ZME_06437 Wall Plug Switch

This describes the Z-Wave device ZME_06437, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme06437_00_000.

ZME_06437 product image

The ZME_06437 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZME_06437 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the ZME_06437. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Set LED indication mode
2 Automatic switch off If not zero, automatically switch off after a user defined time
3 Function of RF off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the
5 Restore switch state after power cycle Defines if the switch should restore switch state to the last state prior to device power off (power cycle).
20 Energy consumption Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.
21 Off Color
22 On Color
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Set LED indication mode

The following option values may be configured -:

Value Description
0 Disabled
1 Show switch state
2 Operated by Indicator Command Class

The manufacturer defined default value is 2 (Operated by Indicator Command Class).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Automatic switch off

If not zero, automatically switch off after a user defined time

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Function of RF off command

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the

The following option values may be configured -:

Value Description
0 Switch OFF
1 Ignore
2 Switch ON
3 Switch on if load is off else switch off

The manufacturer defined default value is 0 (Switch OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 5: Restore switch state after power cycle

Defines if the switch should restore switch state to the last state prior to device power off (power cycle).

The following option values may be configured -:

Value Description
0 No, turn off
1 Yes (Default)

The manufacturer defined default value is 1 (Yes (Default)).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 20: Energy consumption

Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.

Values in the range 0 to 1800 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_20_2 and is of type INTEGER.

Parameter 21: Off Color

The following option values may be configured -:

Value Description
0 Off
1 Red
2 Green
3 Blue
4 Yellow

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 22: On Color

The following option values may be configured -:

Value Description
0 Off
1 Red
2 Green
3 Blue
4 Yellow

The manufacturer defined default value is 3 (Blue).

This parameter has the configuration ID config_22_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZME_06437 supports 2 association groups.

Group 1: Group 1

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1

Documentation Links