-
Notifications
You must be signed in to change notification settings - Fork 232
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
feat(interlink): console doc for private beta #4319
Open
RoRoJ
wants to merge
29
commits into
main
Choose a base branch
from
MTA-5337
base: main
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Open
Changes from all commits
Commits
Show all changes
29 commits
Select commit
Hold shift + click to select a range
72f60a8
feat(interlink): start concepts
RoRoJ 797d07f
feat(interlink): continue
RoRoJ 98918f0
fix(interlink): modifications
RoRoJ fb86d05
feat(interlink): continue
RoRoJ bdca2a1
fix(interlink): add links
RoRoJ d7e638d
fix(interlink): fixed links
RoRoJ f77e49d
fix(interlink): add more content
RoRoJ 477d842
feat(interlink): doc
RoRoJ a34433f
feat(interlink): private beta doc
RoRoJ 2800133
fix(interlink): add info
RoRoJ 4b0932a
Apply suggestions from code review
RoRoJ 70aa9a7
Apply suggestions from code review
RoRoJ 86687f3
Apply suggestions from code review
RoRoJ caa2423
Apply suggestions from code review
RoRoJ da28a0c
fix(interlink): change 10 working days to 10 days
RoRoJ a8756fc
Apply suggestions from code review
RoRoJ 843df6a
Apply suggestions from code review
RoRoJ 6b2d5e7
fix(interlink): add pairing key info
RoRoJ 14df830
feat(interlink): console doc
RoRoJ c0988c3
fix(interlink): add doc
RoRoJ 11db0ad
fix(interlink): continue doc
RoRoJ 4d49f4b
feat(interlink): continue doc
RoRoJ 5209610
feat(interlink): continue doc
RoRoJ 8a5555c
feat(interlink): first draft public beta
RoRoJ bd7a4c5
fix(interlink): changed provisioning doc
RoRoJ 2cab188
fix(interlink): add faq
RoRoJ 8ba3168
fix(interlink): rebase and change links
RoRoJ b41b452
fix(interlink): continue content
RoRoJ 6a46a84
fix(interlink): ready
RoRoJ File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file added
BIN
+53.9 KB
pages/interlink/how-to/assets/scaleway-interlink-overview-requesting.webp
Binary file not shown.
Binary file not shown.
Binary file not shown.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change | ||||
---|---|---|---|---|---|---|
@@ -0,0 +1,79 @@ | ||||||
--- | ||||||
meta: | ||||||
title: How to complete InterLink provisioning | ||||||
description: Learn how to complete the provisioning process for your Scaleway InterLink, to ensure your hosted connection between your on-premises infrastructure and Scaleway VPC is up and running as soon as possible. | ||||||
noindex: true | ||||||
content: | ||||||
h1: How to complete InterLink provisioning | ||||||
paragraph: Learn how to complete the provisioning process for your Scaleway InterLink, to ensure your hosted connection between your on-premises infrastructure and Scaleway VPC is up and running as soon as possible. | ||||||
dates: | ||||||
validation: 2024-12-09 | ||||||
posted: 2024-12-09 | ||||||
tags: interlink direct-connect provision hosted partner contact error | ||||||
categories: | ||||||
- network | ||||||
--- | ||||||
|
||||||
<Message type="important"> | ||||||
InterLink is currently in [Private Beta](https://www.scaleway.com/en/betas/), and only available to selected testers. | ||||||
</Message> | ||||||
|
||||||
After you have [ordered your InterLink](/interlink/how-to/order-interlink), further action is required on both the customer side and the [partner](/interlink/concepts/#partner) side before the InterLink is provisioned and ready for active use. This page walks you through the steps to take and how to deal with potential problems that could arise. | ||||||
|
||||||
<Lightbox src="scaleway-interlink-ordering.webp" alt="A four step flow chart shows the following steps: 1. User orders InterLink via Scaleway, 2. User requests InterLink from partner, 3. Partner accepts InterLink request, 4. Partner provisions InterLink." /> | ||||||
|
||||||
<Macro id="requirements" /> | ||||||
|
||||||
- A Scaleway account logged into the [console](https://console.scaleway.com) | ||||||
- [Owner](/iam/concepts/#owner) status or [IAM permissions](/iam/concepts/#permission) allowing you to perform actions in the intended Organization | ||||||
- [Ordered an InterLink](/interlink/how-to/order-interlink) | ||||||
|
||||||
## Contact partner to request InterLink | ||||||
|
||||||
After ordering the InterLink from Scaleway, you **must** contact your chosen partner to request that they provision the connection on their side. Scaleway is not able to automatically do this step for you. | ||||||
|
||||||
1. Click **InterLink** in the **Network** section of the [Scaleway console](https://console.scaleway.com) side menu. A listing of your InterLinks displays. | ||||||
|
||||||
2. Click on the InterLink that you want to finish provisioning. The InterLink's **Overview** page displays. | ||||||
|
||||||
<Lightbox src="scaleway-interlink-overview-requesting.webp" alt="A screen in the Scaleway console show's an overview of an InterLink's partner, location, region, bandwidth, creation date, pairing key, and IPv4/IPv6 connectivity status." /> | ||||||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more.
