This describes the Z-Wave device CT80, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct80_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The CT80 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Push Menu button, choose network, choose Z-Wave Radio, push "Mate" (only usable with Z-Wave Module)
The following table summarises the channels available for the CT80 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Thermostat Mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | Temperature | Number |
Setpoint (cooling) | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | Heating | Number:Temperature |
Thermostat Fan Mode | thermostat_fanmode | ||
Battery Level | battery-level | Battery | Number |
Clock Time Offset | time_offset | Temperature | Number |
Sensor (relative humidity) | sensor_relhumidity1 | Humidity | Number |
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Heating
category.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity1
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 12 configuration parameters available in the CT80. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Temperature Reporting Threshold | Reporting threshold for changes in the ambient temperature. |
2 | HVAC Settings | Configured HVAC settings |
3 | Utility Lock Enable/Disable | Prevents setpoint changes at thermostat. |
4 | Power Status | C-Wire / Battery Status |
5 | Humidity Reporting Threshold | Reporting threshold for changes in the relative humidity. |
6 | Auxiliary/Emergency | Enables or disables auxiliary / emergency heating |
7 | Thermostat Swing Temperature | Variance allowed from setpoint to engage HVAC |
8 | Thermostat Diff Temperature | Configures additional stages |
9 | Thermostat Recovery Mode | Fast or Economy recovery mode. |
10 | Temp Reporting Filter | Upper/Lower bounds for thermostat temperature reporting |
11 | Simple UI Mode | Simple Mode Enable/Disable |
12 | Multicast | Enable or disables Multicast |
Reporting threshold for changes in the ambient temperature. This value determines the reporting threshold when association reporting is enabled. Unsupported values will be ignored. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | 0.5° |
2 | 1.0° |
3 | 1.5° |
4 | 2.0° |
The manufacturer defined default value is 2
(1.0°).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Configured HVAC settings Byte 1 = HVAC Setup: Normal (0x01) or Heat Pump (0x02)
Byte 2 = Aux Setup(Gas (0x01) or Electric (0x02)) & Number of Auxiliary Stages (Heat Pump)/Number of Heat Stages (Normal)
Byte 3 = Number of Heat Pump Stages
Byte 4 = Number of Cool Stages Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_4
and is of type INTEGER
.
This is a read only parameter.
Prevents setpoint changes at thermostat. If set to 0, the utility lock is disabled, all other values, 1-255, will enable the utility lock. This will prevent changes to the setpoint at the thermostat screen. The following option values may be configured -:
Value | Description |
---|---|
0 | Utility lock disabled |
1 | Utility lock enabled |
The manufacturer defined default value is 0
(Utility lock disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
C-Wire / Battery Status If 0x01, the thermostat is being powered from a C-wire, if 0x02, the thermostat is being powered off of batteries. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
This is a read only parameter.
Reporting threshold for changes in the relative humidity. This value determines the reporting threshold when association reporting is enabled. Unsupported values will be ignored. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | 3% RH |
2 | 5% RH |
3 | 10%RH |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Enables or disables auxiliary / emergency heating If set to 0, auxiliary / emergency heat is disabled, all other values, 1-255, will enable the auxiliary / emergency heat. This can only be enabled when the thermostat is set to Heat Pump mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Auxiliary/Emergency heat disabled |
1 | Auxiliary/Emergency heat enable |
The manufacturer defined default value is 0
(Auxiliary/Emergency heat disabled).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Variance allowed from setpoint to engage HVAC The thermostat swing temperature is in units of 0.5 degrees Fahrenheit. A value of 0x01 is 0.05F and 0x02 is 1.0F. The supported values may vary from thermostat to thermostat but typically the allowed values are 0.5F (0x01) to 4.0F (0x08).
The Thermostat Swing Temperature configuration command sets swing temperature on the thermostat. The swing temperature is applied to the setpoint to determine when the thermostat will turn on the HVAC system. If the thermostat is heating, the swing temper The following option values may be configured -:
Value | Description |
---|---|
1 | 0.5° |
2 | 1.0° |
3 | 1.5° |
4 | 2.0° |
5 | 2.5° |
6 | 3.0° |
7 | 3.5° |
8 | 4.0° |
The manufacturer defined default value is 2
(1.0°).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Configures additional stages Sets the differential temperature for multi-stage HVAC systems. The differential temperature delta defines when the thermostat will turn on additional stages. This command configures both the heat and cool differential temperatures.
See the RTZW-02 manual for command definition. The following option values may be configured -:
Value | Description |
---|---|
4 | 2.0 F |
8 | 4.0 F |
12 | 6.0 F |
The manufacturer defined default value is 4
(2.0 F).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Fast or Economy recovery mode. The Thermostat Recovery Mode can be either fast (0x01) or economy (0x02). Values in the range 1 to 2 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Upper/Lower bounds for thermostat temperature reporting Sets the upper/lower bounds for the thermostat reporting ambient temperature changes. The value must be between 0F and 124F. By default the value is set to 0F (report all changes). Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Simple Mode Enable/Disable If the value is set to 0x00 then Normal Mode is enabled. If the value is set to 0x01 then Simple Mode is enabled. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Enable or disables Multicast If set to 0, multicast is disabled, if set to 1, will enable the multicast. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The CT80 supports 1 association group.
This device support one association group, and up to two nodes in that group. If at least one node is added to association group one (1), the thermostat will send the following association reports when the respective state has changed:
• Thermostat Mode Report
• Thermostat Operating State Report
• Fan Mode Report
• Fan State Report
• Setpoint Report (for all supported setpoints)
• Sensor Multilevel Report (if enabled by Configuration Command Class)
The association command class can be configured to send encapsulated reports via the Multi Instance Command Class or the Multi Channel Command Class. If the association configuration commands are sent inside encapsulated commands, the thermostat will respond with encapsulated reports of the same type (Multi Instance v1 or Multi Channel v3). Encapsulation is the only way to configure the thermostat to send humidity sensor multilevel association reports.
For example, if an Association Set is encapsulated in a Multi Channel Command Encapsulation command is sent to the humidity instance (2), then the thermostat will encapsulate all un-solicited humidity sensor multilevel reports in the Multi Channel Command Encapsulation Command. The default instance is the temperature instance (1). If the Association Set is sent un-encapsulated then the thermostat will send all un-solicited temperature sensor multilevel reports unencapsulated.
All association reports other than the humidity multilevel are in the default instance (1). The thermostat will encapsulate the association reports based on the last Association Set encapsulation type received (i.e. un-encapsulated, Multi Instance v1, or Multi Channel V3).
Association group 1 supports 2 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 |