3 to 50 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_86_1 and is of type INTEGER.

Parameter 90: Time delay for next motor movement

This parameter defines the minimum time delay between next motor movemen.
(minimum time between switching motor off and on again)

  • default value 5 = 500ms
  • 1 – 30 = 0,1seconds – 3seconds (100ms resolution)

Values in the range 1 to 30 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor. default value 32536 32536 – offset is 0.0C From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature.

Values in the range 1 to 32536 may be set.

The manufacturer defined default value is 32536.

This parameter has the configuration ID config_110_2 and is of type INTEGER.

Parameter 120: Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.

  • Default value 5 = 0,5°C
  • 32536 – offset is 0.0C
  • 0 – Reporting disabled

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHOD supports 9 association groups.

Group 1: Default reporting group

Association group 1 supports 1 node.

Group 2: Basic on/off

Triggered at change of the input I1 state and reflecting its state

Association group 2 supports 16 nodes.

Group 3: Basic on/off

Triggered at change of the input I2 state and reflecting its state

Association group 3 supports 16 nodes.

Group 4: Basic on/off

Triggered at sensing moving direction of roller up=FF, down=0

Association group 4 supports 16 nodes.

Group 5: Basic on/off

Triggered at reaching roller position bottom=FF, top=0

Association group 5 supports 16 nodes.

Group 6: Basic on/off

Triggered at reaching roller position bottom=FF, not bottom=0

Association group 6 supports 16 nodes.

Group 7: Multilevel set

triggered at changes of value of the Flush Shutter DC position

Association group 7 supports 16 nodes.

Group 8: Multilevel set

Triggered at changes of value of slats tilting position

Association group 8 supports 16 nodes.

Group 9: Multilevel sensor report

Triggered at change of temperature sensor

Association group 9 supports 16 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links