This describes the Z-Wave device ZW4101, manufactured by Vision Security with the thing type UID of vision_zw4101_00_000
.
The ZW4101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Drapery controller, supports up/stop/down commands.
Devices is OEMed as Monoprice 11993.
The following table summarises the channels available for the ZW4101 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 3 configuration parameters available in the ZW4101. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Up output time | Up output time |
2 | Stop output time | Stop output time |
3 | Down output time | Down output time |
Up output time Time to hold the "up" output button closed (shorted) when unit receives an "up" z-wave command. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Stop output time Time to hold the "stop" output button closed (shorted) when unit receives a "stop" z-wave command.
Note that the unit will automatically execute STOP, UP or STOP, DOWN when receiving an up or down command. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Down output time Time to hold the "down" output button closed (shorted) when unit receives a "down" z-wave command. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_VERSION_V1 |