This describes the Z-Wave device CT100 Plus, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct100plus_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The CT100 Plus supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the CT100 Plus -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Door | Switch |
Sensor (relative humidity) | sensor_relhumidity | Humidity | Number |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (dry air) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (furnace) | thermostat_setpoint | Temperature | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | ||
Battery Level | battery-level | Battery | Number |
Clock Time Offset | time_offset | Temperature | Number |
Sensor (relative humidity) 1 | sensor_relhumidity1 | Humidity | Number |
Sensor (temperature) 1 | sensor_temperature1 | Temperature | Number:Temperature |
Thermostat mode 1 | thermostat_mode1 | Temperature | Number |
Operating State 1 | thermostat_state1 | Temperature | Number |
Setpoint (heating) 1 | thermostat_setpoint1 | Temperature | Number:Temperature |
Setpoint (cooling) 1 | thermostat_setpoint1 | Temperature | Number:Temperature |
Setpoint (dry air) 1 | thermostat_setpoint1 | Temperature | Number:Temperature |
Setpoint (furnace) 1 | thermostat_setpoint1 | Temperature | Number:Temperature |
Thermostat fan mode 1 | thermostat_fanmode1 | ||
Thermostat fan state 1 | thermostat_fanstate1 | ||
Clock Time Offset 1 | time_offset1 | Temperature | Number |
Sensor (relative humidity) 2 | sensor_relhumidity2 | Humidity | Number |
Sensor (temperature) 2 | sensor_temperature2 | Temperature | Number:Temperature |
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current relative humidity.
The sensor_relhumidity
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity1
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current temperature.
The sensor_temperature1
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode1
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state1
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint1
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel supports the Number:Temperature
item and is in the Temperature
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Provides the current time difference for the devices time.
The time_offset1
channel supports the Number
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity2
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current temperature.
The sensor_temperature2
channel supports the Number:Temperature
item and is in the Temperature
category.
The following table provides a summary of the 15 configuration parameters available in the CT100 Plus. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Temperature Reporting Threshold | Reporting threshold for changes in the ambient temperature |
2 | HVAC Settings | Configured HVAC settings |
3 | Utility Lock Enable/Disable | Prevents setpoint changes at thermostat |
4 | Power Status | C-Wire / Battery Status |
5 | Humidity Reporting Threshold | Reporting threshold for changes in the relative humidity |
6 | Auxiliary/Emergency | Enables or disables auxiliary / emergency heating |
7 | Thermostat Swing Temperature | Variance allowed from setpoint to engage HVAC |
8 | Thermostat Diff Temperature | Configures additional stages |
9 | Thermostat Recovery Mode | Fast or Economy recovery mode |
10 | Temperature Filter Upper Bound | Upper/Lower bounds for thermostat temperature reporting |
10 | Temperature Filter Lower Bound Unit | Upper/Lower bounds for thermostat temperature reporting |
10 | Temperature Filter Upper Bound Unit | Upper/Lower bounds for thermostat temperature reporting |
10 | Temperature Filter Lower Bound | Upper/Lower bounds for thermostat temperature reporting |
11 | Simple UI Mode | Simple mode enable/disable |
12 | Multicast | Enable or disables Multicast |
Reporting threshold for changes in the ambient temperature This value determines the reporting threshold when association reporting is enabled. Unsupported values will be ignored. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | 0.5° F |
2 | 1.0° F |
3 | 1.5° F |
4 | 2.0° F |
The manufacturer defined default value is 2
(1.0° F).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Configured HVAC settings
Byte 1 = HVAC Setup: Normal (0x01) or Heat Pump (0x02)
Byte 2 = Aux Setup (Gas (0x01) or Electric (0x02)) & Number of Auxiliary Stages (Heat Pump)/Number of Heat Stages (Normal)
Byte 3 = Number of Heat Pump Stages
Byte 4 = Number of Cool Stages
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_4
and is of type INTEGER
.
This is a read only parameter.
Prevents setpoint changes at thermostat If set to 0, the utility lock is disabled, all other values, 1-255, will enable the utility lock. This will prevent changes to the setpoint at the thermostat screen. The following option values may be configured -:
Value | Description |
---|---|
0 | Utility lock disabled |
1 | Utility lock enabled |
The manufacturer defined default value is 0
(Utility lock disabled).
