This describes the Z-Wave device MH-P220, manufactured by Zipato with the thing type UID of zipato_mhp220_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The MH-P220 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
MINI ENERGY DIMMER
Conserve energy, save money and enjoy pleasent lightning ambient in your automated home.
DESCRIPTION
Zipato Mini Energy Dimmer provides variable indoor lightning, creating pleasant ambience in your home while helping you reduce overall energy consumption. This Z-Wave enabled module can be set in most existing in-wall switches where it can be used to control connected appliances, with Zipato home automation controllers, Z-Wave remotes or module’s built-in push button.
PRODUCT FEATURES
- Slim, compact Z-Wave incandescent dimmer provides variable indoor lightning, switches your lightning equipment and reports their energy consumption.
- Designed to dim most fluorescent, tungsten, halogen, sodium and leading edge lights
- Fits into most existing in-wall switches
- Resistive load 1x500W @ 220VAC, 1x300W at 120VAC
- Zero-crossing switch
- Reports immediate voltage, current and energy consumption.
- Can act as a repeater in any Z-Wave network
- Very low power consumption
- Easy installation
INCLUDING THE MINI ENERGY DIMMER INTO YOUR NETWORK
- Set the controller into INCLUSION mode. Follow the instructions provided by the controller manufacturer.
- Press the momentary button on the Mini Energy Dimmer, or connected external button S1 3 times in quick succession
Note: If the inclusion is successful, the INDICATION LED will be solid on or off depending on switch’s state. If not, INDICATION LED will blink slowly.
EXCLUDING THE MINI ENERGY DIMMER INTO YOUR NETWORK
- Set the controller into EXCLUSION mode. Follow the instructions provided by the controller manufacturer.
- Press the momentary button on the Mini Energy Dimmer, or the connected S1 button 3 times in quick succession.
Note: If the exclusion is successful, the INDICATION LED will blink slowly. If not, INDICATION LED will be solid on or off depending on switch’s state.
The following table summarises the channels available for the MH-P220 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
The following table provides a summary of the 23 configuration parameters available in the MH-P220. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
0 | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands. |
1 | Dimmer state after power down | Dimmer state saved or not when power is down |
2 | External type switch | Momentary buttons/2-state Switches/S1 dim up, S2 dim down |
3 | 2-state switches | toggle Dimmer without or with specified on/off position |
4 | ALL ON / ALL OFF | forbid/allow ALL ON/ALL OFF |
5 | Minimum brightness level | percentage brightness level |
6 | Maximum brightness level | 2~99 percentage brightness level |
7 | Single dimming step time(Manual) | Max 2.55s, in 10ms steps |
8 | Single dimming step size (Manual) | 1~99 percentage value (modification isn’t recommended) |
9 | Single dimming step time (Auto) | Max 2.55s, in 10ms steps |
10 | Single dimming step size (Auto) | 1~99 percentage value (modification isn’t recommended) |
11 | Timer function (Auto-off) | 0x00 function disabled 0x0001 |
12 | Reversed | Reversed |
13 | One click of S1 | 1~99 percentage value switch |
14 | Double click of S1 | max brightness level |
15 | Operation report Switch1 to Assoc Group 2 & 3 | Dimming level report only valid when holding external button |
16 | Operation report Switch1 to Association Group 2 | Operation report from Switch1 to Association Group 2 |
17 | Switch 2 function | Enable S2 switch, enable Scene Activation and send Basic Set |
18 | Operation report Switch2 to Association Group 4 | Operation report from Switch2 to Association Group 4 |
19 | Scene ID sent to AG1 when one click of S2 | 0 Scene Activation disabled 1~255 send Activation CC to AG1 |
20 | Scene ID sent to AG1 when double click of S2 | 0 Scene Activation disabled 1~255 send Activation CC |
21 | Scene ID sent to AG1 when hold S2 | 0 Scene Activation disabled 1~255 send Activation CC |
255 | Factory setting | 0x55 restore factory setting |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Set the mode for the switch when receiving SWITCH ALL commands. Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
The manufacturer defined default value is 0
(Exclude from All On and All Off groups).
This parameter has the configuration ID config_0_1
and is of type INTEGER
.
Dimmer state saved or not when power is down 0x00 not saved, Dimmer will be off when powered again 0x01 saved, Dimmer will keep the same state when powered again The following option values may be configured -:
Value | Description |
---|---|
0 | not saved |
1 | saved |
The manufacturer defined default value is 1
(saved).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Momentary buttons/2-state Switches/S1 dim up, S2 dim down External switch type
Values in the range 0 to 2 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_2_1 and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | Button |
1 | Toggle |
2 | S1 dim up, S2 dim down |
The manufacturer defined default value is 0
(Button).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
toggle Dimmer without or with specified on/off position 2-state Switches
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_3_1 and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | without specified on/off position |
1 | with specified on/off position |
The manufacturer defined default value is 1
(with specified on/off position).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
forbid/allow ALL ON/ALL OFF ALL ON/ALL OFF
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255.