Suggested change
|
||||||
|
||||||
3. Note down the [pairing key](/interlink/concepts/#pairing-key) for your InterLink. This is a unique identification number which the partner will need in order to provision your InterLink. | ||||||
|
||||||
4. Contact your partner. After [creating your InterLink order](/interlink/how-to/order-interlink/), either their online portal URL, or their email address was displayed to you for this purpose. Use the relevant method to contact your partner, provide the pairing key, and request that they provision your InterLink from their side. | ||||||
|
||||||
<Message type="tip"> | ||||||
You can also use the [Get a partner](https://www.scaleway.com/en/developers/api/interlink/#path-partners-get-a-partner) endpoint in the API to get contact details and other information about your selected partner. | ||||||
</Message> | ||||||
|
||||||
Your InterLink will remain in `Requested` status until the partner responds to your request. | ||||||
|
||||||
## Wait for partner to accept InterLink request | ||||||
|
||||||
Once you have requested the InterLink from your partner, you must wait for them to respond to your request. There is no further action for you to take at this point. You can keep track of your InterLink's [status](/interlink/reference-content/statuses/) via the [InterLink listing](https://console.scaleway.com/interlink/links) in the Scaleway console. | ||||||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more.
Suggested change
|
||||||
|
||||||
<Lightbox src="scaleway-interlink-listing.webp" alt="A screen in the Scaleway console shows a listing of InterLinks, with the following information: name, status, partner, location, region and bandwidth." /> | ||||||
|
||||||
When the partner approves your request, the InterLink moves to `Provisioning` status. This means that the partner has agreed to facilitate your InterLink, and is now preparing the resources and configuration necessary to establish the physical connection. | ||||||
|
||||||
Your InterLink will remain in `Provisioning` status until this process has been completed. | ||||||
|
||||||
<Message type="important"> | ||||||
If your InterLink does not move to `Provisioning` status, you may see one of the following statuses: | ||||||
|
||||||
- `Refused`: The partner did not agree to provision your InterLink. Delete this InterLink resource, and contact your partner for more information. Consider re-ordering with a different partner. | ||||||
- `Expired`: Your InterLink order timed out: after 10 days, no response was received from the selected partner. Delete the InterLink resource, and create a new order if you wish to try again. | ||||||
</Message> | ||||||
|
||||||
## Partner provisions InterLink | ||||||
|
||||||
When the partner has finished provisioning your InterLink, it moves to `Active` status. This indicates that the physical link and necessary accompanying configuration has been completed on the partner's side, and your InterLink is ready for use. | ||||||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more.
Suggested change
|
||||||
|
||||||
You must still configure your InterLink by attaching it to a VPC, attaching an allowed routes list, and activating route propagation, before traffic can flow over the InterLink. For help with these steps, see our documentation on [How to configure your InterLink](/interlink/reference-content/configuring/). | ||||||
|
||||||
<Message type="important"> | ||||||
If you see a `Limited connectivity` status next to your InterLink on the [listing page](https://console.scaleway.com/interlink/links), this indicates that the partner provisioned your InterLink, but either IPv4 or IPv6 connectivity is down. Similarly, a `Down` status indicates the InterLink is provisioned, but both IPv4 **and** IPv6 connectivity are down. Open a Scaleway support ticket, or contact your partner for assistance. | ||||||
|
||||||
A `Locked` status indicates, again, that the InterLink was provisioned, but Scaleway Trust and Safety have locked the resource. No actions are possible from you as a user: you should open a support ticket for help and information. | ||||||
</Message> | ||||||
|
Oops, something went wrong.
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.