This parameter has the configuration ID config_3_1_wo
and is of type INTEGER
.
This is a write only parameter.
C-Wire / Battery Status If 0x01, the thermostat is powered by a C-wire. If 0x02, the thermostat is powered by batteries. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
This is a read only parameter.
Reporting threshold for changes in the relative humidity This value determines the reporting threshold when association reporting is enabled. Unsupported values will be ignored. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | 3% RH |
2 | 5% RH |
3 | 10% RH |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Enables or disables auxiliary / emergency heating If set to 0, auxiliary / emergency heat is disabled, all other values, 1-255, will enable the auxiliary / emergency heat. This can only be enabled when the thermostat is set to Heat Pump mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Auxiliary/Emergency heat disabled |
1 | Auxiliary/Emergency heat enabled |
The manufacturer defined default value is 0
(Auxiliary/Emergency heat disabled).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Variance allowed from setpoint to engage HVAC The thermostat swing temperature is in units of 0.5 degrees Fahrenheit. The following option values may be configured -:
Value | Description |
---|---|
1 | 0.5° F |
2 | 1.0° F |
3 | 1.5° F |
4 | 2.0° F |
5 | 2.5° F |
6 | 3.0° F |
7 | 3.5° F |
8 | 4.0° F |
The manufacturer defined default value is 2
(1.0° F).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Configures additional stages Sets the differential temperature for multi-stage HVAC systems. The differential temperature delta defines when the thermostat will turn on additional stages. This command configures both the heat and cool differential temperatures. The following option values may be configured -:
Value | Description |
---|---|
4 | 2.0° F |
8 | 4.0° F |
12 | 6.0° F |
The manufacturer defined default value is 4
(2.0° F).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Fast or Economy recovery mode The Thermostat Recovery Mode can be either fast (1) or economy (2). The following option values may be configured -:
Value | Description |
---|---|
1 | Fast recovery mode |
2 | Economy recovery mode |
The manufacturer defined default value is 2
(Economy recovery mode).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Upper/Lower bounds for thermostat temperature reporting The thermostat will report ambient temperature changes for temperature values greater than the upper bound. This field must be between 0F and 124F. By default, this value is 0F (report all temperature changes). Values in the range 0 to 124 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_4_000000FF
and is of type INTEGER
.
Upper/Lower bounds for thermostat temperature reporting Specifies unit for lower bound parameter. If set to 1, lower bound is Celsius. If set to 9, lower bound is Fahrenheit. The following option values may be configured -:
Value | Description |
---|---|
1 | Celsius |
9 | Fahreheit |
The manufacturer defined default value is 9
(Fahreheit).
This parameter has the configuration ID config_10_4_0000F000
and is of type INTEGER
.
Upper/Lower bounds for thermostat temperature reporting Specifies unit for upper bound parameter. If set to 1, upper bound is Celsius. If set to 9, upper bound is Fahrenheit. The following option values may be configured -:
Value | Description |
---|---|
1 | Celsius |
9 | Fahrenheit |
The manufacturer defined default value is 9
(Fahrenheit).
This parameter has the configuration ID config_10_4_0000FF00
and is of type INTEGER
.
Upper/Lower bounds for thermostat temperature reporting The thermostat will report ambient temperature changes for temperature values less than the lower bound. This field must be between 0F and 124F. By default, this value is 124F (report all temperature changes). Values in the range 0 to 124 may be set.
The manufacturer defined default value is 124
.
This parameter has the configuration ID config_10_4_00FF0000
and is of type INTEGER
.
Simple mode enable/disable If the value is set to 0 then Normal Mode is enabled. If the value is set to 1 then Simple Mode is enabled. The following option values may be configured -:
Value | Description |
---|---|
0 | Normal mode enabled |
1 | Simple mode enabled |
The manufacturer defined default value is 1
(Simple mode enabled).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Enable or disables Multicast If set to 0, Multicast is disabled. If set to 1, Multicast is enabled. The following option values may be configured -:
Value | Description |
---|---|
0 | Multicast disabled |
1 | Multicast enabled |
The manufacturer defined default value is 0
(Multicast disabled).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The CT100 Plus supports 1 association group.
Send report about Thermostat Mode, Thermostat Operating State, Fan Mode, Fan State, Setpoint, Sensor Multilevel
Association group 1 supports 2 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_INDICATOR_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.