layout title
documentation
ZEN26 - ZWave

{% include base.html %}

ZEN26 Z-Wave Plus S2 ON/OFF Switch

This describes the Z-Wave device ZEN26, manufactured by Zooz with the thing type UID of zooz_zen26_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZEN26 product image

The ZEN26 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Manual or Z-Wave on/off control with instant status updates

Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed (neutral wire required)

Remembers and restores on/off status after power failure

LED indicator signals inclusion, exclusion, reset, and setting changes

Built-in Z-Wave Plus signal repeater to extend network range

Works with LED, CFL, and incandescent bulbs

S2 security protocol and the latest 500 Z-Wave chip for faster and safer wireless communication

Supported by most Z-Wave controllers

Inclusion Information

TAP Upper paddle 3-5 TIMES QUICKLY

The LED indicator will blink to signal communication and remain on for 2 seconds to confirm inclusion

Exclusion Information

 Tap the lower paddle on the switch 3 times quickly

General Usage Information

To complete factory reset process manually, tap-tap-tap’n’hold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset. NOTE: All previously recorded activity and custom settings will be erased from the device’s memory

Channels

The following table summarises the channels available for the ZEN26 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the ZEN26. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Paddle Control Choose Paddle Functionality (Invert)
2 LED Indicator Control Change behavior of the LED indicator
3 Auto Turn-Off Timer enable the Auto Turn-Off Timer
5 On Off Status After Power Failure Set the on off status for the switch after power failure.

Parameter 1: Paddle Control

Choose Paddle Functionality (Invert) Choose if you want the upper paddle to turn the light on or turn the light off when tapped The following option values may be configured -:

Value Description
0 Top on, Bottom off
1 Top off, Bottom on

The manufacturer defined default value is 0 (Top on, Bottom off).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: LED Indicator Control

Change behavior of the LED indicator Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times

OR

6 x TAP PADDLE to change the LED indicator mode The following option values may be configured -:

Value Description
0 LED on when switch off
1 LED on when switch on
2 LED off
3 LED on

The manufacturer defined default value is 0 (LED on when switch off).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Auto Turn-Off Timer

enable the Auto Turn-Off Timer Use this parameter to set the time which you want the switch to automatically turn off once it has been turned on. The number entered as value corresponds to the number of seconds. Values in the range 0 to 32768 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 5: On Off Status After Power Failure

Set the on off status for the switch after power failure. Set the on off status for the switch after power failure. The following option values may be configured -:

Value Description
0 Off
1 On
2 last state

The manufacturer defined default value is 2 (last state).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZEN26 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. This device will send BINARY SWITCH REPORT to Group 1 and 2 when operated manually

Association group 1 supports 1 node.

Group 2: Control

This device will send BINARY SWITCH REPORT to Group 1 and 2 when operated manually

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Documentation Links