layout title
documentation
ZEN21 - ZWave

{% include base.html %}

ZEN21 Light Switch

This describes the Z-Wave device ZEN21, manufactured by Zooz with the thing type UID of zooz_zen21_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZEN21 product image

The ZEN21 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-WAVE ON/OFF SWITCH

Inclusion Information

  1. Bring your Z-Wave gateway hub or controller as close to the switch as possible
  2. Put your Z-Wave controller into inclusion mode
  3. Tap the upper paddle of the switch 3 times very quickly to finalize the inclusion process

Exclusion Information

  1. Bring your Z-Wave gateway hub or controller as close to the switch as possible
  2. Put your Z-Wave controller into exclusion mode
  3. Tap the lower paddle of the switch 3 times very quickly to finalize the exclusion process

Channels

The following table summarises the channels available for the ZEN21 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the ZEN21. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Paddle Control Reverse switch direction
2 LED Indicator Control LED Indicator Control
3 LED Indicator Enable / Disable LED Indicator
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Paddle Control

Reverse switch direction Choose if you want the upper paddle to turn the light on or turn the light off when tapped The following option values may be configured -:

Value Description
0 Top-ON, Bottom-OFF
1 Top-OFF, Bottom-ON

The manufacturer defined default value is 0 (Top-ON, Bottom-OFF).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: LED Indicator Control

LED Indicator Control Choose if you want the LED indicator to turn on when the switch (light) is on or off The following option values may be configured -:

Value Description
0 LED ON - Switch OFF
1 LED ON - Switch ON

The manufacturer defined default value is 0 (LED ON - Switch OFF).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: LED Indicator

Enable / Disable LED Indicator Enable / Disable LED Indicator The following option values may be configured -:

Value Description
0 LED Enabled
1 LED Disabled

The manufacturer defined default value is 0 (LED Enabled).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZEN21 supports 1 association group.

Group 1: Status

This device will send SWITCH BINARY REPORT to Group 1 when operated manually. Depending on your Z-Wave gateway's home automation software capabilities, you may be able to associate your Z-Wave switch in groups with other Z-Wave devices to schedule scenes and create events. This on off switch supports Group 1 with up to five devices for lifeline communication. This device will send SWITCH BINARY REPORT to Group 1 when operated manually. Please refer to your controller's user guide for advanced programming instructions as they are a little different for every software.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2