layout | title |
---|---|
documentation |
NAS-AB01Z - ZWave |
{% include base.html %}
This describes the Z-Wave device NAS-AB01Z, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_nasab01z_00_000
.
The device is in the category of Siren, defining Siren used by Alarm systems.
The NAS-AB01Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Siren Alarm with ten different sounds.
The siren alarm can be included to the Z-wave network by pressing on the code button.
- Disassemble the siren alarm and insert the battery into the siren alarm. Make sure the device is located within the direct range of the controller.
- Set the controller into the learning mode (see main controller’s operating manual).
- Quickly, triple click the code button, LED light will flash red.
- Siren alarm will be detected and included in the Z-Wave network.
- Wait for the main controller to configure the siren alarm.
- Make sure the sensor is connected to power source.
- Set the main controller into the learning mode (see main controller’s operating manual).
- Quickly, triple click the code button, LED light will flash red for 5 times.
- Wait for the main controller to delete the sensor.
The following table summarises the channels available for the NAS-AB01Z -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Siren ON Mode | config_decimal | Number | |
Alarm | alarm_general | Door | Switch |
Battery Level | battery-level | Battery | Number |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Configure default siren ON mode:
1 = Alarm Music Mode
2 = Door Bell Music
Generic class for configuration parameter.
The config_decimal
channel supports the Number
item.
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 7 configuration parameters available in the NAS-AB01Z. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Configure Alarm music volume | Configure Alarm music volume |
2 | Alarm music duration time | Alarm music duration time |
3 | Door bell music duration time | Door bell music duration time |
4 | Door bell music volume | Door bell music volume |
5 | Alarm music index | Alarm music index |
6 | Door bell music index | Door bell music index |
7 | Default Siren on mode | Default Siren on mode |
Configure Alarm music volume
Values in the range 1 to 3 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Alarm music duration time
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Door bell music duration time
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Door bell music volume
Values in the range 1 to 3 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Alarm music index
Values in the range 1 to 10 may be set.
The manufacturer defined default value is 9
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Door bell music index
Values in the range 1 to 10 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Default Siren on mode This parameter defines the default music index, volume and duration time for siren on.
This parameter can be selected between ALARM MUSIC and DOOR BELL music.
The settings for ALARM MUSIC defines by Param #1, #2, #5.
The settings for DOOR BELL defines by Param #3, #4, #6. Values in the range 1 to 2 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The NAS-AB01Z supports 3 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.