layout | title |
---|---|
documentation |
AZEMT500BB32MA - ZWave |
{% include base.html %}
This describes the Z-Wave device AZEMT500BB32MA, manufactured by Trane Corporation with the thing type UID of trane_azemt500bb32ma_00_000
.
The AZEMT500BB32MA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the AZEMT500BB32MA -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Scene Number | scene_number | Number | |
Sensor (relative humidity) | sensor_relhumidity | Humidity | Number |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | ||
Clock Time Offset | time_offset | Temperature | Number |
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
Indicates the current relative humidity.
The sensor_relhumidity
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
The following table provides a summary of the 1 configuration parameters available in the AZEMT500BB32MA. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
132 | Schedule Mode |
The following option values may be configured -:
Value | Description |
---|---|
0 | Hold |
1 | Schedule |
The manufacturer defined default value is 0
(Hold).
This parameter has the configuration ID config_132_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The AZEMT500BB32MA supports 1 association group.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.