Reitz 05431 Duewi ZW BJ ES 1000 / Reitz 05431 / ZWave.me 05457 Single button wall switch

This describes the Z-Wave device Reitz 05431, manufactured by Reitz-Group.de with the thing type UID of reitz_05431_00_000.

The Reitz 05431 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the Reitz 05431 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the Reitz 05431. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Set LED indication mode
2 Automatic switch off If not zero, automatically switch off after a user defined time
3 Function of RF off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the
4 Switch on dimming by buttons Defines if the switch should change it state to on/off if it is dimmed by buttons
5 Switch on dimming by buttons Defines if the switch should restore switch state to the last state prior to device power off (power cycle).
10 Typical click timeout Typical time used to differentiate click, hold, double and triple clicks
Defined in 10ms ticks.
11 Invert buttons
12 Switch by buttons If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch w
13 Action on button single press or hold Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast.
14 Action on button double press or hold Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be
15 Send the following switch all commands
16 What to do on button Down press
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Set LED indication mode

The following option values may be configured -:

Value Description
0 Disabled
1 Show switch state
2 Night mode
3 Remote by indicator command class

The manufacturer defined default value is 3 (Remote by indicator command class).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Automatic switch off

If not zero, automatically switch off after a user defined time

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Function of RF off command

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the

The following option values may be configured -:

Value Description
0 Switch OFF
1 Ignore
2 Switch ON
3 Switch on if load is off else switch off

The manufacturer defined default value is 0 (Switch OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Switch on dimming by buttons

Defines if the switch should change it state to on/off if it is dimmed by buttons

The following option values may be configured -:

Value Description
0 No
1 Yes (Default)

The manufacturer defined default value is 1 (Yes (Default)).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Switch on dimming by buttons

Defines if the switch should restore switch state to the last state prior to device power off (power cycle).

The following option values may be configured -:

Value Description
0 No, turn off
1 Yes (Default)

The manufacturer defined default value is 1 (Yes (Default)).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 10: Typical click timeout

Typical time used to differentiate click, hold, double and triple clicks
Defined in 10ms ticks.

Values in the range 1 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Invert buttons

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Switch by buttons

If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch w

The following option values may be configured -:

Value Description
0 No
1 By single press and hold
2 By double press and hold

The manufacturer defined default value is 1 (By single press and hold).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Action on button single press or hold

Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast.

The following option values may be configured -:

Value Description
0 Disabled
1 Switch On, Off and dim using Basic Set
2 Switch All
3 Send Scenes
4 Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)
5 Send Preconfigured Scenes

The manufacturer defined default value is 4 (Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Action on button double press or hold

Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be

The following option values may be configured -:

Value Description
0 Disabled (Default)
1 Switch On, Off and dim using Basic Set
2 Switch All
3 Send Scenes
4 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
5 Send Preconfigured Scenes

The manufacturer defined default value is 0 (Disabled (Default)).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Send the following switch all commands

The following option values may be configured -:

Value Description
-1 Switch all on and off
0 Switch off only
1 Switch on only

The manufacturer defined default value is 1 (Switch on only).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: What to do on button Down press

The following option values may be configured -:

Value Description
0 Switch off (Default)
1 Switch On if load is Off, else switch Off
3 Switch on

The manufacturer defined default value is 1 (Switch On if load is Off, else switch Off).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Reitz 05431 supports 3 association groups.

Group 1: Group 1

Association group 1 supports 8 nodes.

Group 2: Group 2

Association group 2 supports 8 nodes.

Group 3: Group 3

Association group 3 supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_HAIL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1

Documentation Links