iShutter iShutter

This describes the Z-Wave device iShutter, manufactured by Wintop with the thing type UID of wintop_ishutter_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

iShutter product image

The iShutter supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the iShutter -:

Channel Channel Id Category Item Type
Switch 1 switch_binary Switch Switch
Switch 2 switch_binary1 Switch Switch
switch_binary2 Switch Switch

Switch 1

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the iShutter. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Buttons Mode See overview
2 Automatically close after If not zero, automatically close blind after a user defined time
3 What to do on RF close command Defines how to interpret RF Off command.
4 Typical click timeout time used to differentiate click, hold, double and triple clicks
5 Invert buttons Invert buttons
6 Action on button press or hold Defines which command should be sent to Association group
7 LED mode Set LED indication mode
10 Full close time Time to go from opened to closed state.
11 Full open time Time to go from closed to open state
12 Node Id of the blocking device Id of the device which commands would not be Open/Close, but as block/unblock.
13 which command from blocking node to enable the protection Which command from blocking device is closed door and hence, unprotected.
14 Invert open and close relays Allow exchanging open and close relays
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Buttons Mode

See overview 0 -> One push button

1 -> Two paddles with Power and Direction

2 -> Two toggle switch

3 -> Two buttons with neutral position 

One push button: One button is used (chose any), press while moving up and down, stops, while stopped moves to opposite direction to previous. Two buttons with neutral position: Up click moves up if stopped and stops if moving down, Down click moves down  The following option values may be configured -:

Value Description
0 One push button
1 Two paddles with Power and Direction
2 Two toggle switch
3 Two buttons with neutral position

The manufacturer defined default value is 0 (One push button).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Automatically close after

If not zero, automatically close blind after a user defined time

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: What to do on RF close command

Defines how to interpret RF Off command. 0 -> Close

1 -> Ignore

2 -> Open

3 -> Open if closed, otherwise Close

Can be used in conjunction with Auto Close function: Ignore - to open the door by motion detectors and close it back after some amount of time: in case of multiple motion detectors each would try to open that would that would break logics; Open - to open on both On and Off paddle press on the remote and close after some amount of time. Button close click will still work (if button operations are not disabled). Note that Dim Down command will still begin close motion.  The following option values may be configured -:

Value Description
0 Close
1 Ignore
2 Open
3 Open if closed, otherwise Close

The manufacturer defined default value is 0 (Close).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Typical click timeout

time used to differentiate click, hold, double and triple clicks 1 - 100 -> in 10ms units Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Invert buttons

Invert buttons 0 -> No

1 -> Yes  The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Action on button press or hold

Defines which command should be sent to Association group Defines which command should be sent to Association group on button press or hold. Scene mode will send 1 for Up event, 2 for Stop, 3 for Down.

1 -> Switch On, Off and dim using Basic Set and MultiLevel Start/Stop Changing

2 -> Send Scene  The following option values may be configured -:

Value Description
1 Switch On, Off and dim using Basic Set
2 Send Scene

The manufacturer defined default value is 1 (Switch On, Off and dim using Basic Set).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: LED mode

Set LED indication mode 0 -> Disabled

1 -> Show working state

2 -> Always on

3 -> Show opened state

4 -> Indicator Command Class The following option values may be configured -:

Value Description
0 Disabled
1 Show working state
2 Always on
3 Show opened state
4 Indicator Command Class

The manufacturer defined default value is 1 (Show working state).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 10: Full close time

Time to go from opened to closed state. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and  multilevel Set values (1-99, 255) would Open except 0 value that would Close.  Values in the range 0 to 255 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Full open time

Time to go from closed to open state Time to go from closed to open state. This value may differ from Full close time for some blinds due to gravity. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close Values in the range 0 to 255 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Node Id of the blocking device

Id of the device which commands would not be Open/Close, but as block/unblock. Id of the device which commands would be interpreted not as Open/Close, but as block/unblock. Usefull with door opening detector: if the door is open, block the blind not to break shades while they move. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: which command from blocking node to enable the protection

Which command from blocking device is closed door and hence, unprotected. 0 -> on On

1 -> on Off The following option values may be configured -:

Value Description
0 on On
1 on Off

The manufacturer defined default value is 0 (on On).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Invert open and close relays

Allow exchanging open and close relays Allow exchanging open and close relays if blind control is wired to the motor incorrectly 

0 -> No

1 -> Yes The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The iShutter supports 2 association groups.

Group 1: Click, press and hold of up/down buttons

Click, press and hold of up/down buttons

Association group 1 supports 10 nodes.

Group 2: Send Reports on blind state change

Send Reports on blind state change

Association group 2 supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_SWITCH_BINARY_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1

Documentation Links