This parameter has the configuration ID config_4_1 and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | forbid ALL ON, forbid ALL OFF |
0 | forbid ALL ON, allow ALL OFF |
2 | allow ALL ON, forbid ALL OFF |
255 | allow ALL ON, allow ALL OFF |
The manufacturer defined default value is 255
(allow ALL ON, allow ALL OFF).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
percentage brightness level Minimum brightness level
Values in the range 1 to 98 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_5_1 and is of type INTEGER. Values in the range 0 to 98 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
2~99 percentage brightness level Maximum brightness level
Values in the range 2 to 99 may be set.
The manufacturer defined default value is 99.
This parameter has the configuration ID config_6_1 and is of type INTEGER. Values in the range 2 to 99 may be set.
The manufacturer defined default value is 63
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Max 2.55s, in 10ms steps Single dimming step time(Manual)
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3.
This parameter has the configuration ID config_7_2 and is of type INTEGER. Values in the range 1 to 26 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_7_2
and is of type INTEGER
.
1~99 percentage value (modification isn’t recommended) Single dimming step size (Manual)
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_8_1 and is of type INTEGER. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Max 2.55s, in 10ms steps Single dimming step time (Auto)
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3.
This parameter has the configuration ID config_9_2 and is of type INTEGER. Values in the range 1 to 26 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_9_2
and is of type INTEGER
.
1~99 percentage value (modification isn’t recommended) Single dimming step size (Auto)
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_10_1 and is of type INTEGER. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
0x00 function disabled 0x00010x00FF 1s255s
Timer function (Auto-off)
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_11_2 and is of type INTEGER. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
Reversed
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_0
and is of type INTEGER
.
This is a read only parameter.
1~99 percentage value switch One click of S1
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99.
This parameter has the configuration ID config_13_1 and is of type INTEGER. Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
max brightness level Double click of S1
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_14_1 and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | function disabled |
1 | reach max brightness level |
The manufacturer defined default value is 1
(reach max brightness level).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Dimming level report only valid when holding external button Operation report from Switch1 to Association Group 2 & 3
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_15_1 and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | report all |
1 | only report Basic Set ON |
2 | only report Basic Set OFF |
The manufacturer defined default value is 0
(report all).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Operation report from Switch1 to Association Group 2 Operation report from Switch1 to Association Group 2
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_16_1 and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(On).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Enable S2 switch, enable Scene Activation and send Basic Set Switch 2 function
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_17_1 and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | Enable S2 switch |
1 | enable Scene Activation, and send Basic Set ON/OFF |
2 | Scene Activation only |
3 | send Basic ON/ OFF only |
255 | disable S2 Function |
The manufacturer defined default value is 1
(enable Scene Activation, and send Basic Set ON/OFF).
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Operation report from Switch2 to Association Group 4 Operation report from Switch2 to Association Group 4
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_18_1 and is of type INTEGER. The following option values may be configured -:
Value | Description |
---|---|
0 | send Basic ON or Basic OFF |
1 | only send Basic ON |
2 | only send Basic OFF |
255 | no report to AG 4 |
The manufacturer defined default value is 0
(send Basic ON or Basic OFF).
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
0 Scene Activation disabled 1~255 send Activation CC to AG1 Scene ID sent to AG1 when one click of S2
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_19_1 and is of type INTEGER. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
0 Scene Activation disabled 1~255 send Activation CC Scene ID sent to AG1 when double click of S2
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_20_1 and is of type INTEGER. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
0 Scene Activation disabled 1~255 send Activation CC Scene ID sent to AG1 when hold S2
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_21_1 and is of type INTEGER. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
0x55 restore factory setting
0x55 restore factory
setting, write only
The following option values may be configured -:
Value | Description |
---|---|
0 | Default |
85 | restore factory setting |
The manufacturer defined default value is 0
(Default).
This parameter has the configuration ID config_255_1_wo
and is of type INTEGER
.
This is a write only parameter.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MH-P220 supports 4 association groups.
reports device’s dimming state. It supports only one Node ID. A controller / gateway SHOULD be associated to this AG.
Association group 1 supports 1 node.
to control the associated devices synchonously. When S1’s state changes, it will send “Basic Set Command” to these devices.
Association group 2 supports 5 nodes.
to control the associated devices synchronously. When S1’s state changes, it will send “Multi-level Set Command” to these devices.
Association group 3 supports 5 nodes.
to control the associated devices synchronously. When S2’s state changes, it will send “Basic Set Command” to these devices.
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | |
COMMAND_CLASS_SWITCH_ALL_V1 | Linked to BASIC |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |