layout | title |
---|---|
documentation |
SD-L1000-CH - ZWave |
{% include base.html %}
This describes the Z-Wave device SD-L1000-CH, manufactured by ASSA ABLOY with the thing type UID of yale_ycl1_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The SD-L1000-CH supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Open the door to your world with the Conexis(R) L1 Smart Door Lock. The Smart Door Lock that puts you fully in control giving you the freedom to secure your home without the need for a key.
Control access from your smartphone
Say goodbye to your keys
Control access from your smartphone
- Ensure the Z-Wave controller is close to the lock, around 1.5m.
- Remove the upper plastic cover from the lock, on the interior side.
- Set the controller into inclusion mode.
- Press the reset 'R' button 3 times in 1.5s (3 quick presses), the lock will beep twice.
- Upon connection, the lock will play 3 notes.
- Remove the upper plastic cover from the lock, on the interior side.
- Set the controller into exclusion mode.
- Press the reset 'R' button 3 times in 1.5s (3 quick presses), the lock will beep twice.
- Upon successful exclusion, the lock will play 3 notes.
The following table summarises the channels available for the SD-L1000-CH -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door Lock | lock_door | Door | Switch |
Alarm | alarm_general | Door | Switch |
Battery Level | battery-level | Battery | Number |
Clock Time Offset | time_offset | Temperature | Number |
Lock and unlock the door.
The lock_door
channel supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
The following table provides a summary of the 5 configuration parameters available in the SD-L1000-CH. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Volume | Beep volume |
2 | Auto Re-lock | The lock will re-lock automatically if untouched for the timeout |
3 | Re-lock time | The amount of time which the lock will wait before re-locking |
4 | Wrong tag limit | Number of wrong tags that can be tried before stand-down |
7 | Wrong tag timeout | Time after the wrong tag limit being exceeded before re-trying |
Lock Timeout | Sets the time after which the door will auto lock |
Beep volume 1 = Silent mode
2 = Low volume
3 = High volume (default) The following option values may be configured -:
Value | Description |
---|---|
1 | Silent |
2 | Low |
3 | High |
The manufacturer defined default value is 3
(High).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
The lock will re-lock automatically if untouched for the timeout 0 = No auto re-lock (default)
255 = auto re-lock The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
The amount of time which the lock will wait before re-locking Re-lock time in seconds Values in the range 7 to 60 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Number of wrong tags that can be tried before stand-down Number of wrong tags that can be tried before stand-down Values in the range 1 to 20 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Time after the wrong tag limit being exceeded before re-trying Amount of time after the wrong tag limit being exceeded that the lock will stand-down for Values in the range 1 to 250 may be set.
The manufacturer defined default value is 250
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The SD-L1000-CH supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.