MH-P220 - ZWave

{% include base.html %}

MH-P220 MINI ENERGY DIMMER

This describes the Z-Wave device MH-P220, manufactured by Zipato with the thing type UID of zipato_mhp220_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

MH-P220 product image

The MH-P220 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

MINI ENERGY DIMMER

Conserve energy, save money and enjoy pleasent lightning ambient in your automated home.

DESCRIPTION

Zipato Mini Energy Dimmer provides variable indoor lightning, creating pleasant ambience in your home while helping you reduce overall energy consumption. This Z-Wave enabled module can be set in most existing in-wall switches where it can be used to control connected appliances, with Zipato home automation controllers, Z-Wave remotes or module’s built-in push button. 

PRODUCT FEATURES

  • Slim, compact Z-Wave incandescent dimmer provides variable indoor lightning, switches your lightning equipment and reports their energy consumption.  
  • Designed to dim most fluorescent, tungsten, halogen, sodium and leading edge lights
  • Fits into most existing in-wall switches
  • Resistive load 1x500W @ 220VAC, 1x300W at 120VAC
  • Zero-crossing  switch
  • Reports immediate voltage, current and energy consumption. 
  • Can act as a repeater in any Z-Wave network
  • Very low power consumption
  • Easy installation

Inclusion Information

INCLUDING THE MINI ENERGY DIMMER INTO YOUR NETWORK

  1. Set the controller into INCLUSION mode. Follow the instructions provided by the controller manufacturer.
  2. Press the momentary button on the Mini Energy Dimmer, or connected external button S1 3 times in quick succession

Note: If the inclusion is successful, the INDICATION LED will be solid on or off depending on switch’s state. If not, INDICATION LED will blink slowly.

Exclusion Information

EXCLUDING THE MINI ENERGY DIMMER INTO YOUR NETWORK

  1. Set the controller into EXCLUSION mode. Follow the instructions provided by the controller manufacturer.
  2. Press the momentary button on the Mini Energy Dimmer, or the connected S1 button 3 times in quick succession.

Note: If the exclusion is successful, the INDICATION LED will blink slowly. If not, INDICATION LED will be solid on or off depending on switch’s state.

Channels

The following table summarises the channels available for the MH-P220 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 23 configuration parameters available in the MH-P220. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands.
1 Dimmer state after power down Dimmer state saved or not when power is down
2 External type switch Momentary buttons/2-state Switches/S1 dim up, S2 dim down
3 2-state switches toggle Dimmer without or with specified on/off position
4 ALL ON / ALL OFF forbid/allow ALL ON/ALL OFF
5 Minimum brightness level percentage brightness level
6 Maximum brightness level 2~99 percentage brightness level
7 Single dimming step time(Manual) Max 2.55s, in 10ms steps
8 Single dimming step size (Manual) 1~99 percentage value (modification isn’t recommended)
9 Single dimming step time (Auto) Max 2.55s, in 10ms steps
10 Single dimming step size (Auto) 1~99 percentage value (modification isn’t recommended)
11 Timer function (Auto-off) 0x00 function disabled 0x00010x00FF 1s255s
12 Reversed Reversed
13 One click of S1 1~99 percentage value switch
14 Double click of S1 max brightness level
15 Operation report Switch1 to Assoc Group 2 & 3 Dimming level report only valid when holding external button
16 Operation report Switch1 to Association Group 2 Operation report from Switch1 to Association Group 2
17 Switch 2 function Enable S2 switch, enable Scene Activation and send Basic Set
18 Operation report Switch2 to Association Group 4 Operation report from Switch2 to Association Group 4
19 Scene ID sent to AG1 when one click of S2 0 Scene Activation disabled 1~255 send Activation CC to AG1
20 Scene ID sent to AG1 when double click of S2 0 Scene Activation disabled 1~255 send Activation CC
21 Scene ID sent to AG1 when hold S2 0 Scene Activation disabled 1~255 send Activation CC
255 Factory setting 0x55 restore factory setting
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 0: Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands. Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER. The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

The manufacturer defined default value is 0 (Exclude from All On and All Off groups).

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 1: Dimmer state after power down

Dimmer state saved or not when power is down 0x00 not saved, Dimmer will be off when powered again 0x01 saved, Dimmer will keep the same state when powered again The following option values may be configured -:

Value Description
0 not saved
1 saved

The manufacturer defined default value is 1 (saved).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: External type switch

Momentary buttons/2-state Switches/S1 dim up, S2 dim down External switch type

Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_1 and is of type INTEGER. The following option values may be configured -:

Value Description
0 Button
1 Toggle
2 S1 dim up, S2 dim down

The manufacturer defined default value is 0 (Button).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: 2-state switches

toggle Dimmer without or with specified on/off position 2-state Switches

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER. The following option values may be configured -:

Value Description
0 without specified on/off position
1 with specified on/off position

The manufacturer defined default value is 1 (with specified on/off position).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: ALL ON / ALL OFF

forbid/allow ALL ON/ALL OFF ALL ON/ALL OFF

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_4_1 and is of type INTEGER. The following option values may be configured -:

Value Description
0 forbid ALL ON, forbid ALL OFF
0 forbid ALL ON, allow ALL OFF
2 allow ALL ON, forbid ALL OFF
255 allow ALL ON, allow ALL OFF

The manufacturer defined default value is 255 (allow ALL ON, allow ALL OFF).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Minimum brightness level

percentage brightness level Minimum brightness level

Values in the range 1 to 98 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_5_1 and is of type INTEGER. Values in the range 0 to 98 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Maximum brightness level

2~99 percentage brightness level Maximum brightness level

Values in the range 2 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_6_1 and is of type INTEGER. Values in the range 2 to 99 may be set.

