Skip to content

Latest commit

 

History

History
279 lines (164 loc) · 9.97 KB

zv9102facct_0_0.md

File metadata and controls

279 lines (164 loc) · 9.97 KB
layout title
documentation
ZV9102FA-CCT - ZWave

{% include base.html %}

ZV9102FA-CCT Z-wave CCT LED controller

This describes the Z-Wave device ZV9102FA-CCT, manufactured by Sunricher with the thing type UID of sunricher_zv9102facct_00_000.

The device is in the category of Light Bulb, defining Devices that illuminate something, such as bulbs, etc..

ZV9102FA-CCT product image

The ZV9102FA-CCT supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The SR-ZV9102FA-CCT is a dual color zwave lighting device and z wave slave that adopts z-wave RF Plus and z-wave mesh network technology with 4 channel, 5A per channel output for dual color LED lights. As a z-wave slave, the device can be added to z-wave network or removed from z-wave network by z-wave primary (master) controllers or gateway. The z wave devices are transceivers that enable to receive and transmit RF signal from the z wave remote while both of them are added to the network. The transceiver is a universal z wave slave which is compatible with universal z wave primary (master) controllers/gateway.

Inclusion Information

Power on the receiver. By factory default setting, the connected LED lights will be under a slow rhythm breath status which means the receiver is waiting to be searched by the master (primary) controller or z-wave gateway -> set the z-wave master (primary) controller or gateway into network inclusion mode (please refer to the user manual to learn how)

There shall be an indication on the master (primary) controller or gateway -> LED light connected with the receiver flashes 5 times quickly to indicate successful and automatic adding to z-wave network

Exclusion Information

When the receiver has already been added to z-wave network and connected LED light is switched on, set the z-wave master (primary) controller or gateway into network exclusion mode (please refer to the user manual to learn how).

Click the “prog” key on the receiver -> there shall be an indication on the master (primary) controller -> the connected LED light with the receiver flashes twice to indicate successful removal from z-wave network

Channels

The following table summarises the channels available for the ZV9102FA-CCT -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number Number
Color Control color_color Color
Color Temperature color_temperature ColorLight Dimmer
Alarm (system) alarm_system Switch

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Color Control

The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off.

The color_color channel supports the Color item.

Color Temperature

The color temperature channel allows to set the color temperature of a light from 0 (cold) to 100 (warm).

The color_temperature channel supports the Dimmer item and is in the ColorLight category.

Alarm (system)

Indicates if a system alarm is triggered.

The alarm_system channel supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the ZV9102FA-CCT. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Save state on power failure Shut off load (default), turn on load or restore saved state after power failure
3 Enable/disable BASIC report Enable/disable sending of BASIC reports
4 Colour channels Set number of channels of LED load - single colour, CCT or RGBW
5 Stage mode Set stage mode for lighting changes
6 Stage mode speed Set speed of changes in stage mode
7 Stage mode execution time Set execution time for stage mode
8 Stage mode hue Set stage mode hue 0-255
9 Set external switch function Enable / disable external switch for inclusion / exclusion

Parameter 2: Save state on power failure

Shut off load (default), turn on load or restore saved state after power failure Load state after power failure

0 - (default) shut off load

1 - turn on load

2 - restore saved state after power failure Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Enable/disable BASIC report

Enable/disable sending of BASIC reports Enable or disable sending of BASIC reports

0 - Disable sending of BASIC reports

1 - (default) Enable sending of BASIC reports Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Colour channels

Set number of channels of LED load - single colour, CCT or RGBW Set number of channels of LED load

0 - single colour - 4 channel PWM output to drive 4 channels of single colour LEDs

1 - CCT - 2 channel PWM output to drive CCT LEDs R/B control warm white, G/W control cool white

2 - (default) RGBW - single channel PWM output to control RGBW LEDs Values in the range 0 to 2 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Stage mode

Set stage mode for lighting changes Set lighting stage mode

0 - (Default) - no stage mode

1 - flash mode, colors set by parameter 8

2 - rainbow mode, system fixed changing effect

4 - fade in and fade out mode, color changes randomly

5 - flash mode, color changes randomly

6 - rainbow mode, color changes randomly

7 - random mode, the colors switch randomly Values in the range 0 to 7 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Stage mode speed

Set speed of changes in stage mode Set speed of stage mode 0-255

0 is slowest 255 is fastest Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Stage mode execution time

Set execution time for stage mode Set execution time for stage mode

0 (default) - unlimited time

1 - 255 set execution time Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Stage mode hue

Set stage mode hue 0-255 Set hue for stage mode

0 - 255 (default)

Only valid for fade in, fade out and flash mode. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Set external switch function

Enable / disable external switch for inclusion / exclusion Enable / disable external switch for inclusion / excluison of the device to / from the network

0 - (default) disable switch

1 - enable switch Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZV9102FA-CCT supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Single Cast DEVICE_RESET_LOCALLY_NOTIFICATION (sent when factory reset the device)

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SWITCH_COLOR_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.