layout | title |
---|---|
documentation |
YRD446 - ZWave |
{% include base.html %}
This describes the Z-Wave device YRD446, manufactured by ASSA ABLOY with the thing type UID of yale_yrd446_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The YRD446 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the YRD446 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Auto Relock | config_decimal | config_decimal | Number | |
Auto relock time | config_decimal | config_decimal | Number | |
Operating mode | config_decimal | config_decimal | Number | |
Alarm (access) | alarm_access | alarm_access | Door | Switch |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Alarm (raw) | alarm_raw | alarm_raw | String | |
Alarm (general) | alarm_general | alarm_general | Alarm | Switch |
Battery Level | battery-level | Battery | Number | |
Clock Time Offset | time_offset | time_offset | Temperature | Number |
Lock and unlock the door.
The lock_door
channel and is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Generic class for configuration parameter.
The config_decimal
channel and is of type config_decimal
and supports the Number
item.
Generic class for configuration parameter.
The config_decimal
channel and is of type config_decimal
and supports the Number
item.
Generic class for configuration parameter.
The config_decimal
channel and is of type config_decimal
and supports the Number
item.
Indicates if the access control alarm is triggered.
The alarm_access
channel and is of type alarm_access
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a power alarm is triggered.
The alarm_power
channel and is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides alarm parameters as json string.
The alarm_raw
channel and is of type alarm_raw
and supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Indicates if an alarm is triggered.
The alarm_general
channel and is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Channel type information on this channel is not found.
Provides the current time difference for the devices time.
The time_offset
channel and is of type time_offset
and supports the Number
item and is in the Temperature
category.
The following table provides a summary of the 11 configuration parameters available in the YRD446. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Volume | Volume of voice and beeps |
2 | Auto relock | |
3 | Auto relock time | Time for auto relock |
4 | Incorrect PIN limit | Number of incorrect PINs before lockout |
5 | Language | |
7 | Shutdown | Shutdown time after wrong code entries |
8 | Operating mode | |
11 | One Touch Locking | |
12 | Privacy Button | |
13 | Lock Status LED | |
15 | Reset To Factory Defaults | |
Lock Timeout | Sets the time after which the door will auto lock |
Volume of voice and beeps
The following option values may be configured -:
Value | Description |
---|---|
1 | Loud |
2 | Quiet |
3 | Silent |
The manufacturer defined default value is 1
(Loud).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | No auto-relock |
255 | Auto relock |
The manufacturer defined default value is 0
(No auto-relock).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Time for auto relock Number of seconds after the door is unlocked that it will attempt to automatically re-lock itself, if enabled. Values in the range 5 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Number of incorrect PINs before lockout Number of incorrect PINs that can be attempted before lock goes into temporary keypad lockout. Values in the range 1 to 7 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
1 | English |
2 | Spanish |
3 | French |
The manufacturer defined default value is 1
(English).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Shutdown time after wrong code entries
Values in the range 10 to 127 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal |
1 | Vacation |
2 | Privacy |
The manufacturer defined default value is 0
(Normal).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 255
(On).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
1 | Factory Reset |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The YRD446 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | Linked to BASIC |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.