PSP02 Door/temp/illumination/motion sensor

This describes the Z-Wave device PSP02, manufactured by Zipato with the thing type UID of zipato_phpsp02_00_000.

The device is in the category of Door, defining Door sensors.

PSP02 product image

The PSP02 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The PSP02 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Door/Window, motion, temperature and illumination sensor in one device.

Primarily used as Door/Window sensor, it consists of two parts: magnet and a sensor.

  • Very low power consumption.
  • Low battery battery indication.
  • Door/Window status and battery status auto-report.
  • LED indicator.
  • Over-the-air firmware update.
  • Tamper proof protection.

Inclusion Information

Put the Z-Wave Controller in inclusion mode.

Pressing tamper key three times within 1.5 seconds will enter inclusion mode.

After successful inclusion, the device will wake to receive the setting command from the Z-Wave Controller in about 20 seconds.

Exclusion Information

Put the Z-Wave Controller in exclusion mode.

Pressing tamper key three times within 1.5 seconds will enter exclusion mode. Node ID has been excluded.

Wakeup Information

The PSP02 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Any action.

Channels

The following table summarises the channels available for the PSP02 -:

Channel Channel Id Category Item Type
Door/Window sensor sensor_door Door Contact
Sensor(temperature) sensor_temperature Temperature Number:Temperature
Sensor(luminance) sensor_luminance Number
Motion Alarm alarm_motion Door Switch
Battery Level battery-level Battery Number
Alarm(general) alarm_general Door Switch

Door/Window sensor

Indicates if the door/window is open or closed.

The sensor_door channel supports the Contact item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Contact item type -:

Value Label
OPEN Open
CLOSED Closed

Sensor(temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number:Temperature item and is in the Temperature category.

Sensor(luminance)

Indicates the current light reading.

The sensor_luminance channel supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Motion Alarm

Indicates if a motion alarm is triggered.

The alarm_motion channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Alarm(general)

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 30 configuration parameters available in the PSP02. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Basic Set Level Basic command to turn on the light
3 PIR Sensitivity setting
4 Light Threshold setting
5 Operation mode set test mode if DIP switch in customer mode
5 disable the door/window function Disable/Enable the function
5 temperature unit set the temperature unit
5 Disable illumination reports toggle illumination reports
5 Disable temperature reports Disable/enable temperature reports
5 back key release action Disable/enable the back key release into test mode
6 magnetic integration for lighting control switch control
6 PIR integration to control lighting PIR integration
6 magetic/pir integration control lighting in association group 2
6 device and lighting in same room device and lighting in same room
6 disable delay to turn off the light disable/enable delay
6 light off control disable/enable auto turn off the light
7 motion off report enable motion OFF report
7 PIR super-sensitivity enable PIR super-sensitivity
7 BASIC OFF report Disable/enable report after door closed
7 door closed report type notification or sensor binary report
7 multi CC in auto report disable/enable multi CC in report
7 Battery state reports disable/enable battery state reports
8 PIR motion re-trigger min interval PIR motion re-trigger min interval
9 Light on time hysteresis time to keep the light on without motion
10 battery level auto-report interval battery level auto-report interval
11 door state report interval door state report interval
12 illumination auto report interval illumination auto report interval
13 temperature report interval temperature report interval
20 tick duration auto-reports tick duration
21 temperature differential to report temperature differential to report
22 min illumination differential min illumination differential to report
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 2: Basic Set Level

Basic command to turn on the light Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. The following option values may be configured, in addition to values in the range 0 to 255 -:

Value Description
0 Off
255 On

The manufacturer defined default value is 255 (On).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: PIR Sensitivity

setting PIR sensitivity settings. 0 means disable the PIR motion. 1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequently. Values in the range 0 to 99 may be set.

The manufacturer defined default value is 80.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Light Threshold

setting Setting the illumination threshold to turn on the light. When the event is triggered and the environment illumination is lower than the threshold, the device will turn on the light. 0 means turn off illumination detection function, and never turn on the light.

  • 1 means darkest.
  • 99 means brightest.
  • 100 means turn off illumination detection function, and always turn on the light.

Notice: In test mode, only the value in 1 to 99 will enable the illumination detection function and update the illumination value. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Operation mode

set test mode if DIP switch in customer mode Bit1: 1 means test mode, 0 means normal mode.

Notice: This bit only effect by the DIP Switch setting to “customer mode”, otherwise it is decided by DIP Switch setting to Test or Normal Mode.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Normal mode
2 test mode

The manufacturer defined default value is 0 (Normal mode).

This parameter has the configuration ID config_5_1_00000002 and is of type INTEGER.

Parameter 5: disable the door/window function

Disable/Enable the function Bit2: Disable the door/window function. (1:Disable, 0:Enable).This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable the door/window function
1 disable the door/window function

The manufacturer defined default value is 0 (enable the door/window function).

This parameter has the configuration ID config_5_1_00000004 and is of type INTEGER.

Parameter 5: temperature unit

set the temperature unit Bit3: temperature scale. 0: Fahrenheit, 1:CelsiusThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Fahrenheit
8 Celsius

The manufacturer defined default value is 0 (Fahrenheit).

This parameter has the configuration ID config_5_1_00000008 and is of type INTEGER.

