Skip to content

Files

Latest commit

bec2c28 · Oct 21, 2018

History

History
143 lines (100 loc) · 4.51 KB

xr524_0_0.md

File metadata and controls

143 lines (100 loc) · 4.51 KB
layout title
documentation
Trane XR524 - ZWave

{% include base.html %}

Trane XR524 Touchscreen Comfort Control Thermostat

This describes the Z-Wave device Trane XR524, manufactured by Trane Corporation with the thing type UID of trane_xr524_00_000.

The Trane XR524 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the Trane XR524 -:

Channel Channel Id Category Item Type
Sensor (temperature) sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode Temperature Number
Operating State thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint Temperature Number:Temperature
Setpoint (cooling) thermostat_setpoint Temperature Number:Temperature
Thermostat fan mode thermostat_fanmode
Thermostat fan state thermostat_fanstate

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel supports the Number:Temperature item and is in the Temperature category.

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel supports the Number:Temperature item and is in the Temperature category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CMD_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.