layout | title |
---|---|
documentation |
CT110 - ZWave |
{% include base.html %}
This describes the Z-Wave device CT110, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct110_00_000
.
The CT110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the CT110 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Sensor (relative humidity) | sensor_relhumidity | Humidity | Number |
Thermostat mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | Temperature | Number |
Setpoint (furnace) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (dry air) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | ||
Battery Level | battery-level | Battery | Number |
Clock Time Offset | time_offset | Temperature | Number |
Sensor (temperature) 1 | sensor_temperature1 | Temperature | Number:Temperature |
Sensor (relative humidity) 1 | sensor_relhumidity1 | Humidity | Number |
Thermostat mode 1 | thermostat_mode1 | Temperature | Number |
Operating State 1 | thermostat_state1 | Temperature | Number |
Setpoint (furnace) 1 | thermostat_setpoint1 | Temperature | Number:Temperature |
Setpoint (dry air) 1 | thermostat_setpoint1 | Temperature | Number:Temperature |
Setpoint (heating) 1 | thermostat_setpoint1 | Temperature | Number:Temperature |
Setpoint (cooling) 1 | thermostat_setpoint1 | Temperature | Number:Temperature |
Thermostat fan mode 1 | thermostat_fanmode1 | ||
Thermostat fan state 1 | thermostat_fanstate1 | ||
Battery Level | battery-level | Battery | Number |
Clock Time Offset 1 | time_offset1 | Temperature | Number |
Sensor (temperature) 2 | sensor_temperature2 | Temperature | Number:Temperature |
Sensor (relative humidity) 2 | sensor_relhumidity2 | Humidity | Number |
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
Indicates the current temperature.
The sensor_temperature1
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity1
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Sets the thermostat.
The thermostat_mode1
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state1
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint1
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel supports the Number:Temperature
item and is in the Temperature
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level1
channel supports the Number
item and is in the Battery
category.
Provides the current time difference for the devices time.
The time_offset1
channel supports the Number
item and is in the Temperature
category.
Indicates the current temperature.
The sensor_temperature2
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity2
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.