The manufacturer defined default value is 63.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Single dimming step time(Manual)

Max 2.55s, in 10ms steps Single dimming step time(Manual)

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_7_2 and is of type INTEGER. Values in the range 1 to 26 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: Single dimming step size (Manual)

1~99 percentage value (modification isn’t recommended) Single dimming step size (Manual)

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER. Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Single dimming step time (Auto)

Max 2.55s, in 10ms steps Single dimming step time (Auto)

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_9_2 and is of type INTEGER. Values in the range 1 to 26 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: Single dimming step size (Auto)

1~99 percentage value (modification isn’t recommended) Single dimming step size (Auto)

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_10_1 and is of type INTEGER. Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Timer function (Auto-off)

0x00 function disabled 0x00010x00FF 1s255s Timer function (Auto-off)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Reversed

Reversed

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_0 and is of type INTEGER. This is a read only parameter.

Parameter 13: One click of S1

1~99 percentage value switch One click of S1

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_13_1 and is of type INTEGER. Values in the range 0 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Double click of S1

max brightness level Double click of S1

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_14_1 and is of type INTEGER. The following option values may be configured -:

Value Description
0 function disabled
1 reach max brightness level

The manufacturer defined default value is 1 (reach max brightness level).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Operation report Switch1 to Assoc Group 2 & 3

Dimming level report only valid when holding external button Operation report from Switch1 to Association Group 2 & 3

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_15_1 and is of type INTEGER. The following option values may be configured -:

Value Description
0 report all
1 only report Basic Set ON
2 only report Basic Set OFF

The manufacturer defined default value is 0 (report all).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: Operation report Switch1 to Association Group 2

Operation report from Switch1 to Association Group 2 Operation report from Switch1 to Association Group 2

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_16_1 and is of type INTEGER. The following option values may be configured -:

Value Description
0 Off
1 On

The manufacturer defined default value is 1 (On).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Switch 2 function

Enable S2 switch, enable Scene Activation and send Basic Set Switch 2 function

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_17_1 and is of type INTEGER. The following option values may be configured -:

Value Description
0 Enable S2 switch
1 enable Scene Activation, and send Basic Set ON/OFF
2 Scene Activation only
3 send Basic ON/ OFF only
255 disable S2 Function

The manufacturer defined default value is 1 (enable Scene Activation, and send Basic Set ON/OFF).

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: Operation report Switch2 to Association Group 4

Operation report from Switch2 to Association Group 4 Operation report from Switch2 to Association Group 4

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_18_1 and is of type INTEGER. The following option values may be configured -:

Value Description
0 send Basic ON or Basic OFF
1 only send Basic ON
2 only send Basic OFF
255 no report to AG 4

The manufacturer defined default value is 0 (send Basic ON or Basic OFF).

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: Scene ID sent to AG1 when one click of S2

0 Scene Activation disabled 1~255 send Activation CC to AG1 Scene ID sent to AG1 when one click of S2

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_19_1 and is of type INTEGER. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: Scene ID sent to AG1 when double click of S2

0 Scene Activation disabled 1~255 send Activation CC Scene ID sent to AG1 when double click of S2

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_20_1 and is of type INTEGER. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Scene ID sent to AG1 when hold S2

0 Scene Activation disabled 1~255 send Activation CC Scene ID sent to AG1 when hold S2

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_21_1 and is of type INTEGER. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 255: Factory setting

0x55 restore factory setting 0x55 restore factory
setting, write only The following option values may be configured -:

Value Description
0 Default
85 restore factory setting

The manufacturer defined default value is 0 (Default).

This parameter has the configuration ID config_255_1_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MH-P220 supports 4 association groups.

Group 1: Reports device’s dimming state

reports device’s dimming state. It supports only one Node ID. A controller / gateway SHOULD be associated to this AG.

Association group 1 supports 1 node.

Group 2: S1 Basic Set Command

to control the associated devices synchonously. When S1’s state changes, it will send “Basic Set Command” to these devices.

Association group 2 supports 5 nodes.

Group 3: S1 Multi-level Set Command

to control the associated devices synchronously. When S1’s state changes, it will send “Multi-level Set Command” to these devices.

Association group 3 supports 5 nodes.

Group 4: S2 Basic Set Command

to control the associated devices synchronously. When S2’s state changes, it will send “Basic Set Command” to these devices.

Association group 4 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2
COMMAND_CLASS_SWITCH_ALL_V1 Linked to BASIC
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links