Skip to content

Latest commit

 

History

History
432 lines (263 loc) · 16.9 KB

zme05461_0_0.md

File metadata and controls

432 lines (263 loc) · 16.9 KB
layout title
documentation
ZME_05461 - ZWave

{% include base.html %}

ZME_05461 Double switch

This describes the Z-Wave device ZME_05461, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme05461_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

The ZME_05461 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZME_05461 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number
Switch 1 switch_binary1 Switch Switch
Electric meter (kWh) 1 meter_kwh1 Energy Number
Electric meter (watts) 1 meter_watts1 Energy Number
Switch 2 switch_binary2 Switch Switch
Electric meter (kWh) 2 meter_kwh2 Energy Number
Electric meter (watts) 2 meter_watts2 Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 15 configuration parameters available in the ZME_05461. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Set LED indication mode
2 Automatically switch off first channel after If not zero, automatically switch off after a user defined time
3 Function of RF off command on first channel Defines how to interpret RF first channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try
4 Switch on/off by holding buttons Defines if the switch should change it state to on/off if buttons are being hold.
5 Restore switch state after power cycle Defines if the switch should restore switch state to the last state prior to device power off (power cycle).
11 Invert buttons Allows for exchanging ON and OFF.
12 Switch by buttons (first channel) If disabled, the local operations by buttons will not switch relay on first channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote de
13 Action on button single press or hold Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.
14 Action on button double press or hold Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.
16 What to do on button Down press (for both channels) Defines how to interpret button Down press. Depends on parameters 12 and 32 'Switch by buttons' parameter. If not Disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with Auto Off function.
20 Energy consumption for first channel Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.
22 Automatically switch off second channel after If not zero, automatically switch off after a user defined time
23 Function of RF off command on second channel Defines how to interpret RF second channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try
32 Switch by buttons (second channel) If disabled, the local operations by buttons will not switch relay on second channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote d
40 Energy consumption for second channel Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Set LED indication mode

The following option values may be configured -:

Value Description
0 Disabled
1 Show switch state
2 night light (inverted state)

The manufacturer defined default value is 1 (Show switch state).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Automatically switch off first channel after

If not zero, automatically switch off after a user defined time

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Function of RF off command on first channel

Defines how to interpret RF first channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try

The following option values may be configured -:

Value Description
0 Switch OFF
1 Ignore
2 Switch ON
3 Switch on if load is off else switch off

The manufacturer defined default value is 0 (Switch OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Switch on/off by holding buttons

Defines if the switch should change it state to on/off if buttons are being hold.

The following option values may be configured -:

Value Description
0 No
1 Yes (only for the first channel)
2 Yes (only for the second channel)
3 Yes (for both channels)

The manufacturer defined default value is 1 (Yes (only for the first channel)).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Restore switch state after power cycle

Defines if the switch should restore switch state to the last state prior to device power off (power cycle).

The following option values may be configured -:

Value Description
0 No, turn off
1 Yes (only for the first channel)
2 Yes (only for the second channel)
3 Yes (for both channels)

The manufacturer defined default value is 1 (Yes (only for the first channel)).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 11: Invert buttons

Allows for exchanging ON and OFF.

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Switch by buttons (first channel)

If disabled, the local operations by buttons will not switch relay on first channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote de

The following option values may be configured -:

Value Description
0 No
1 By single press and hold
2 By double press and press-hold

The manufacturer defined default value is 1 (By single press and hold).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Action on button single press or hold

Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.

The following option values may be configured -:

Value Description
0 Disabled
1 Switch On/Off only (send Basic Set)
2 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
3 Scene activation

The manufacturer defined default value is 2 (Switch On/Off and Dim (send Basic Set and Switch Multilevel)).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Action on button double press or hold

Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.

The following option values may be configured -:

Value Description
0 Disabled
1 Switch On/Off only (send Basic Set)
2 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
3 Scene activation

The manufacturer defined default value is 2 (Switch On/Off and Dim (send Basic Set and Switch Multilevel)).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 16: What to do on button Down press (for both channels)

Defines how to interpret button Down press. Depends on parameters 12 and 32 'Switch by buttons' parameter. If not Disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with Auto Off function.

The following option values may be configured -:

Value Description
0 Switch off
1 Switch On if load is Off, else switch Off
2 Switch on

The manufacturer defined default value is 1 (Switch On if load is Off, else switch Off).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 20: Energy consumption for first channel

Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.

The following option values may be configured -:

Value Description
0 Disabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_20_2 and is of type INTEGER.

Parameter 22: Automatically switch off second channel after

If not zero, automatically switch off after a user defined time

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_22_2 and is of type INTEGER.

Parameter 23: Function of RF off command on second channel

Defines how to interpret RF second channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try

The following option values may be configured -:

Value Description
0 Switch OFF
1 Ignore
2 Switch ON
3 Switch on if load is off else switch off

The manufacturer defined default value is 0 (Switch OFF).

This parameter has the configuration ID config_23_1 and is of type INTEGER.

Parameter 32: Switch by buttons (second channel)

If disabled, the local operations by buttons will not switch relay on second channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote d

The following option values may be configured -:

Value Description
0 No
1 By single press and hold
2 By double press and press-hold

The manufacturer defined default value is 2 (By double press and press-hold).

This parameter has the configuration ID config_32_1 and is of type INTEGER.

Parameter 40: Energy consumption for second channel

Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.

The following option values may be configured -:

Value Description
0 Disabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_40_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZME_05461 supports 3 association groups.

Group 1: Group 1

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Group 3: Group 3

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.