Motion Sensor IN - ZWave

{% include base.html %}

Motion Sensor IN Motion Sensor IN

This describes the Z-Wave device Motion Sensor IN, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_motionsensorin_00_000.

The Motion Sensor IN supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The Motion Sensor IN does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Wakeup Information

The Motion Sensor IN does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the Motion Sensor IN -:

Channel Channel Id Category Item Type
Binary Sensor sensor_binary Door Switch
Sensor (luminance) sensor_luminance Number
Alarm (general) alarm_general Door Switch
Alarm (burglar) alarm_burglar Door Switch
Battery Level battery-level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Alarm (general)

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2