layout | title |
---|---|
documentation |
ZM1601 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZM1601, manufactured by Vision Security with the thing type UID of vision_zm1601_00_000
.
The device is in the category of Siren, defining Siren used by Alarm systems.
The ZM1601 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the ZM1601 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Alarm (general) | alarm_general | Door | Switch |
Alarm (burglar) | alarm_burglar | Door | Switch |
Battery Level | battery-level | Battery | Number |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 2 configuration parameters available in the ZM1601. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Siren Strobe Mode | Defines the reaction of the siren |
2 | Alarm auto stop | Defines the auto time out of the alarm indication |
Defines the reaction of the siren
The following option values may be configured -:
Value | Description |
---|---|
0 | All Enabled |
1 | Siren Only |
2 | Strobe Only |
The manufacturer defined default value is 0
(All Enabled).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Defines the auto time out of the alarm indication
The following option values may be configured -:
Value | Description |
---|---|
0 | 30 seconds |
1 | 60 seconds |
2 | 120 seconds |
3 | Continuous |
The manufacturer defined default value is 0
(30 seconds).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZM1601 supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.