This describes the Z-Wave device TZ06, manufactured by TKB Home with the thing type UID of tkb_tz06_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The TZ06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This in-wall switch module is a transceiver which is a Z-Wave Plus™ enabled device and is fully compatible with any Z-Wave enabled network.
Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration.
There are many kind of application by using the module to switch Load On and Off, one main application is the light control.
In the front casing, there is an on/off button with LED indicator below which is to toggle switch on and off or carries out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Pressing the Include button of TZ06 three times within 2 seconds will enter inclusion mode
Pressing the Include button of TZ06 three times within 2 seconds will enter exclusion mode
The following table summarises the channels available for the TZ06 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Alarm | alarm_general | Door | Switch |
Switch 1 | switch_binary1 | Switch | Switch |
Switch 2 | switch_binary2 | Switch | Switch |
Switch 3 | switch_binary3 | Switch | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
Switch the power on and off.
The switch_binary2
channel supports the Switch
item and is in the Switch
category.
Switch the power on and off.
The switch_binary3
channel supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 6 configuration parameters available in the TZ06. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Selected Relay | Selected Relay (Endpoint) |
2 | External Switch Mode | Change the External Switch (S1 & S2) Mode |
3 | Restore Switch State | Restore Switch State after AC power loss |
4 | Auto OFF Timer | Auto OFF Timer Countdown |
5 | RF Command Mode | RF Command Mode |
6 | Existence of Endpoint 3 | Existence of Endpoint 3 |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Selected Relay (Endpoint) If Controller not using Multi_Channel command class to access the endpoint of PAN06, you may configure the endpoint value to react the Basic Command Class
Relay 1: Only Relay 1 can be controlled and configured
Relay 2: Only Relay 2 can be controlled and configured
Relay 1 & 2: Both Relays can be controlled and configured
The following option values may be configured -:
Value | Description |
---|---|
1 | Relay 1 |
2 | Relay 2 |
3 | Relay 1&2 |
The manufacturer defined default value is 3
(Relay 1&2).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Change the External Switch (S1 & S2) Mode Manual Switch S1 and S2 can be set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode. The following option values may be configured -:
Value | Description |
---|---|
1 | Edge mode |
2 | Pulse mode |
3 | Edge-Toggle mode |
The manufacturer defined default value is 1
(Edge mode).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Restore Switch State after AC power loss Whenever the AC Power return from lost, TZ06 will restore the Switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch OFF |
1 | Last Switch State |
2 | Switch ON |
The manufacturer defined default value is 1
(Last Switch State).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Auto OFF Timer Countdown Whenever TZ06 switches to ON, the auto OFF timer will begin to count down. After the time decreases to zero, it will switch to OFF automatically. However, if auto OFF timer is set to 0, the auto OFF function will be disabled. The default setting is 0. Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
RF Command Mode Whenever a Switch OFF command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands.
5-0: Switch OFF: It switches to OFF State. The default setting is Switch OFF
5-1: Ignore: The Switch OFF command will be ignored
5-2: Switch Toggle: It switches to the inverse of current State
5-3: Switch ON: It switches to ON state
The following option values may be configured -:
Value | Description |
---|---|
0 | Switch OFF |
1 | Switch Ingore |
2 | Switch Toggle |
3 | Switch ON |
The manufacturer defined default value is 0
(Switch OFF).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Existence of Endpoint 3 The Endpoint 3 of Multi-Channel Command Class is related to Relay 1 and Relay 2.
It may be redundant for the need to control Relay 1 or Relay 2 individually. When the existence of Endpoint 3 is set as 2, the endpoint 3 of Multi-Channel Command Class will be disabled. The default value is 1. The following option values may be configured -:
Value | Description |
---|---|
1 | Endpoint 3 exists |
2 | No Endpoint 3 |
The manufacturer defined default value is 1
(Endpoint 3 exists).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TZ06 supports 3 association groups.
Association group 1 supports 1 node.
Association group 2 supports 1 node.
Association group 3 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_PULSE_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_LANGUAGE_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.