10002080-13x Simon IO: Roller Blind

This describes the Z-Wave device 10002080-13x, manufactured by SimonTech S.L.U with the thing type UID of simontech_1000203413x_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

10002080-13x product image

The 10002080-13x supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position.

Inclusion Information

When the pushbutton is released after a press of (2<T<10sec) the device will send a NIF to include from Z-Wave network or perform an association with other Z-Wave device.

Central LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.

This process does not perform a default reset of configurations.

Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.

Exclusion Information

When the pushbutton is released after a press of (2<T<10sec) the device will send a NIF to exclude from Z-Wave network or perform an association with other Z-Wave device.

Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.

This process does not perform a default reset of configurations.

Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.

Channels

The following table summarises the channels available for the 10002080-13x -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the 10002080-13x. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Association LED Activates the Central LED.
4 Up Time Up Time
5 Down Time Down Time
9 Calibration Calibration
12 Behavior of LED in Repose Configuration of Main LED as identification at 20%.
13 Lock Input Unlock/lock the direct control of load.
21 Load State Load State (Read Only)
23 Calibration Required Calibration Required (Read Only)
27 Lock long press 7 Lock long press

Parameter 1: Association LED

Activates the Central LED.

The following option values may be configured -:

Value Description
0 Turns the LED OFF (default)
255 Turns the LED ON

The manufacturer defined default value is 0 (Turns the LED OFF (default)).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 4: Up Time

Up Time

The following option values may be configured -:

Value Description
1 Sets the UP time in seconds
60 Default

The manufacturer defined default value is 60 (Default).

This parameter has the configuration ID config_4_1 and is of type INTEGER. This is a read only parameter.

Parameter 5: Down Time

Down Time

The following option values may be configured -:

Value Description
1 Sets the DOWN time in seconds
60 Default

The manufacturer defined default value is 60 (Default).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 9: Calibration

Calibration 255 - The device will perform a calibration process in order to Set the UP and DOWN times automatically Values in the range 255 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_9_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 12: Behavior of LED in Repose

Configuration of Main LED as identification at 20%.

The following option values may be configured -:

Value Description
0 LED OFF
255 LED ON at 20% of maximum level

The manufacturer defined default value is 0 (LED OFF).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Lock Input

Unlock/lock the direct control of load.

The following option values may be configured -:

Value Description
0 Unlock the direct control of load.
255 Lock the direct control of load.

The manufacturer defined default value is 0 ( Unlock the direct control of load.).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 21: Load State

Load State (Read Only)

The following option values may be configured -:

Value Description
0 Bit 0: Load is OFF
0 Bit 1: Sunblind position 0%
1 Bit 0: Load is going UP/DOWN
99 Bit 1: Sunblind position 99%

The manufacturer defined default value is 0 (Bit 1: Sunblind position 0%).

This parameter has the configuration ID config_21_2 and is of type INTEGER. This is a read only parameter.

Parameter 23: Calibration Required

Calibration Required (Read Only)

The following option values may be configured -:

Value Description
0 Calibration is not required.
255 It is necessary to calibrate the device.

The manufacturer defined default value is 0 (Calibration is not required.).

This parameter has the configuration ID config_23_1 and is of type INTEGER. This is a read only parameter.

Parameter 27: Lock long press

7 Lock long press

The following option values may be configured -:

Value Description
0 Long press works as default.
255 Long press works as overview.

The manufacturer defined default value is 0 (Long press works as default.).

This parameter has the configuration ID config_27_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 10002080-13x supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline Change on Sunblind position:

  • On -> CC Basic, Basic Report.
  • Value 0x01 - 0x63 Report sunblind position

Calibration requirement change. (If device needs to be calibrated and is Added into a ZWave network, it will report after receive an Association Set of life line).

  • Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xF
  • Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00

Association group 1 supports 3 nodes.

Group 2: ctrl

Control Change on Sunblind position:

  • CC Basic, Basic Report.
  • Value 0x00 - 0x63 Report sunblind position

Association group 2 supports 20 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2