layout | title |
---|---|
documentation |
ZEN21 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZEN21, manufactured by Zooz with the thing type UID of zooz_zen21_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN21 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Z-WAVE ON/OFF SWITCH
- Bring your Z-Wave gateway hub or controller as close to the switch as possible
- Put your Z-Wave controller into inclusion mode
- Tap the upper paddle of the switch 3 times very quickly to finalize the inclusion process
- Bring your Z-Wave gateway hub or controller as close to the switch as possible
- Put your Z-Wave controller into exclusion mode
- Tap the lower paddle of the switch 3 times very quickly to finalize the exclusion process
The following table summarises the channels available for the ZEN21 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 3 configuration parameters available in the ZEN21. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Paddle Control | Reverse switch direction |
2 | LED Indicator Control | LED Indicator Control |
3 | LED Indicator | Enable / Disable LED Indicator |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Reverse switch direction Choose if you want the upper paddle to turn the light on or turn the light off when tapped The following option values may be configured -:
Value | Description |
---|---|
0 | Top-ON, Bottom-OFF |
1 | Top-OFF, Bottom-ON |
The manufacturer defined default value is 0
(Top-ON, Bottom-OFF).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
LED Indicator Control Choose if you want the LED indicator to turn on when the switch (light) is on or off The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON - Switch OFF |
1 | LED ON - Switch ON |
The manufacturer defined default value is 0
(LED ON - Switch OFF).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Enable / Disable LED Indicator Enable / Disable LED Indicator The following option values may be configured -:
Value | Description |
---|---|
0 | LED Enabled |
1 | LED Disabled |
The manufacturer defined default value is 0
(LED Enabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN21 supports 1 association group.
This device will send SWITCH BINARY REPORT to Group 1 when operated manually. Depending on your Z-Wave gateway's home automation software capabilities, you may be able to associate your Z-Wave switch in groups with other Z-Wave devices to schedule scenes and create events. This on off switch supports Group 1 with up to five devices for lifeline communication. This device will send SWITCH BINARY REPORT to Group 1 when operated manually. Please refer to your controller's user guide for advanced programming instructions as they are a little different for every software.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.