layout | title |
---|---|
documentation |
10002080-13x - ZWave |
{% include base.html %}
This describes the Z-Wave device 10002080-13x, manufactured by SimonTech S.L.U with the thing type UID of simontech_1000203413x_00_000
.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The 10002080-13x supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position.
When the pushbutton is released after a press of (2<T<10sec) the device will send a NIF to include from Z-Wave network or perform an association with other Z-Wave device.
Central LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
This process does not perform a default reset of configurations.
Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
When the pushbutton is released after a press of (2<T<10sec) the device will send a NIF to exclude from Z-Wave network or perform an association with other Z-Wave device.
Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
This process does not perform a default reset of configurations.
Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
The following table summarises the channels available for the 10002080-13x -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 9 configuration parameters available in the 10002080-13x. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Association LED | Activates the Central LED. |
4 | Up Time | Up Time |
5 | Down Time | Down Time |
9 | Calibration | Calibration |
12 | Behavior of LED in Repose | Configuration of Main LED as identification at 20%. |
13 | Lock Input | Unlock/lock the direct control of load. |
21 | Load State | Load State (Read Only) |
23 | Calibration Required | Calibration Required (Read Only) |
27 | Lock long press | 7 Lock long press |
Activates the Central LED.
The following option values may be configured -:
Value | Description |
---|---|
0 | Turns the LED OFF (default) |
255 | Turns the LED ON |
The manufacturer defined default value is 0
(Turns the LED OFF (default)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Up Time
The following option values may be configured -:
Value | Description |
---|---|
1 | Sets the UP time in seconds |
60 | Default |
The manufacturer defined default value is 60
(Default).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
This is a read only parameter.
Down Time
The following option values may be configured -:
Value | Description |
---|---|
1 | Sets the DOWN time in seconds |
60 | Default |
The manufacturer defined default value is 60
(Default).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Calibration 255 - The device will perform a calibration process in order to Set the UP and DOWN times automatically Values in the range 255 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_9_1_wo
and is of type INTEGER
.
This is a write only parameter.
Configuration of Main LED as identification at 20%.
The following option values may be configured -:
Value | Description |
---|---|
0 | LED OFF |
255 | LED ON at 20% of maximum level |
The manufacturer defined default value is 0
(LED OFF).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Unlock/lock the direct control of load.
The following option values may be configured -:
Value | Description |
---|---|
0 | Unlock the direct control of load. |
255 | Lock the direct control of load. |
The manufacturer defined default value is 0
( Unlock the direct control of load.).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Load State (Read Only)
The following option values may be configured -:
Value | Description |
---|---|
0 | Bit 0: Load is OFF |
0 | Bit 1: Sunblind position 0% |
1 | Bit 0: Load is going UP/DOWN |
99 | Bit 1: Sunblind position 99% |
The manufacturer defined default value is 0
(Bit 1: Sunblind position 0%).
This parameter has the configuration ID config_21_2
and is of type INTEGER
.
This is a read only parameter.
Calibration Required (Read Only)
The following option values may be configured -:
Value | Description |
---|---|
0 | Calibration is not required. |
255 | It is necessary to calibrate the device. |
The manufacturer defined default value is 0
(Calibration is not required.).
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
This is a read only parameter.
7 Lock long press
The following option values may be configured -:
Value | Description |
---|---|
0 | Long press works as default. |
255 | Long press works as overview. |
The manufacturer defined default value is 0
(Long press works as default.).
This parameter has the configuration ID config_27_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 10002080-13x supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline Change on Sunblind position:
- On -> CC Basic, Basic Report.
- Value 0x01 - 0x63 Report sunblind position
Calibration requirement change. (If device needs to be calibrated and is Added into a ZWave network, it will report after receive an Association Set of life line).
- Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xF
- Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00
Association group 1 supports 3 nodes.
Control Change on Sunblind position:
- CC Basic, Basic Report.
- Value 0x00 - 0x63 Report sunblind position
Association group 2 supports 20 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.