This describes the Z-Wave device Motion Sensor, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_motionsensor_00_000
.
The device is in the category of Motion Detector, defining Motion sensors/detectors.
The Motion Sensor supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The Motion Sensor does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
In the Back casing, there is a button that is used to carry out include, exclude, wakeup device or reset factory default settings.
When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has not been added a Z‐Wave network. Please get familiar with the terms below before starting the operations.
- Remove the sensor cover.
- Make sure the sensor is powered.
- Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)
- Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times..
- Remove the device cover.
- Make sure the sensor is powered.
- Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual)
- Press the button three times within 1.5 second, the device will enter exclusion mode.
The Motion Sensor does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time. The minimum wakeup interval is 300s, the maximum wakeup interval is 16,777,200s (about 194 days). Allowable interval among each wakeup interval is 60 second, such as 360, 420, 480…
Note: The default value is 12 hours. This value is longer, the battery life is greater.
The following table summarises the channels available for the Motion Sensor -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Luminance Sensor | sensor_luminance | Number | |
Temperature Sensor | sensor_temperature | Temperature | Number:Temperature |
Motion Alarm | alarm_motion | Door | Switch |
Battery Level | battery-level | Battery | Number |
Indicates the current light reading.
The sensor_luminance
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates if a motion alarm is triggered.
The alarm_motion
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 11 configuration parameters available in the Motion Sensor. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Sensitivity Level Setting | Defines the sensitivity of PIR sensor. |
2 | ON/OFF Duration Setting | Determined how long the associated devices should stay ON status |
3 | Basic Set Level | Basic Set Command will be sent when the door/window is opened or closed |
4 | Enable/Disable PIR Function | |
5 | Lux Level Set | Set a lux level value which determines when the light sensor is activated. |
6 | Re-trigger Interval | Adjust the interval of PIR being re-triggered |
7 | Light Sensor Polling Interval | The Intervall after which the Light Sensor Measure is polled. |
8 | Lux Level Function Enable | 0 = Off, 1 =On |
9 | Lux Level Changed Report | How much the Lux Level must change |
10 | LED Blink Enable | Defines whether the LED blinking is on / off |
99 | Ambient light intensity calibration | Define the calibrated scale for ambient light intensity |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Defines the sensitivity of PIR sensor. Where 8 = highest & 255 = lowest sensitivity Values in the range 8 to 255 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Determined how long the associated devices should stay ON status For instance, this parameter is set to 30(second), the PIR detector will send a BASIC SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off. This Parameter value must be large than Parameter #6. Values in the range 5 to 600 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Basic Set Command will be sent when the door/window is opened or closed The receiver will take in for consideration; for instance, if a lamp module received the BSC of which value is decisive as to how bright of dim level of lamp module shall be.
Available Settings:
- 0 - Off, Alarm cancelling or turning a device OFF
- 1~99 or 255 – ON (Binary Switch Device)
- Dim Level (Multilevel Switch Device) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable PIR Detector Function |
255 | Enable PIR Detector Function |
The manufacturer defined default value is 255
(Enable PIR Detector Function).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Set a lux level value which determines when the light sensor is activated. If the ambient illumination level falls below this value and a person moves across or within the detected area , PIR detector will send a Z-Wave ON command(i.e. BASIC_SET value = parameter 3#) to an associated device and activate it. Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Adjust the interval of PIR being re-triggered No report will be sent during this interval if a movement is presented. This Parameter value must be less than Parameter 2#. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
The Intervall after which the Light Sensor Measure is polled.
Values in the range 60 to 36000 may be set.
The manufacturer defined default value is 180
.
This parameter has the configuration ID config_7_2
and is of type INTEGER
.
0 = Off, 1 =On If this parameter is set to ‘1’, and when Lux level less than the value define by parameter #5, PIR detector will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it. If Lux Level greater than the value define by parameter #5, PIR detector will not send a BASIC_SET command frame. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Lux Level Function |
1 | Enable Lux Level Function |
The manufacturer defined default value is 0
(Disable Lux Level Function).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
How much the Lux Level must change How much the Lux Level must change, in lux, to be reported to the main controller. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_9_2
and is of type INTEGER
.
Defines whether the LED blinking is on / off 1 = enable -> blink once when motion sensor detect movement, 0= disabled The following option values may be configured -:
Value | Description |
---|---|
0 | Disable LED blinking |
1 | Enable LED blinking |
The manufacturer defined default value is 1
(Enable LED blinking).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Define the calibrated scale for ambient light intensity This parameter defines the calibrated scale for ambient light intensity, to allow more or less granular light measurements Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 1000
.
This parameter has the configuration ID config_99_2
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The Motion Sensor supports 4 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Is assigned to the device status - OPEN/CLOSED. It enables the sensor to send reports and readings to Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered.
- NOTIFICATION_REPORT
- COMMAND_CLASS_SENSOR_BINARY_V2
- COMMAND_CLASS_SENSOR_MULTILEVEL_V7
- BATTERY_REPORT
- DEVICE_RESET_LOCALLY_NOTIFICATION
Association group 1 supports 1 node.
Sending Control Command to associated devices. This association group is configured through the advanced parameters no. 2, 3, 5 and 8 BASIC_SET
Association group 2 supports 4 nodes.
Send Notification to associated devices. NOTIFICATION_REPORT_V4
Association group 3 supports 4 nodes.
Send Notification to associated devices. SENSOR_BINARY_REPORT_V2
Association group 4 supports 4 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |