This describes the Z-Wave device TZ55D, manufactured by TKB Home with the thing type UID of tkb_tz55d_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The TZ55D supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Dual Paddle Wall Dimmer, AC230V 50Hz, 1380W×2
Pressing On/Off button three times within 1.5 seconds will enter inclusion mode.
Pressing On/Off button three times within 1.5 seconds will enter exclusion mode.
The following table summarises the channels available for the TZ55D -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Paddle 1 | switch_dimmer | DimmableLight | Dimmer |
Paddle 2 | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
The following table provides a summary of the 5 configuration parameters available in the TZ55D. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Night Light | LED Mode |
2 | Memory Function | Switch memory function |
3 | Invert Switch | Reverse switch direction |
4 | LED Transmission Indication | Set LED flickering mode |
5 | Suspend Group 4 | Disable transmitting commands to devices that are in Group 4 |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
LED Mode The LED on the switch will by default, turn ON when the load attached is turn OFF. To make the LED turn ON when the load attached is turn ON instead, set parameter 1 to a value of 1. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Switch memory function Stated in the above form, switch by default value is 1, when the value is 0, switch memory function not open; when the value is 1, open switch memory function. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Reverse switch direction
To change the top of the switch to OFF and the bottom of the switch ON, set parameter 3 to 1.
Note: if you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch.
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set LED flickering mode
The switch will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 2), or to flicker for only 1 second when it begins transmitting (set to 1).
By default, the switch is set to flicker for only 1 second.
Values in the range 0 to 2 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Disable transmitting commands to devices that are in Group 4 You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “disassociating” those devices from from the group. Setting parameter 5 to the value of 1 will stop the switch from transmitting to devices that are “associated” into Group 4. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TZ55D supports 4 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Group 1 Control If you associate a Z-Wave device into Group 1, you can turn that device ON and OFF by tapping the top or bottom of the right switch, you can brighten or dim devices by pushing and holding the top of the right switch Dim by pushing and holding the bottom of the right switch.
The load attached to the switch is not affected.
The LED on the right switch will indicate the status of Group 1. Group 1 will be polled at a specific interval and the LED on the right switch will indicate the status of Group 1. The polling interval can be configured. The Group1 name is lifeline(Profile MSB=0x00,Profile LSB=0x01)
Association group 1 supports 5 nodes.
Group 2 Control Group 2 Control: If you associate a Z-Wave device into Group 2, you can turn that device ON or OFF by tapping the top or bottom of the left switch twice. You can brighten or dim devices by tapping the switch once then push and hold the top or bottom of the left switch.
The load attached to the switch is not affected.
The LED on the left switch will indicate the status of Group 2. Group 2 will be polled at a specific interval and the LED on the left switch will indicate the status of Group 2. The polling interval can be configured. The Group2 name is On/Off Dimmer 1(Profile MSB=0x20,Profile LSB=0x01).
Association group 2 supports 5 nodes.
Group 3 Control Group 3 Control: If you associate a Z-Wave device into Group 3, you can turn that device ON or OFF by tapping the top or bottom of the righ switch twice. You can brighten or dim devices by tapping the switch once then push and hold the top or bottom of the righ switch.
The load attached to the switch is not affected.
The Group3 name is on off dimmer 2 (Profile MSB=0x20,Profile LSB=0x02).
Association group 3 supports 5 nodes.
Group 4 Control Group 4 Control: If you associate a Z-Wave device into Group 4, that device will be commanded to turn on or off when the switch is commanded to turn on or off Caution: The switch will not transmit to Z-Wave devices in Group 4 if it is already in the state that the Z-Wave command commanded it to.
The Group4 name is wireless.(Profile MSB=0x20, Profile LSB=0x03)
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |