Notifications
You must be signed in to change notification settings - Fork 3
Expand file tree
/
Copy pathuFrameMetadata.pas
More file actions
259 lines (223 loc) · 7.88 KB
/
Copy pathuFrameMetadata.pas
File metadata and controls
259 lines (223 loc) · 7.88 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
unit uFrameMetadata;
{ The metadata view: everything the model's simulation-metadata block
defines, and everything wrong with it.
This panel exists because the format's one genuinely silent failure mode
is invisibility. A metadata block lives inside a comment, so a user who
did not write the file has no reason to know it is there, and a block
that was not recognised as one (spec 3.1 — it must begin with '@')
looks exactly like a block that had nothing to say.
It is also where conformance C5 is discharged properly: warnings must
name the command that was skipped and say why, and distinguish "unknown
to the format" from "known but not supported by this build", because
the user's remedy differs.
The controls are built in code: the panel is a read-only report whose
whole content is generated, so a designer file would carry one memo and
a heading and add a second place to keep in step. The .fmx beside this
unit is therefore all but empty — but it must exist, because TFrame's
constructor calls InitInheritedComponent and raises EResNotFound for any
frame class with no form resource.
It computes nothing and it plots nothing, so ActiveAnalysisKey has no
entry for it: the shell's plot-styling and loaded-data bookkeeping key
off that name and correctly skip a panel that has neither. }
interface
uses
System.SysUtils, System.Classes, System.Types, System.UITypes,
FMX.Types, FMX.Controls, FMX.Forms, FMX.StdCtrls, FMX.Layouts,
FMX.Memo, FMX.Memo.Types, FMX.ScrollBox, FMX.Controls.Presentation,
uAnalysisTypes, uMetaExperiments,
Sim.Meta, Sim.Meta.Types, Sim.Meta.Model;
type
TFrameMetadata = class(TFrame)
private
FContext: IAnalysisContext;
FMemo: TMemo;
FHeading: TLabel;
FRefresh: TButton;
procedure DoRefreshClick(Sender: TObject);
procedure BuildUI;
procedure AppendExperiments(ALines: TStringList);
procedure AppendSkipped(ALines: TStringList);
procedure AppendDiagnostics(ALines: TStringList);
public
constructor Create(AOwner: TComponent); override;
procedure SetContext(const AContext: IAnalysisContext);
{ Re-render from whatever the shell currently holds. Cheap, so the
shell may call it on every re-parse. }
procedure Refresh;
end;
implementation
{$R *.fmx}
const
KIND_NAMES: array[TMetaExperimentKind] of string =
('time course', 'steady state', 'parameter scan');
constructor TFrameMetadata.Create(AOwner: TComponent);
begin
inherited;
BuildUI;
end;
procedure TFrameMetadata.BuildUI;
var
Bar: TLayout;
begin
Bar := TLayout.Create(Self);
Bar.Parent := Self;
Bar.Align := TAlignLayout.Top;
Bar.Height := 40;
FHeading := TLabel.Create(Self);
FHeading.Parent := Bar;
FHeading.Align := TAlignLayout.Client;
FHeading.Margins.Rect := RectF(8, 0, 4, 0);
FHeading.VertTextAlign := TTextAlign.Center;
FHeading.Text := 'Simulation metadata';
FRefresh := TButton.Create(Self);
FRefresh.Parent := Bar;
FRefresh.Align := TAlignLayout.Right;
FRefresh.Width := 80;
FRefresh.Margins.Rect := RectF(4, 7, 8, 7);
FRefresh.Text := 'Refresh';
FRefresh.OnClick := DoRefreshClick;
FMemo := TMemo.Create(Self);
FMemo.Parent := Self;
FMemo.Align := TAlignLayout.Client;
FMemo.Margins.Rect := RectF(8, 0, 8, 8);
FMemo.ReadOnly := True;
FMemo.WordWrap := False;
FMemo.ShowScrollBars := True;
end;
procedure TFrameMetadata.SetContext(const AContext: IAnalysisContext);
begin
FContext := AContext;
Refresh;
end;
procedure TFrameMetadata.DoRefreshClick(Sender: TObject);
begin
Refresh;
end;
procedure TFrameMetadata.Refresh;
var
Meta: TSimulationMetadata;
Lines: TStringList;
Info: TMetaInfoCommand;
begin
if (FContext = nil) or (FMemo = nil) then Exit;
Meta := FContext.Metadata;
Lines := TStringList.Create;
try
if (Meta = nil) or (not Meta.HasMetadata) then
begin
FHeading.Text := 'Simulation metadata — none in this model';
Lines.Add('This model has no simulation-metadata block.');
Lines.Add('');
Lines.Add('A block is an ordinary Antimony block comment whose first');
Lines.Add('non-whitespace character is ''@'':');
Lines.Add('');
Lines.Add(' /*');
Lines.Add(' @simulate: { timestart: 0, timeend: 50, points: 500 }');
Lines.Add(' @plot: { y: [S1, S2] }');
Lines.Add(' */');
Lines.Add('');
Lines.Add('Because it lives in a comment the model stays valid');
Lines.Add('Antimony, and tools that do not understand the block');
Lines.Add('ignore it.');
{ A block that was written but not recognised still produces a
diagnostic, so show those even here — that case is exactly why
this panel is worth having. }
AppendDiagnostics(Lines);
FMemo.Lines.Assign(Lines);
Exit;
end;
FHeading.Text := 'Simulation metadata';
Info := Meta.Meta;
if Info <> nil then
begin
if Info.Title <> '' then Lines.Add('Title: ' + Info.Title);
if Info.Author <> '' then Lines.Add('Author: ' + Info.Author);
if Info.Description <> '' then Lines.Add('Description: ' + Info.Description);
if Lines.Count > 0 then Lines.Add('');
end;
AppendExperiments(Lines);
AppendSkipped(Lines);
AppendDiagnostics(Lines);
FMemo.Lines.Assign(Lines);
finally
Lines.Free;
end;
end;
procedure TFrameMetadata.AppendExperiments(ALines: TStringList);
var
ASet: TMetaExperimentSet;
I: Integer;
E: TMetaExperiment;
P: TPlotCommand;
O: TOutputCommand;
begin
ASet := FContext.MetaExperiments;
if (ASet = nil) or (ASet.Count = 0) then
begin
ALines.Add('EXPERIMENTS');
ALines.Add(' (none — the block defines no simulate, scan or');
ALines.Add(' steadystate command)');
ALines.Add('');
Exit;
end;
ALines.Add('EXPERIMENTS');
ALines.Add('');
for I := 0 to ASet.Count - 1 do
begin
E := ASet[I];
ALines.Add(Format(' %s [%s]', [E.LabelText, KIND_NAMES[E.Kind]]));
if not E.Usable then
{ Named, with the reason. This is the C5 obligation, and it is the
whole point of keeping an unusable command rather than dropping
it. }
ALines.Add(' NOT USED: ' + E.Reason)
else if E.Task.SettingsSummary <> '' then
ALines.Add(' ' + E.Task.SettingsSummary);
for P in E.Plots do
ALines.Add(' plot: ' + P.SettingsSummary);
for O in E.Outputs do
ALines.Add(' output: ' + O.SettingsSummary);
if Length(E.SkippedPlots) > 0 then
ALines.Add(' note: Iridium has one plot surface and draws the ' +
'first plot only.');
ALines.Add('');
end;
end;
procedure TFrameMetadata.AppendSkipped(ALines: TStringList);
var
ASet: TMetaExperimentSet;
S: TMetaSkippedCommand;
begin
ASet := FContext.MetaExperiments;
if (ASet = nil) or (Length(ASet.Skipped) = 0) then Exit;
ALines.Add('NOT SUPPORTED BY THIS BUILD');
ALines.Add('');
{ The distinction that matters here is between a command the format
does not define (probably a typo) and one it does define that Iridium
cannot realise (try another tool) — the library words the reason
accordingly. }
for S in ASet.Skipped do
begin
ALines.Add(' ' + S.Display);
ALines.Add(' ' + S.Reason);
end;
ALines.Add('');
end;
procedure TFrameMetadata.AppendDiagnostics(ALines: TStringList);
var
Meta: TSimulationMetadata;
I: Integer;
begin
Meta := FContext.Metadata;
if (Meta = nil) or (Meta.Diagnostics.Count = 0) then Exit;
ALines.Add(Format('DIAGNOSTICS (%d error(s), %d warning(s))',
[Meta.Diagnostics.ErrorCount, Meta.Diagnostics.WarningCount]));
ALines.Add('');
{ Formatted by the library: 'file.ant(42,7): warning META0107: ...'.
The codes are the stable part — they are what to look up and what to
report — while the wording will keep improving. }
for I := 0 to Meta.Diagnostics.Count - 1 do
ALines.Add(' ' + Meta.Diagnostics.Format(I));
ALines.Add('');
end;