06436 Insert blind control

This describes the Z-Wave device 06436, manufactured by Z-Wave.Me with the thing type UID of zwaveme_06436_00_000.

06436 product image

The 06436 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the 06436 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Blinds Control blinds_control Blinds Rollershutter

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Blinds Control

Provides start / stop control of blinds.

The blinds_control channel supports the Rollershutter item and is in the Blinds category.

Device Configuration

The following table provides a summary of the 17 configuration parameters available in the 06436. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED mode Set LED indication mode
2 Automatically open or close after Automatically open or close blind after time
3 What to do on RF close command Defines how to interpret RF Off command.
4 Full close time Time in seconds to go from opened to closed state.
5 Full open time Time in seconds to go from closed to open state.
6 Node ID of the blocking device Id of the device which can block the blinds
7 On which command from blocking node to enable the protection Defines which command from blocking device to interpret as closed door and hence, unprotected.
8 Stop or Revert if opposite button is pressed Defines behaviour on open press while closing and vice versa.
9 Invert open and close relays Allows exchanging open and close relays if blind control is wired to the motor incorrectly
10 Typical click timeout Typical time used to differentiate click, hold and double and triple clicks in 10ms units
11 Invert buttons Allows exchanging the functionality of the buttons
12 Switch by buttons Local operations by buttons will/will not/ switch the load
13 Action on button single press or hold Defines which command should be sent on button single press or hold.
14 Action on button double press or hold Defines which command should be sent on button double press or press-hold.
15 Send the following Switch All commands Defines what to do when a Switch All command arrives.
16 What to do on button Down press Defines how to interpret button Down press. Depends on 'Switch by buttons' parameter.
17 Action on Auto open or close function Defines the action to perform upon auto open or auto close.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: LED mode

Set LED indication mode

The following option values may be configured -:

Value Description
0 Disabled
1 Show working state
2 Show idle state
3 Operated by Indicator Command Class
4 Show if not closed

The manufacturer defined default value is 3 (Operated by Indicator Command Class).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Automatically open or close after

Automatically open or close blind after time If not zero, automatically open or close blind after a user defined time The following option values may be configured -:

Value Description
0 Disabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: What to do on RF close command

Defines how to interpret RF Off command. Defines how to interpret RF Off command. Can be used in conjunction with Auto Close function: Ignore - to open the door by motion detectors and close it back after some amount of time: in case of multiple motion detectors each would try to open that would break logics; Open - to open on both On and Off paddle press on the remote and close after some amount of time. Button close click will still work (if button operations are not disabled). Note that Dim Down command will still begin close motion. The following option values may be configured -:

Value Description
0 Close
1 Ignore
2 Open
3 Open if closed else close

The manufacturer defined default value is 0 (Close).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Full close time

Time in seconds to go from opened to closed state. Time to go from opened to closed state. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close. The following option values may be configured, in addition to values in the range 0 to 255 -:

Value Description
0 Keep in permanent motion

The manufacturer defined default value is 60.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Full open time

Time in seconds to go from closed to open state. Time to go from closed to open state. This value may differ from Full close time for some blinds due to gravity. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close. The following option values may be configured, in addition to values in the range 0 to 255 -:

Value Description
0 Keep in permanent motion

The manufacturer defined default value is 60.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Node ID of the blocking device

Id of the device which can block the blinds Id of the device which commands would be interpreted not as Open/Close, but as block/unblock. Usefull with door opening detector: if the door is open, block the blind not to break shades while they move. The following option values may be configured -:

Value Description
0 Disabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: On which command from blocking node to enable the protection

Defines which command from blocking device to interpret as closed door and hence, unprotected.

The following option values may be configured -:

Value Description
0 on On
1 on Off

The manufacturer defined default value is 0 (on On).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Stop or Revert if opposite button is pressed

Defines behaviour on open press while closing and vice versa. Defines behaviour on open press while closing and vice versa. To allow Stop behavior when switched by remote, use Stop by Basic The following option values may be configured -:

Value Description
0 Stop (by buttons and Binary)
1 Revert
2 Stop (by buttons, Binary and Basic)

The manufacturer defined default value is 0 (Stop (by buttons and Binary)).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Invert open and close relays

Allows exchanging open and close relays if blind control is wired to the motor incorrectly

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Typical click timeout

Typical time used to differentiate click, hold and double and triple clicks in 10ms units

Values in the range 1 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Invert buttons

Allows exchanging the functionality of the buttons

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Switch by buttons

Local operations by buttons will/will not/ switch the load If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. The following option values may be configured -:

Value Description
0 No
1 By single press and hold
2 By double press and hold

The manufacturer defined default value is 1 (By single press and hold).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Action on button single press or hold

Defines which command should be sent on button single press or hold. Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. The following option values may be configured -:

Value Description
0 Disabled
1 Switch On/Off (send Basic Set)
2 Switch All
3 Send Scenes
4 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
5 Send Preconfigured Scenes

The manufacturer defined default value is 4 (Switch On/Off and Dim (send Basic Set and Switch Multilevel)).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Action on button double press or hold

Defines which command should be sent on button double press or press-hold. Defines which command should be sent on button double press or press-hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands The following option values may be configured -:

Value Description
0 Disabled
1 Switch On/Off (send Basic Set)
2 Switch All
3 Send Scenes
4 Switch On/Off (send Basic Set)Switch On/Off and Dim (send Basic Set an
5 Send Preconfigured Scenes

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Send the following Switch All commands

Defines what to do when a Switch All command arrives.

The following option values may be configured -:

Value Description
1 Switch off only
2 Switch on only
255 Switch all on and off

The manufacturer defined default value is 1 (Switch off only).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: What to do on button Down press

Defines how to interpret button Down press. Depends on 'Switch by buttons' parameter. Defines how to interpret button Down press. Depends on "Switch by buttons" parameter. If not Disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with Auto Off function. The following option values may be configured -:

Value Description
0 Close
1 Open if closed else close
2 Open

The manufacturer defined default value is 0 (Close).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Action on Auto open or close function

Defines the action to perform upon auto open or auto close.

The following option values may be configured -:

Value Description
0 Close blinds
1 Open blinds

The manufacturer defined default value is 0 (Close blinds).

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 06436 supports 3 association groups.

Group 1: Single press and hold of up/down buttons

Association group 1 supports 8 nodes.

Group 2: Double press and press-hold of up/down buttons

Association group 2 supports 8 nodes.

Group 3: Send Reports on blind state change

Association group 3 supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_HAIL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1