DS100 Double Switch in a dual relay in-wall module.

This describes the Z-Wave device DS100, manufactured by Vemmio with the thing type UID of vemmio_ds100_00_000.

DS100 product image

The DS100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DS100 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Scene Number scene_number Number
Electric meter (power factor) meter_powerfactor Energy Number
Electric meter (volts) meter_voltage Energy Number
Electric meter (amps) meter_current Energy Number
Electric meter (watts) meter_watts Energy Number
Electric meter (kWh) meter_kwh Energy Number
Alarm alarm_general Door Switch
Switch 1 switch_binary1 Switch Switch
Electric meter (power factor) 1 meter_powerfactor1 Energy Number
Electric meter (volts) 1 meter_voltage1 Energy Number
Electric meter (amps) 1 meter_current1 Energy Number
Electric meter (watts) 1 meter_watts1 Energy Number
Electric meter (kWh) 1 meter_kwh1 Energy Number
Switch 2 switch_binary2 Switch Switch
Electric meter (power factor) 2 meter_powerfactor2 Energy Number
Electric meter (volts) 2 meter_voltage2 Energy Number
Electric meter (amps) 2 meter_current2 Energy Number
Electric meter (watts) 2 meter_watts2 Energy Number
Electric meter (kWh) 2 meter_kwh2 Energy Number
Switch 3 switch_binary3 Switch Switch
Electric meter (power factor) 3 meter_powerfactor3 Energy Number
Electric meter (volts) 3 meter_voltage3 Energy Number
Electric meter (amps) 3 meter_current3 Energy Number
Electric meter (watts) 3 meter_watts3 Energy Number
Electric meter (kWh) 3 meter_kwh3 Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Electric meter (power factor) 1

Indicates the instantaneous power factor.

The meter_powerfactor1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 1

Indicates the instantaneous voltage.

The meter_voltage1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 1

Indicates the instantaneous current consumption.

The meter_current1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Electric meter (power factor) 2

Indicates the instantaneous power factor.

The meter_powerfactor2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 2

Indicates the instantaneous voltage.

The meter_voltage2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 2

Indicates the instantaneous current consumption.

The meter_current2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 3

Switch the power on and off.

The switch_binary3 channel supports the Switch item and is in the Switch category.

Electric meter (power factor) 3

Indicates the instantaneous power factor.

The meter_powerfactor3 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 3

Indicates the instantaneous voltage.

The meter_voltage3 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 3

Indicates the instantaneous current consumption.

The meter_current3 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 3

Indicates the instantaneous power consumption.

The meter_watts3 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 3

Indicates the energy consumption (kWh).

The meter_kwh3 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the DS100. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Watt Meter Report Period 720*5s=3600s=1hour
2 KWH Meter Report Period 6*10 min = 1 hour
3 Selected Relay 1: Relay 1, 2: Relay 2, 3: Relay 1 & Relay 2
4 Edge or Pulse mode or Edge-Toggle mode 1: Edge mode, 2: Pulse mode, 3: Edge-Toggle mode
5 Threshold of current for load caution 750*0.01A=7.5A
6 Threshold of KWH for load caution
7 Restore switch state mode 0: Switch off, 1: Last switch, 2: Switch on
8 Auto off timer 0: Disable auto off function, 1: 0x0-0x7FFF 1s-32767s
9 RF off command mode 0: Switch off, 1: Ignore, 2: Switch toggle, 3: Switch on
10 Existence of endpoint 3 1: endpoint 3 exists, 2: No endpoint 3
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 0: Watt Meter Report Period

720*5s=3600s=1hour

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_0_2 and is of type INTEGER.

Parameter 2: KWH Meter Report Period

6*10 min = 1 hour

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Selected Relay

1: Relay 1, 2: Relay 2, 3: Relay 1 & Relay 2

Values in the range 1 to 3 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Edge or Pulse mode or Edge-Toggle mode

1: Edge mode, 2: Pulse mode, 3: Edge-Toggle mode

Values in the range 1 to 3 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Threshold of current for load caution

750*0.01A=7.5A

Values in the range 10 to 750 may be set.

The manufacturer defined default value is 750.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Threshold of KWH for load caution

Values in the range 1 to 10000 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Restore switch state mode

0: Switch off, 1: Last switch, 2: Switch on

Values in the range 0 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Auto off timer

0: Disable auto off function, 1: 0x0-0x7FFF 1s-32767s

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: RF off command mode

0: Switch off, 1: Ignore, 2: Switch toggle, 3: Switch on

Values in the range 0 to 3 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Existence of endpoint 3

1: endpoint 3 exists, 2: No endpoint 3

Values in the range 1 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3

Documentation Links