Parameter 5: Disable illumination reports

toggle illumination reports Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
16 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_5_1_00000010 and is of type INTEGER.

Parameter 5: Disable temperature reports

Disable/enable temperature reports Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
32 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_5_1_00000020 and is of type INTEGER.

Parameter 5: back key release action

Disable/enable the back key release into test mode Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
128 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_5_1_00000080 and is of type INTEGER.

Parameter 6: magnetic integration for lighting control

switch control Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2.

(1:Disable, 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
1 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_6_1_00000001 and is of type INTEGER.

Parameter 6: PIR integration to control lighting

PIR integration Bit1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2.
(1:Disable, 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
2 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_6_1_00000002 and is of type INTEGER.

Parameter 6: magetic/pir integration

control lighting in association group 2 Bit2: Disable magnetic integrate PIR to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable, default is Disable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
4 disable

The manufacturer defined default value is 4 (disable).

This parameter has the configuration ID config_6_1_00000004 and is of type INTEGER.

Parameter 6: device and lighting in same room

device and lighting in same room Bit3: When Bit2 is 0 (Enable), Are the device and the lighting in the same room? 0: In the same room (Default), 1: In the different room.

Notice: If this bit is 1, it is recommended also set the Bit1 to 1, cause the PIR triggered, doesn’t mean the people in that room.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 same room
8 different rooms

The manufacturer defined default value is 0 (same room).

This parameter has the configuration ID config_6_1_00000008 and is of type INTEGER.

Parameter 6: disable delay to turn off the light

disable/enable delay Bit4: Disable delay 5 seconds to turn off the light, when door/window closed. (1:Disable, 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
16 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_6_1_00000010 and is of type INTEGER.

Parameter 6: light off control

disable/enable auto turn off the light Bit5: Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable)

Notice: If bit2 is zero, this setting is useless. If the configuration No.9 is zero, this setting is useless.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
32 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_6_1_00000020 and is of type INTEGER.

Parameter 7: motion off report

enable motion OFF report Bit1: Enable sending motion OFF report. (0:Disable, 1:Enable)

Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 disable
2 enable

The manufacturer defined default value is 0 (disable).

This parameter has the configuration ID config_7_1_00000002 and is of type INTEGER.

Parameter 7: PIR super-sensitivity

enable PIR super-sensitivity Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 disable
4 enable

The manufacturer defined default value is 4 (enable).

This parameter has the configuration ID config_7_1_00000004 and is of type INTEGER.

Parameter 7: BASIC OFF report

Disable/enable report after door closed Bit3: Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
8 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_7_1_00000008 and is of type INTEGER.

Parameter 7: door closed report type

notification or sensor binary report Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 notification report
16 sensor binary report

The manufacturer defined default value is 0 (notification report).

This parameter has the configuration ID config_7_1_00000010 and is of type INTEGER.

Parameter 7: multi CC in auto report

disable/enable multi CC in report Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
32 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_7_1_00000020 and is of type INTEGER.

Parameter 7: Battery state reports

disable/enable battery state reports Bit6: Disable to report battery state when the device triggered. (1:Disable 0:Enable)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 enable
64 disable

The manufacturer defined default value is 0 (enable).

This parameter has the configuration ID config_7_1_00000040 and is of type INTEGER.

Parameter 8: PIR motion re-trigger min interval

PIR motion re-trigger min interval In normal mode, after the PIR motion detection, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds). Setting the suitable value to prevent sending the trigger signal too frequently. Also can save the battery energy.

Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR  start detecting again.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1_0000007F and is of type INTEGER.

Parameter 9: Light on time hysteresis

time to keep the light on without motion After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not
detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_9_1_0000007F and is of type INTEGER.

Parameter 10: battery level auto-report interval

battery level auto-report interval The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can be set by the configuration parameter No.20.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_10_1_0000007F and is of type INTEGER.

Parameter 11: door state report interval

door state report interval The interval time for auto reporting the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can be set by the configuration parameter No.20.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_11_1_0000007F and is of type INTEGER.

Parameter 12: illumination auto report interval

illumination auto report interval The interval time for auto report the illumination. 0 means turn off auto report illumination. The
default value is 12. The tick time can be set by the configuration parameter No.20.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_12_1_0000007F and is of type INTEGER.

Parameter 13: temperature report interval

temperature report interval The interval time for a temperature auto report. default=12, 0=no auto-report. Tick duration set by parameter 20.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_13_1_0000007F and is of type INTEGER.

Parameter 20: tick duration

auto-reports tick duration The interval time for auto report each tick. Setting this configuration will effect configuration
No.10, No.11, No.12 and No.13.
Caution: Setting to 0 means turn off all auto report function.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: temperature differential to report

temperature differential to report The temperature differential to report. 0 means turn off this function. The unit is in Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the “Temperature Report” sectionThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_21_1_0000007F and is of type INTEGER.

Parameter 22: min illumination differential

min illumination differential to report The illumination differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the “Illumination Report” section.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 63 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_22_1_0000003F and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PSP02 supports 2 association groups.

Group 1: Reports target.

group to send reports to

Association group 1 supports 8 nodes.

Group 2: Basic Set target

group to send Basic Set light commands to

Association group 2 supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SENSOR_ALARM_V1